7709 N WILBUR AVE 91335

Certificate Information: 7709 N WILBUR AVE 91335

Application / Permit
22010-20000-03867
Plan Check / Job No.
B22VN11876
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
ePlan NEW 40'-2" X 56'-6" IRREGULAR SHAPED 1-STORY SFD W/ 1-CAR GARAGE AND 8' X 18'-8" TRELLIS PATIO AT EASTERN PORTION OF PARCEL A per SB9 Two-Unit Development and Urban Lot Split Ca Govt Code 68582.21 and 66411.7. NFPA 13D FIRE SPRINKLERS THROUGHOUT. ALL WORK PER ENGINEERING.
Permit Issued
Issued on 6/4/2025
Issuing Office
Current Status
Issued on 6/4/2025
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 8/3/2022 APPLICANT
Assigned to Plan Check Engineer 8/25/2022 RAPHAEL ROSAS
Corrections Issued 9/2/2022 RAPHAEL ROSAS
Quality Review Completed 9/8/2022 STEVEN KIM
Applicant returned to address corrections 2/13/2025 RAPHAEL ROSAS
Applicant returned to address corrections 2/18/2025 RAPHAEL ROSAS
Plan Check Approved 2/27/2025 RAPHAEL ROSAS
Plan Check Approved 4/22/2025 RAPHAEL ROSAS
Plan Check Approved 5/27/2025 RAPHAEL ROSAS
Issued 6/4/2025 APPLICANT

Permit Application Clearance Information

Permit Cleared 3/5/2024 LEE GUILBEAUX
Eng Process Fee Ord 176,300 Cleared 3/6/2024 LEE GUILBEAUX
Address approval Cleared 5/13/2024 LEE GUILBEAUX
Trees in Parkway Cleared 5/13/2024 ADALBERTO VERA
Hydrant and Access approval Cleared 6/10/2024 KURT CORRAL
Sewer availability Cleared 6/13/2024 LEE GUILBEAUX
Low Impact Development Cleared 8/22/2024 LUIS LUVANO
"Q" conditions Cleared 1/29/2025 NELSON RODRIGUEZ
Miscellaneous Cleared 1/29/2025 NELSON RODRIGUEZ
Miscellaneous Cleared 1/29/2025 NELSON RODRIGUEZ
Miscellaneous Cleared 1/29/2025 NELSON RODRIGUEZ
Roof/Waste drainage to street Cleared 1/29/2025 LEE GUILBEAUX
Senate Bill 9 Cleared 1/29/2025 NELSON RODRIGUEZ
ZA Case Cleared 1/29/2025 NELSON RODRIGUEZ

Contact Information

Contractor Owner-Builder       ,

Inspector Information

ARUTYUN MADATYAN, (818) 774-4307 Office Hours: 7:00-8:00 AM MON-FRI
JUAN ALVARADO, (818) 774-4307 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Underground Mechanical 7/14/2025 Approved JUAN ALVARADO
Footing/Foundation/Slab 7/21/2025 Approved JUAN ALVARADO
Floor/Roof Diaphrgm/Shear Wall 8/13/2025 Approved JUAN ALVARADO
ELECTRICAL-Rough 8/26/2025 Approved JUAN ALVARADO
Gas Test 8/26/2025 Approved JUAN ALVARADO
HVAC-Rough 8/26/2025 Approved JUAN ALVARADO
PLUMBING-Rough 8/26/2025 Not Ready for Inspection JUAN ALVARADO
BUILDING-Rough-Frame 8/28/2025 Approved JUAN ALVARADO
Green Building Rough 8/28/2025 Approved JUAN ALVARADO
Interior/Exterior Lathing 8/28/2025 Approved JUAN ALVARADO
PLUMBING-Rough 8/28/2025 Approved JUAN ALVARADO
Verify Sprinkler Sign Off 8/28/2025 Approved JUAN ALVARADO
Drywall Nailing 9/12/2025 Not Ready for Inspection JUAN ALVARADO
Insulation 9/12/2025 Approved JUAN ALVARADO
Drywall Nailing 9/16/2025 Approved JUAN ALVARADO
Interior/Exterior Lathing 9/16/2025 Approved JUAN ALVARADO
Sewer 11/4/2025 Approved ARUTYUN MADATYAN