18037 W TRIBUNE ST 91344

Certificate Information: 18037 W TRIBUNE ST 91344

Application / Permit
22010-20000-03795
Plan Check / Job No.
B22VN11636
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
(N) TWO-STORY 30' x 19' ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) and (d) ALL WORK PER ENGINEERING
Permit Issued
Issued on 1/3/2023
Issuing Office
Current Status
CofO Issued on 7/3/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 7/28/2022 APPLICANT
Assigned to Plan Check Engineer 8/18/2022 SEWADA ZADOORIAN MILAGARDI
Corrections Issued 8/22/2022 SEWADA ZADOORIAN MILAGARDI
Quality Review Completed 8/29/2022 OMID HEDAYAT
Building Plans Picked Up 8/30/2022 APPLICANT
Plan Check Approved 1/3/2023 SEWADA ZADOORAN MILAGARDI
Issued 1/3/2023 APPLICANT
CofO in Progress 6/29/2023 STEVEN BACK
Permit Finaled 7/3/2023 JOHN JANSON
CofO Issued 7/3/2023 JOHN JANSON
Permit Finaled 7/3/2023 JOHN JANSON

Permit Application Clearance Information

Address approval Cleared 9/21/2022 COLIN LOREDO
Sewer availability Cleared 9/21/2022 COLIN LOREDO
Eng Process Fee Ord 176,300 Cleared 10/31/2022 COLIN LOREDO
Hydrant and Access approval Cleared 11/13/2022 JOHN CONNEALLY
Miscellaneous Cleared 12/15/2022 ASHLEY RODARTE
Low Impact Development Cleared 12/22/2022 ERNEST TSE
Roof/Waste drainage to street Cleared 12/22/2022 COLIN LOREDO
Miscellaneous Cleared 12/27/2022 COLIN LOREDO

Contact Information

Contractor Owner-Builder       ,
Engineer Grigoryan,, Souren; Lic. No.: C93320 6506 TEESDALE AVE      NORTH HOLLYWOOD, CA 91606

Inspector Information

JEFFREY PARD, (818) 774-4312 Office Hours: 7:00-8:00 AM MON-FRI
STEVEN BACK, (818) 774-4312 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 1/26/2023 Corrections Issued STEVEN BACK
Sewer 1/26/2023 Approved STEVEN BACK
Underground Mechanical 1/26/2023 Approved STEVEN BACK
Footing/Foundation/Slab 1/30/2023 Approved STEVEN BACK
Floor/Roof Diaphrgm/Shear Wall 2/6/2023 Partial Approval STEVEN BACK
Pre-Inspection 2/6/2023 Partial Inspection MORRIS JACKSON
Floor/Roof Diaphrgm/Shear Wall 2/27/2023 Corrections Issued STEVEN BACK
Deputy Wood Construction 2/28/2023 Conditional Approval STEVEN BACK
ELECTRICAL-Rough 3/3/2023 Approved JUSTIN HAWLEY
Final 3/3/2023 Corrections Issued STEVEN BACK
Floor/Roof Diaphrgm/Shear Wall 3/3/2023 Not Ready for Inspection JUSTIN HAWLEY
PLUMBING-Rough 3/3/2023 Approved STEVEN BACK
Special/Order Compliance 3/3/2023 Approved STEVEN BACK
Special/Order Compliance 3/6/2023 Approved STEVEN BACK
BUILDING-Rough-Frame 3/13/2023 Approved STEVEN BACK
Floor/Roof Diaphrgm/Shear Wall 3/13/2023 Approved STEVEN BACK
Green Building Rough 3/13/2023 Approved STEVEN BACK
HVAC-Rough 3/13/2023 Approved STEVEN BACK
Insulation 3/17/2023 Approved STEVEN BACK
Interior/Exterior Lathing 3/17/2023 Approved STEVEN BACK
Shower Pan 3/17/2023 Approved STEVEN BACK
Drywall Nailing 3/29/2023 Approved JOHN KIDWELL
Special/Order Compliance 3/29/2023 Corrections Issued JOHN KIDWELL
Final 6/23/2023 Corrections Issued STEVEN BACK
Green Building Final 6/23/2023 Approved STEVEN BACK
SGSOV-Seismic Gas S/O Valve 6/23/2023 SGSOV Not Ready STEVEN BACK
Smoke Detectors 6/23/2023 Corrections Issued STEVEN BACK
Final 6/29/2023 OK to Issue CofO STEVEN BACK
SGSOV-Seismic Gas S/O Valve 6/29/2023 SGSOV Approved STEVEN BACK
Service/Power Release 6/29/2023 Approved STEVEN BACK
Smoke Detectors 6/29/2023 Approved STEVEN BACK