20713 W BRYANT ST 91306
Certificate Information: 20713 W BRYANT ST 91306
- Application / Permit
- 22010-20000-03777
- Plan Check / Job No.
- B22VN11587
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- NEW 56'4" X 29'6" IREEGULAR SHAPED DETACHED ACCESSORY DWELLING UNIT AS PER LAMC 12.22.A.33 (C) AND (D), NFPA-13D FIRE SPRINKELRS REQUIRED , ALL WORK PER ENGINEERING
- Permit Issued
- Issued on 9/21/2022
- Issuing Office
- Current Status
- CofO Issued on 5/31/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 7/28/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 8/11/2022 | RARES BODEA |
| Corrections Issued | 8/15/2022 | RARES BODEA |
| Quality Review Completed | 8/18/2022 | STEVEN KIM |
| Building Plans Picked Up | 8/19/2022 | APPLICANT |
| Plan Check Approved | 9/21/2022 | RARES BODEA |
| Issued | 9/21/2022 | APPLICANT |
| CofO in Progress | 4/5/2023 | CHRIS CHRISTENSEN |
| No Progress | 5/9/2023 | JOHN JANSON |
| CofO in Progress | 5/31/2023 | CHRIS CHRISTENSEN |
| Permit Finaled | 5/31/2023 | JOHN JANSON |
| CofO Issued | 5/31/2023 | JOHN JANSON |
| Permit Finaled | 5/31/2023 | JOHN JANSON |
Permit Application Clearance Information
| Address approval | Cleared | 8/25/2022 | CARLOS AGUILERA |
| Eng Process Fee Ord 176,300 | Cleared | 8/25/2022 | CARLOS AGUILERA |
| Sewer availability | Cleared | 8/25/2022 | CARLOS AGUILERA |
| Miscellaneous | Cleared | 8/29/2022 | DANG NGUYEN |
| Senate Bill 9 | Cleared | 8/29/2022 | DANG NGUYEN |
| Hydrant and Access approval | Cleared | 9/13/2022 | RUEL COLE |
| Low Impact Development | Cleared | 9/20/2022 | ANTHONY VARGAS |
| Roof/Waste drainage to street | Cleared | 9/20/2022 | MEGAN GODINEZ |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Wang,, Hongyu; Lic. No.: C72679 | 8887 W FALMINGO RD STE 101 LAS VEGAS, NV 89147 |
Inspector Information
| JEFFREY HARTLINE, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
| CHRIS CHRISTENSEN, (818) 774-4320 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 9/23/2022 | Approved | CHRIS CHRISTENSEN |
| Floor/Roof Diaphrgm/Shear Wall | 11/2/2022 | Partial Approval | CHRIS CHRISTENSEN |
| ELECTRICAL-Rough | 11/9/2022 | Not Ready for Inspection | CHRIS CHRISTENSEN |
| PLUMBING-Rough | 11/9/2022 | Approved | CHRIS CHRISTENSEN |
| Deputy Wood Construction | 11/18/2022 | Conditional Approval | CHRIS CHRISTENSEN |
| BUILDING-Rough-Frame | 11/21/2022 | Partial Approval | CHRIS CHRISTENSEN |
| ELECTRICAL-Rough | 11/21/2022 | Approved | CHRIS CHRISTENSEN |
| HVAC-Rough | 11/21/2022 | Approved | CHRIS CHRISTENSEN |
| PLUMBING-Rough | 11/21/2022 | Approved | CHRIS CHRISTENSEN |
| BUILDING-Rough-Frame | 12/2/2022 | Conditional Approval | CHRIS CHRISTENSEN |
| Green Building Rough | 12/2/2022 | Approved | CHRIS CHRISTENSEN |
| Insulation | 12/2/2022 | Approved | CHRIS CHRISTENSEN |
| Interior/Exterior Lathing | 12/2/2022 | Partial Approval | CHRIS CHRISTENSEN |
| Verify Sprinkler Sign Off | 12/2/2022 | Approved | CHRIS CHRISTENSEN |
| Drywall Nailing | 12/12/2022 | Approved | CHRIS CHRISTENSEN |
| Interior/Exterior Lathing | 1/3/2023 | Partial Approval | CHRIS CHRISTENSEN |
| ELECTRICAL-Final | 2/1/2023 | Approved | CHRIS CHRISTENSEN |
| BUILDING-Rough-Frame | 3/8/2023 | Approved | CHRIS CHRISTENSEN |
| Final | 3/8/2023 | Not Ready for Inspection | CHRIS CHRISTENSEN |
| Green Building Final | 3/8/2023 | Approved | CHRIS CHRISTENSEN |
| HVAC-Final | 3/8/2023 | Corrections Issued | CHRIS CHRISTENSEN |
| PLUMBING-Final | 3/8/2023 | Corrections Issued | CHRIS CHRISTENSEN |
| Service/Power Release | 3/8/2023 | Not Ready for Inspection | CHRIS CHRISTENSEN |
| Smoke Detectors | 3/8/2023 | Approved | CHRIS CHRISTENSEN |
| Special/Order Compliance | 3/8/2023 | Approved | DAVID SCANTLIN |
| Final | 3/13/2023 | Corrections Issued | CHRIS CHRISTENSEN |
| HVAC-Final | 3/13/2023 | Approved | CHRIS CHRISTENSEN |
| PLUMBING-Final | 3/13/2023 | Approved | CHRIS CHRISTENSEN |
| SGSOV-Seismic Gas S/O Valve | 3/13/2023 | SGSOV Approved | CHRIS CHRISTENSEN |
| Service/Power Release | 3/13/2023 | Not Required | CHRIS CHRISTENSEN |
| Final | 4/4/2023 | OK to Issue CofO | CHRIS CHRISTENSEN |
| Service/Power Release | 4/26/2023 | Corrections Issued | CHRIS CHRISTENSEN |
| Service/Power Release | 5/24/2023 | Approved | JOHN KIDWELL |