5112 N SHEARIN AVE 90041
Certificate Information: 5112 N SHEARIN AVE 90041
- Application / Permit
- 22010-20000-03334
- Plan Check / Job No.
- B22VN10454
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- NEW 45'-7" X 56'-8" IRREGULAR SHAPED 2-STORY SFD W/ ATTACHED 2-CAR GARAGE AND PATIO COVER. NFPA 13D FIRE SPRINKLERS THROUGHOUT. ALL WORK PER ENGINEERING. - 1 OF 2
- Permit Issued
- Issued on 4/28/2023
- Issuing Office
- Valley
- Current Status
- CofO Issued on 11/23/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 7/8/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 8/4/2022 | RAPHAEL ROSAS |
| Corrections Issued | 8/8/2022 | RAPHAEL ROSAS |
| Quality Review Completed | 8/12/2022 | STEVEN KIM |
| Building Plans Picked Up | 8/15/2022 | APPLICANT |
| Applicant returned to address corrections | 11/3/2022 | RAPHAEL ROSAS |
| Applicant returned to address corrections | 3/1/2023 | RAPHAEL ROSAS |
| Plan Check Approved | 4/6/2023 | RAPHAEL ROSAS |
| Issued | 4/28/2023 | APPLICANT |
| CofO in Progress | 11/13/2024 | ROY SPAULDING |
| Permit Finaled | 11/23/2024 | DEROLD HAUFF |
| Permit Finaled | 11/23/2024 | DEROLD HAUFF |
| CofO Issued | 11/23/2024 | DEROLD HAUFF |
Permit Application Clearance Information
| Address approval | Cleared | 9/6/2022 | CINDY QI |
| Eng Process Fee Ord 176,300 | Cleared | 9/8/2022 | CINDY QI |
| Low Impact Development | Cleared | 10/31/2022 | ROGELIO CORTES |
| Permit | Cleared | 11/1/2022 | CINDY QI |
| Roof/Waste drainage to street | Cleared | 11/1/2022 | CINDY QI |
| Sewer availability | Cleared | 11/22/2022 | CINDY QI |
| Hydrant and Access approval | Cleared | 2/8/2023 | KURT CORRAL |
| Trees in Parkway | Cleared | 2/22/2023 | ADALBERTO VERA |
| GPI Written Notices | Cleared | 4/6/2023 | RAPHAEL ROSAS |
| Grading Pre-Inspection | Cleared | 4/6/2023 | RAPHAEL ROSAS |
Contact Information
| Contractor | Opus Builders Inc; Lic. No.: 1059646-B | 5244 VINELAND AVENUE NORTH HOLLYWOOD, CA 91601 |
| Engineer | Standley,, Craig Erick; Lic. No.: C87675 | 60 VIA CARATAMA SAN CLEMENTE, CA 92673 |
Inspector Information
| RONNIE MEDINA, (213) 469-5852 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 6/7/2023 | Partial Approval | CRAIG VAUGHAN |
| Pre-Inspection | 6/7/2023 | Approved | CRAIG VAUGHAN |
| Footing/Foundation/Slab | 6/16/2023 | Approved | BRIAN SULLIVAN |
| Deputy Reinf. Concrete | 6/22/2023 | Conditional Approval | BRIAN SULLIVAN |
| Floor/Roof Diaphrgm/Shear Wall | 7/3/2023 | Partial Approval | JEFFREY MEAD |
| Interior/Exterior Lathing | 10/27/2023 | Approved | JOSH MEISTER |
| BUILDING-Rough-Frame | 11/6/2023 | Not Ready for Inspection | CRAIG VAUGHAN |
| ELECTRICAL-Rough | 11/6/2023 | Not Ready for Inspection | CRAIG VAUGHAN |
| Green Building Rough | 11/6/2023 | Approved | CRAIG VAUGHAN |
| HVAC-Rough | 11/6/2023 | Not Ready for Inspection | CRAIG VAUGHAN |
| PLUMBING-Rough | 11/6/2023 | Not Ready for Inspection | CRAIG VAUGHAN |
| Verify Sprinkler Sign Off | 11/6/2023 | Approved | CRAIG VAUGHAN |
| ELECTRICAL-Rough | 11/7/2023 | Partial Approval | CRAIG VAUGHAN |
| HVAC-Rough | 11/7/2023 | Partial Approval | CRAIG VAUGHAN |
| PLUMBING-Rough | 11/7/2023 | Approved | CRAIG VAUGHAN |
| BUILDING-Rough-Frame | 11/9/2023 | Approved | CRAIG VAUGHAN |
| ELECTRICAL-Rough | 11/9/2023 | Approved | CRAIG VAUGHAN |
| HVAC-Rough | 11/9/2023 | Approved | CRAIG VAUGHAN |
| Pre-Inspection | 11/9/2023 | Approved | CRAIG VAUGHAN |
| Wood Frame | 11/9/2023 | Approved | CRAIG VAUGHAN |
| Insulation | 11/20/2023 | Approved | ROY SPAULDING |
| Drywall Nailing | 11/29/2023 | Approved | CRAIG VAUGHAN |
| HVAC-Rough | 12/12/2023 | Approved | CRAIG VAUGHAN |
| Interior/Exterior Lathing | 12/12/2023 | Approved | CRAIG VAUGHAN |
| Shower Pan | 12/12/2023 | Not Ready for Inspection | CRAIG VAUGHAN |
| Shower Pan | 12/19/2023 | Approved | BRENDAN MORELLI |
| Special/Order Compliance | 5/23/2024 | Approved | CRAIG VAUGHAN |
| Special/Order Compliance | 6/12/2024 | Partial Inspection | CRAIG VAUGHAN |
| Pre-Inspection | 10/29/2024 | Not Ready for Inspection | ROY SPAULDING |
| Final | 10/30/2024 | Not Ready for Inspection | ROY SPAULDING |
| Green Building Final | 10/30/2024 | Not Ready for Inspection | ROY SPAULDING |
| SGSOV-Seismic Gas S/O Valve | 10/30/2024 | SGSOV Not Ready | ROY SPAULDING |
| Service/Power Release | 10/30/2024 | Not Ready for Inspection | ROY SPAULDING |
| Smoke Detectors | 10/30/2024 | Not Ready for Inspection | ROY SPAULDING |
| Final | 11/6/2024 | OK to Issue CofO | ROY SPAULDING |
| Green Building Final | 11/6/2024 | Approved | ROY SPAULDING |
| SGSOV-Seismic Gas S/O Valve | 11/6/2024 | SGSOV Approved | ROY SPAULDING |
| Service/Power Release | 11/6/2024 | Approved | ROY SPAULDING |
| Smoke Detectors | 11/6/2024 | Approved | ROY SPAULDING |