5842 N SATSUMA AVE 91601
Certificate Information: 5842 N SATSUMA AVE 91601
- Application / Permit
- 22010-20000-02967
- Plan Check / Job No.
- B22VN09251
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- eplan NEW DETACHED ADU PER LAMC 12.22 A.33 (c)(d)
- Permit Issued
- Issued on 10/10/2024
- Issuing Office
- Current Status
- CofO Issued on 5/2/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 6/21/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 6/29/2022 | KHUONG TRUONG |
| Corrections Issued | 6/30/2022 | KHUONG TRUONG |
| Applicant returned to address corrections | 8/5/2022 | KHUONG TRUONG |
| Plan Check Approved | 11/17/2022 | KHUONG TRUONG |
| Issued | 10/10/2024 | APPLICANT |
| CofO in Progress | 3/28/2025 | JOSE AVILA |
| Permit Finaled | 5/2/2025 | RUBEN SALAS |
| CofO Issued | 5/2/2025 | RUBEN SALAS |
| Permit Finaled | 5/2/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 7/20/2022 | MEGAN GODINEZ |
| Eng Process Fee Ord 176,300 | Cleared | 9/12/2022 | MEGAN GODINEZ |
| Sewer availability | Cleared | 9/12/2022 | MEGAN GODINEZ |
| Construction near power lines | Cleared | 9/30/2022 | RIDWAN HARDY |
| Low Impact Development | Cleared | 11/9/2022 | ERNEST TSE |
| Roof/Waste drainage to street | Cleared | 11/16/2022 | JOHN LIN |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| GAREN HAYRAPETYAN, (818) 374-1171 | Office Hours: 7:00-8:00 AM MON-FRI |
| ROBERTO PALACIOS-LOPEZ, (818) 374-1171 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 10/15/2024 | Corrections Issued | JOSE AVILA |
| Excavation/Setback/Form/Re-Bar | 10/18/2024 | Approved | JOSE AVILA |
| Excavation/Setback/Form/Re-Bar | 10/22/2024 | Approved | JOSE AVILA |
| Excavation/Setback/Form/Re-Bar | 10/25/2024 | Corrections Issued | JOSE AVILA |
| Floor/Roof Diaphrgm/Shear Wall | 11/5/2024 | Corrections Issued | JOSE AVILA |
| Floor/Roof Diaphrgm/Shear Wall | 11/6/2024 | Partial Approval | JOSE AVILA |
| BUILDING-Rough-Frame | 11/20/2024 | Approved | JOSE AVILA |
| ELECTRICAL-Rough | 11/20/2024 | Approved | JOSE AVILA |
| Green Building Rough | 11/20/2024 | Approved | JOSE AVILA |
| HVAC-Rough | 11/20/2024 | Approved | JOSE AVILA |
| PLUMBING-Rough | 11/20/2024 | Approved | JOSE AVILA |
| Sewer | 11/20/2024 | Approved | JOSE AVILA |
| Verify Sprinkler Sign Off | 11/20/2024 | Approved | JOSE AVILA |
| Insulation | 11/27/2024 | Approved | CHRISTOPHER ROJAS |
| Interior/Exterior Lathing | 11/27/2024 | Partial Approval | CHRISTOPHER ROJAS |
| Drywall Nailing | 12/10/2024 | Approved | JOSE AVILA |
| PLUMBING-Final | 2/24/2025 | Approved | JOSE AVILA |
| ELECTRICAL-Final | 3/14/2025 | Approved | JOSE AVILA |
| Service/Power Release | 3/14/2025 | Approved | JOSE AVILA |
| Service/Power Release | 3/27/2025 | Approved | JOSE AVILA |
| Final | 3/28/2025 | OK to Issue CofO | JOSE AVILA |
| Footing/Foundation/Slab | 3/28/2025 | Approved | JOSE AVILA |
| Green Building Final | 3/28/2025 | Approved | JOSE AVILA |
| Smoke Detectors | 3/28/2025 | Approved | JOSE AVILA |