17144 W GAULT ST 91406
Certificate Information: 17144 W GAULT ST 91406
- Application / Permit
- 22010-20000-02427
- Plan Check / Job No.
- B22VN07299
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (22) Storage Building for Household Goods
- Work Description
- ePlan: (N) DETACHED SHED ACCESSORY BUILDING
- Permit Issued
- Issued on 12/23/2022
- Issuing Office
- Current Status
- Issued on 12/23/2022
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 5/13/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 5/27/2022 | DANIEL YIP |
| Corrections Issued | 6/1/2022 | DANIEL YIP |
| Quality Review Completed | 6/22/2022 | MICHAEL PEREZ |
| Applicant returned to address corrections | 9/22/2022 | DANIEL YIP |
| Plan Check Approved | 11/9/2022 | DANIEL YIP |
| Issued | 12/23/2022 | APPLICANT |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 10/12/2022 | COLIN LOREDO |
| Roof/Waste drainage to street | Cleared | 10/12/2022 | COLIN LOREDO |
| Construction near power lines | Cleared | 11/5/2022 | RIDWAN HARDY |
Contact Information
| Contractor | Tuff Shed Inc; Lic. No.: 661664-B | 1777 S HARRISON STREET SUITE 600 DENVER, CO 80210 |
| Engineer | Wills,, Richard Jon; Lic. No.: NA67927 | , |
Inspector Information
| JON MCHUGH, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
| IVAN SARABIA, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 2/6/2023 | Corrections Issued | SEAN HAUPT |
| Footing/Foundation/Slab | 2/9/2023 | Approved | JON MCHUGH |
| Floor/Roof Diaphrgm/Shear Wall | 2/21/2023 | Partial Approval | JON MCHUGH |
| Verify Sprinkler Sign Off | 2/21/2023 | Approved | JON MCHUGH |
| Wood Frame | 2/21/2023 | Not Ready for Inspection | JON MCHUGH |
| Wood Frame | 3/8/2023 | Corrections Issued | JON MCHUGH |
| Interior/Exterior Lathing | 3/24/2023 | Not Ready for Inspection | JON MCHUGH |
| Pre-Inspection | 3/24/2023 | Approved | JON MCHUGH |
| Interior/Exterior Lathing | 4/5/2023 | Approved | JON MCHUGH |
| BUILDING-Rough-Frame | 4/20/2023 | Approved | JON MCHUGH |
| Drywall Nailing | 4/20/2023 | No Access for Inspection | JON MCHUGH |
| Final | 4/20/2023 | Corrections Issued | JON MCHUGH |
| SGSOV-Seismic Gas S/O Valve | 4/20/2023 | SGSOV Approved | JON MCHUGH |
| Service/Power Release | 4/20/2023 | Not Required | JON MCHUGH |
| Smoke Detectors | 4/20/2023 | Corrections Issued | JON MCHUGH |
| Drywall Nailing | 4/25/2023 | Approved | JON MCHUGH |
| Final | 4/25/2023 | Corrections Issued | JON MCHUGH |
| Smoke Detectors | 4/25/2023 | Approved | JON MCHUGH |