12261 W MONTAGUE ST 1-4 91331
Certificate Information: 12261 W MONTAGUE ST 1-4 91331
- Application / Permit
- 22010-20000-02184
- Plan Check / Job No.
- B22VN06561
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- Commercial
- Primary Use
- (22) Warehouse
- Work Description
- NEW 196-8" X 93'-4" WAREHOUSE BUILDING (4 Tenants) ALL WORK PER ENGINEERING TYPE IIIB CONSTRUCTION, NFPA 13 THROUGHOUT.
- Permit Issued
- Issued on 9/15/2023
- Issuing Office
- Valley
- Current Status
- Issued on 9/15/2023
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 4/29/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 5/26/2022 | SEWADA ZADOORIAN MILAGARDI |
| Green Plans Picked Up | 5/27/2022 | APPLICANT |
| Corrections Issued | 6/6/2022 | SEWADA ZADOORIAN MILAGARDI |
| Quality Review Completed | 6/6/2022 | OMID HEDAYAT |
| Building Plans Picked Up | 6/8/2022 | APPLICANT |
| Disabled Access Plans Picked Up | 6/8/2022 | APPLICANT |
| Applicant returned to address corrections | 1/6/2023 | SEWADA ZADOORIAN MILAGARDI |
| Applicant returned to address corrections | 1/23/2023 | SEWADA ZADOORIAN MILAGARDI |
| Applicant returned to address corrections | 2/23/2023 | SEWADA ZADOORIAN MILAGARDI |
| Applicant returned to address corrections | 7/11/2023 | SEWADA ZADOORIAN MILAGARDI |
| Plan Check Approved | 7/31/2023 | SEWADA ZADOORAN MILAGARDI |
| Issued | 9/15/2023 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 6/15/2022 | CARLOS AGUILERA |
| Eng Process Fee Ord 176,300 | Cleared | 6/16/2022 | CARLOS AGUILERA |
| Sewer availability | Cleared | 6/16/2022 | CARLOS AGUILERA |
| Trees in Parkway | Cleared | 6/28/2022 | ADALBERTO VERA |
| ZA Case | Cleared | 8/18/2022 | NATHAN ROMINE |
| Green Code | Cleared | 9/2/2022 | MICHAEL AYERS |
| Clean Up Green Up | Cleared | 9/7/2022 | NATHAN ROMINE |
| Prkng lot landscape/Water mgmt | Cleared | 9/7/2022 | NATHAN ROMINE |
| DAS Clearance | Cleared | 9/8/2022 | SEWADA ZADOORAN MILAGARDI |
| ZI | Cleared | 9/22/2022 | NATHAN ROMINE |
| "Q" conditions | Cleared | 11/17/2022 | NATHAN ROMINE |
| Low Impact Development | Cleared | 12/21/2022 | ANDRES COVARRUBIAS |
| Roof/Waste drainage to street | Cleared | 12/22/2022 | CARLOS AGUILERA |
| Highway dedication | Cleared | 4/5/2023 | LEE GUILBEAUX |
| Permit | Cleared | 6/12/2023 | CARLOS AGUILERA |
| "T" removal | Cleared | 7/19/2023 | NATHAN ROMINE |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Kardjian,, Vahe Matios; Lic. No.: C40821 | 1112 W BURBANK BLVD STE 301 BURBANK, CA 91506 |
| Engineer | Sosnowski,, Christopher John; Lic. No.: C53660 | 2117 S. 48TH ST SUITE 103 TEMPE, AZ 85281 |
Inspector Information
| JOHN KITCKO, (818) 374-1109 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 12/7/2023 | Partial Approval | DANNY RODRIGUEZ |
| Footing/Foundation/Slab | 12/12/2023 | Partial Approval | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 12/14/2023 | Conditional Approval | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 12/15/2023 | Approved | DANNY RODRIGUEZ |
| Green Building Rough | 12/15/2023 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Reinforced Masonry Frame | 12/15/2023 | Partial Approval | DANNY RODRIGUEZ |
| Verify Sprinkler Sign Off | 12/15/2023 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 12/18/2023 | Approved | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 12/19/2023 | Approved | DANNY RODRIGUEZ |
| Green Building Rough | 12/19/2023 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Pre-Inspection | 12/19/2023 | Partial Approval | DANNY RODRIGUEZ |
| Verify Sprinkler Sign Off | 12/19/2023 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Wood Frame | 12/19/2023 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 12/20/2023 | No Access for Inspection | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 12/21/2023 | No Access for Inspection | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 12/26/2023 | Approved | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 12/27/2023 | Approved | DANNY RODRIGUEZ |
| Green Building Rough | 12/27/2023 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Reinforced Masonry Frame | 12/27/2023 | Partial Approval | DANNY RODRIGUEZ |
| Verify Sprinkler Sign Off | 12/27/2023 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 12/28/2023 | Conditional Approval | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 12/29/2023 | Conditional Approval | JOHN KITCKO |
| Reinforced Concrete Frame | 1/2/2024 | Partial Approval | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 1/4/2024 | Approved | DANNY RODRIGUEZ |
| Green Building Rough | 1/4/2024 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Reinforced Masonry Frame | 1/4/2024 | Partial Approval | DANNY RODRIGUEZ |
| Verify Sprinkler Sign Off | 1/4/2024 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 1/5/2024 | Conditional Approval | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 1/8/2024 | Conditional Approval | DANNY RODRIGUEZ |
| Deputy Reinf. Masonry | 1/9/2024 | Conditional Approval | JEFFREY DURAN |
| Deputy Reinf. Masonry | 1/10/2024 | Approved | DANNY RODRIGUEZ |
| Green Building Rough | 1/10/2024 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Reinforced Masonry Frame | 1/10/2024 | Partial Approval | DANNY RODRIGUEZ |
| Verify Sprinkler Sign Off | 1/10/2024 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Deputy Wood Construction | 1/25/2024 | Conditional Approval | DANNY RODRIGUEZ |
| Floor/Roof Diaphrgm/Shear Wall | 1/25/2024 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Green Building Rough | 1/25/2024 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Verify Sprinkler Sign Off | 1/25/2024 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Floor/Roof Diaphrgm/Shear Wall | 1/26/2024 | Partial Approval | DANNY RODRIGUEZ |
| Special/Order Compliance | 7/11/2024 | Not Ready for Inspection | DANNY RODRIGUEZ |
| Excavation/Setback/Form/Re-Bar | 1/14/2025 | Not Ready for Inspection | DANNY RODRIGUEZ |