11849 W SATICOY ST 91605

Certificate Information: 11849 W SATICOY ST 91605

Application / Permit
22010-20000-01958
Plan Check / Job No.
B22VN05853
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
(N) 2 STORY 31 ' X 21' ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) and (d) ALL WORK PER ENGINEERING “The LID clearance has been deferred. Approval for LID requirements shall be obtained from LASAN prior to the issuance of the Certificate of Occupancy.”
Permit Issued
Issued on 10/11/2022
Issuing Office
Valley
Current Status
CofO Issued on 8/7/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 4/26/2022 APPLICANT
Assigned to Plan Check Engineer 5/19/2022 SEWADA ZADOORIAN MILAGARDI
Corrections Issued 5/25/2022 SEWADA ZADOORIAN MILAGARDI
Quality Review Completed 5/27/2022 OMID HEDAYAT
Building Plans Picked Up 6/1/2022 APPLICANT
Plan Check Approved 10/11/2022 SEWADA ZADOORAN MILAGARDI
Issued 10/11/2022 APPLICANT
CofO in Progress 7/31/2024 MATTHEW NELSON
CofO in Progress 8/5/2024 MATTHEW NELSON
CofO in Progress 8/5/2024 MATTHEW NELSON
Permit Finaled 8/7/2024 RUBEN SALAS
CofO Issued 8/7/2024 RUBEN SALAS
Permit Finaled 8/7/2024 RUBEN SALAS

Permit Application Clearance Information

Address approval Cleared 6/23/2022 JOSE DUARTE-DIAZ
Eng Process Fee Ord 176,300 Cleared 6/24/2022 JOSE DUARTE-DIAZ
Sewer availability Cleared 6/24/2022 JOSE DUARTE-DIAZ
Clean Up Green Up Cleared 7/18/2022 MIGUEL GAMBOA
Hydrant and Access approval Cleared 8/20/2022 RUEL COLE
Roof/Waste drainage to street Cleared 10/11/2022 COLIN LOREDO

Contact Information

Contractor Owner-Builder       ,
Engineer Khatchadourian,, Vicken; Lic. No.: S3141 1221 N CEDAR ST      GLENDALE, CA 92107

Inspector Information

MATTHEW NELSON, (818) 374-1170 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Underground Mechanical 1/27/2023 Partial Approval MATTHEW NELSON
Footing/Foundation/Slab 2/1/2023 Approved MATTHEW NELSON
Floor/Roof Diaphrgm/Shear Wall 2/17/2023 Partial Approval MATTHEW NELSON
ELECTRICAL-Rough 5/17/2023 Approved MATTHEW NELSON
Floor/Roof Diaphrgm/Shear Wall 5/17/2023 Approved MATTHEW NELSON
Green Building Rough 5/17/2023 Approved MATTHEW NELSON
PLUMBING-Rough 5/17/2023 Approved MATTHEW NELSON
HVAC-Rough 5/23/2023 Corrections Issued MATTHEW NELSON
Shower Pan 5/23/2023 Approved MATTHEW NELSON
Interior/Exterior Lathing 6/7/2023 Approved MATTHEW NELSON
Insulation 6/15/2023 Approved MATTHEW NELSON
Interior/Exterior Lathing 6/30/2023 Approved MATTHEW NELSON
Gas Test 10/31/2023 Approved DAVID ANDERSON
Sewer 10/31/2023 Approved DAVID ANDERSON
Underground Mechanical 10/31/2023 Approved DAVID ANDERSON
Service/Power Release 11/13/2023 Not Ready for Inspection CARLOS MATAMOROS
Gas Test 2/29/2024 Approved MATTHEW NELSON
BUILDING-Rough-Frame 5/9/2024 Approved MATTHEW NELSON
Drywall Nailing 5/9/2024 Approved MATTHEW NELSON
Final 5/9/2024 Corrections Issued MATTHEW NELSON
Green Building Final 5/9/2024 Corrections Issued MATTHEW NELSON
SGSOV-Seismic Gas S/O Valve 5/9/2024 SGSOV Approved MATTHEW NELSON
Service/Power Release 5/9/2024 Approved MATTHEW NELSON
Smoke Detectors 5/9/2024 Approved MATTHEW NELSON
Verify Sprinkler Sign Off 5/9/2024 Approved MATTHEW NELSON
ELECTRICAL-Final 5/30/2024 Not Ready for Inspection MATTHEW NELSON
Final 5/30/2024 Corrections Issued MATTHEW NELSON
Green Building Final 5/30/2024 Approved MATTHEW NELSON
HVAC-Final 5/30/2024 Approved MATTHEW NELSON
PLUMBING-Final 5/30/2024 Approved MATTHEW NELSON
Final 7/31/2024 OK to Issue CofO MATTHEW NELSON