13141 W CREWE ST 91605
Certificate Information: 13141 W CREWE ST 91605
- Application / Permit
- 22010-20000-01226
- Plan Check / Job No.
- B22VN03670
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- NEW 41' X 31'-5" DETACHED ONE-STORY ACCESSORY DWELLING UNIT WITH ATTACHED 21'-7" X 9'-7" OPEN TRELLIS PATIO COVER AND 5' X 3' COVERED ENTRY PORCH PER LAMC 12.22 A.33 (c) AND (d). WORK PER ENGINEER.
- Permit Issued
- Issued on 6/8/2022
- Issuing Office
- Current Status
- Issued on 6/8/2022
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 3/14/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 3/21/2022 | ROSENDO MEDINA |
| Corrections Issued | 3/22/2022 | ROSENDO MEDINA |
| Applicant returned to address corrections | 5/27/2022 | ROSENDO MEDINA |
| Plan Check Approved | 5/31/2022 | ROSENDO MEDINA |
| Issued | 6/8/2022 | APPLICANT |
| Building Plans Picked Up | 6/9/2022 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 3/24/2022 | JOSE DUARTE-DIAZ |
| Eng Process Fee Ord 176,300 | Cleared | 3/29/2022 | JOSE DUARTE-DIAZ |
| Sewer availability | Cleared | 3/29/2022 | JOSE DUARTE-DIAZ |
| Low Impact Development | Cleared | 5/20/2022 | LONDY ALVARADO |
| Construction near power lines | Cleared | 5/23/2022 | RIDWAN HARDY |
| Roof/Waste drainage to street | Cleared | 5/23/2022 | JOSE DUARTE-DIAZ |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Adzhemyan,, Arsen; Lic. No.: C89103 | 1010 RALEIGH ST APT 107 GLENDALE, CA 91205 |
Inspector Information
| WAYNE REGESTER, (818) 374-1164 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 9/6/2022 | Corrections Issued | RAFAEL CORTES |
| Excavation/Setback/Form/Re-Bar | 9/9/2022 | Corrections Issued | RAFAEL CORTES |
| Excavation/Setback/Form/Re-Bar | 9/13/2022 | Approved | RAFAEL CORTES |
| Footing/Foundation/Slab | 9/13/2022 | Approved | RAFAEL CORTES |
| Floor/Roof Diaphrgm/Shear Wall | 10/4/2022 | Corrections Issued | RAFAEL CORTES |
| PLUMBING-Rough | 10/4/2022 | Corrections Issued | RAFAEL CORTES |
| Floor/Roof Diaphrgm/Shear Wall | 10/6/2022 | Off-Hour Fees Due | |
| Floor/Roof Diaphrgm/Shear Wall | 10/6/2022 | Partial Approval | RAFAEL CORTES |
| PLUMBING-Rough | 10/6/2022 | Off-Hour Fees Due | |
| PLUMBING-Rough | 10/6/2022 | Partial Approval | RAFAEL CORTES |
| Floor/Roof Diaphrgm/Shear Wall | 10/12/2022 | Partial Approval | RAFAEL CORTES |
| PLUMBING-Rough | 10/12/2022 | Partial Approval | RAFAEL CORTES |
| Rough-Elec/Plmb/HVAC | 10/12/2022 | Not Ready for Inspection | RAFAEL CORTES |
| Floor/Roof Diaphrgm/Shear Wall | 11/18/2022 | Corrections Issued | WILLIAM WREN |
| Green Building Rough | 11/18/2022 | Approved | WILLIAM WREN |
| PLUMBING-Rough | 11/18/2022 | Approved | WILLIAM WREN |
| Verify Sprinkler Sign Off | 11/18/2022 | Approved | WILLIAM WREN |
| ELECTRICAL-Rough | 11/29/2022 | Approved | MICHEL ABAJAN |
| Floor/Roof Diaphrgm/Shear Wall | 11/29/2022 | Partial Approval | MICHEL ABAJAN |
| HVAC-Rough | 11/29/2022 | Approved | MICHEL ABAJAN |
| BUILDING-Rough-Frame | 12/8/2022 | Approved | KIRK SANDERS |
| ELECTRICAL-Rough | 12/8/2022 | Approved | KIRK SANDERS |
| Interior/Exterior Lathing | 12/8/2022 | Approved | KIRK SANDERS |
| PLUMBING-Rough | 12/8/2022 | Approved | KIRK SANDERS |
| Insulation | 12/14/2022 | Corrections Issued | KIRK SANDERS |
| Drywall Nailing | 12/21/2022 | Approved | KIRK SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 2/6/2023 | Approved | KIRK SANDERS |
| Shower Pan | 2/6/2023 | Approved | KIRK SANDERS |
| Final | 4/26/2023 | Corrections Issued | KIRK SANDERS |
| Green Building Final | 4/26/2023 | Not Ready for Inspection | KIRK SANDERS |
| SGSOV-Seismic Gas S/O Valve | 4/26/2023 | SGSOV Approved | KIRK SANDERS |
| Service/Power Release | 4/26/2023 | Not Ready for Inspection | KIRK SANDERS |
| Smoke Detectors | 4/26/2023 | Approved | KIRK SANDERS |