11938 W REDBANK ST 91352
Certificate Information: 11938 W REDBANK ST 91352
- Application / Permit
- 22010-20000-00981
- Plan Check / Job No.
- B22VN03096
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- (N) 2-STORY ACCESSORY DWELLING UNIT PER LAMC 12.22A33(c)(d)
- Permit Issued
- Issued on 4/10/2023
- Issuing Office
- Valley
- Current Status
- Issued on 4/10/2023
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 3/1/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 3/24/2022 | TROY DEGUZMAN |
| Corrections Issued | 3/31/2022 | TROY DEGUZMAN |
| Quality Review Completed | 4/7/2022 | OMID HEDAYAT |
| Building Plans Picked Up | 4/11/2022 | APPLICANT |
| Plan Check Approved | 3/10/2023 | NILOOFAR MEHRAIN |
| Issued | 4/10/2023 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 4/18/2022 | CARLOS AGUILERA |
| Eng Process Fee Ord 176,300 | Cleared | 4/18/2022 | CARLOS AGUILERA |
| Sewer availability | Cleared | 4/18/2022 | CARLOS AGUILERA |
| ZI | Cleared | 5/1/2022 | STEVEN WECHSLER |
| Construction near power lines | Cleared | 7/6/2022 | TINA MIRANDA |
| Low Impact Development | Cleared | 11/28/2022 | ROGELIO CORTES |
| Hydrant and Access approval | Cleared | 1/29/2023 | KURT CORRAL |
| Roof/Waste drainage to street | Cleared | 2/8/2023 | CARLOS AGUILERA |
| Green Code | Cleared | 3/10/2023 | TROY DEGUZMAN |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Baraty,, Patrick; Lic. No.: S5900 | 1819 SUNSHINE COURT GLENDALE, CA 91208 |
Inspector Information
| WILLIAM WREN, (818) 374-1170 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 3/29/2024 | Approved | MATTHEW NELSON |
| Pre-Inspection | 3/29/2024 | Approved | MATTHEW NELSON |
| BUILDING-Rough-Frame | 4/9/2024 | Partial Approval | MATTHEW NELSON |
| PLUMBING-Rough | 4/9/2024 | Partial Approval | MATTHEW NELSON |
| BUILDING-Rough-Frame | 4/29/2024 | Not Ready for Inspection | MATTHEW NELSON |
| Green Building Rough | 4/29/2024 | Not Ready for Inspection | MATTHEW NELSON |
| MERV13>=Rough | 4/29/2024 | Not Ready for Inspection | MATTHEW NELSON |
| Verify Sprinkler Sign Off | 4/29/2024 | Not Ready for Inspection | MATTHEW NELSON |
| Wood Frame | 4/29/2024 | Not Ready for Inspection | MATTHEW NELSON |
| ELECTRICAL-Rough | 7/24/2024 | Approved | MATTHEW NELSON |
| HVAC-Rough | 7/24/2024 | Not Ready for Inspection | MATTHEW NELSON |
| PLUMBING-Rough | 7/24/2024 | Approved | MATTHEW NELSON |
| HVAC-Rough | 7/29/2024 | Approved | MATTHEW NELSON |
| ELECTRICAL-Rough | 10/17/2024 | Approved | MATTHEW NELSON |
| HVAC-Rough | 10/17/2024 | Approved | MATTHEW NELSON |
| BUILDING-Rough-Frame | 11/7/2024 | Conditional Approval | MICHEL ABAJAN |
| Floor/Roof Diaphrgm/Shear Wall | 11/7/2024 | Partial Approval | MICHEL ABAJAN |
| Green Building Rough | 11/7/2024 | Approved | MICHEL ABAJAN |
| MERV13>=Rough | 11/7/2024 | Approved | MICHEL ABAJAN |
| Verify Sprinkler Sign Off | 11/7/2024 | Approved | MICHEL ABAJAN |
| BUILDING-Rough-Frame | 11/20/2024 | Approved | MATTHEW NELSON |
| Insulation | 11/20/2024 | Approved | MATTHEW NELSON |
| Drywall Nailing | 12/2/2024 | Approved | MATTHEW NELSON |
| Shower Pan | 12/23/2024 | Approved | MATTHEW NELSON |
| Interior/Exterior Lathing | 4/1/2025 | Not Ready for Inspection | MATTHEW NELSON |
| Interior/Exterior Lathing | 4/7/2025 | Approved | MATTHEW NELSON |
| ELECTRICAL-Final | 7/1/2025 | Approved | MATTHEW NELSON |
| ELECTRICAL-Final | 7/22/2025 | Approved | MATTHEW NELSON |
| Service/Power Release | 7/22/2025 | Not Ready for Inspection | MATTHEW NELSON |