6066 W OLYMPIC BLVD 90036

Certificate Information: 6066 W OLYMPIC BLVD 90036

Application / Permit
22010-10003-06040
Plan Check / Job No.
B25LA52273
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
Supplemental to Steel Stairs #1 & #2 1. Structural steel miscellaneous iron, shall conform to ASTM A-36. Wide Flange members shall conform to ASTM A-992 Fy=50 KSI. Pipe Columns shall conform to astm a-53 Grade "b". Steel tubes shall conform to ASTM A-500 Grade "B" Fy=46 KSI. 2. Bolted Connections shall conform to AISC specifications, using bolts conforming to ASTM A-307 and connecting material conforming to ASTM-A-36. 3. Use E-70 Series Electrodes. 4. Welds shall be uniform in size and appearance and free of pinholes, porosity, and other defects 5. Field welding shall be done under continuous inspection of a registered deputy building inspector. 6. All steel members, connection plates, and bolts to be stainless steel or heavily galvanized.
Permit Issued
Issued on 2/9/2026
Issuing Office
Current Status
Issued on 2/9/2026

Permit Application Status History

Submitted 12/12/2025 APPLICANT
Assigned to Plan Check Engineer 1/8/2026 TSE MING HUANG
Corrections Issued 1/12/2026 TSE MING HUANG
Quality Review Completed 1/14/2026 ARMEN JIVALAGIAN
Plan Check Approved 2/9/2026 TSE MING HUANG
Issued 2/9/2026 APPLICANT

Permit Application Clearance Information

No Data Available.

Contact Information

Contractor Frymer Construction; Lic. No.: 860661-B       ,
Contractor Frymer Development Inc; Lic. No.: 860661-B       ,
Engineer Rubeiz,, Nadim Michel; Lic. No.: NA69454       ,

Inspector Information

IAN BLINN, (213) 482-7361 Office Hours: 7:00-8:00 AM MON-FRI
CHRISTOPHER BLACKWOOD, (213) 482-7361 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

No Data Available.