637 N BAY VIEW AVE 90744
Certificate Information: 637 N BAY VIEW AVE 90744
- Application / Permit
- 22010-10000-06589
- Plan Check / Job No.
- B22LA26482
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- New 1-story ADU per Ordinanace.
- Permit Issued
- Issued on 12/28/2023
- Issuing Office
- South Los Angeles
- Current Status
- CofO Issued on 2/24/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/29/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 1/5/2023 | VICTOR CHEN |
| Corrections Issued | 1/9/2023 | VICTOR CHEN |
| Building Plans Picked Up | 1/20/2023 | APPLICANT |
| Applicant returned to address corrections | 12/21/2023 | RICARDO RAMIREZ |
| Plan Check Approved | 12/28/2023 | LUKE GONZALES |
| Issued | 12/28/2023 | APPLICANT |
| CofO in Progress | 2/20/2025 | EUGENE CASSIDY |
| CofO Issued | 2/24/2025 | ANSON MAGLASANG |
| Permit Finaled | 2/24/2025 | ANSON MAGLASANG |
Permit Application Clearance Information
| Address approval | Cleared | 6/9/2023 | KHAING AYE |
| Permit | Cleared | 6/9/2023 | KHAING AYE |
| Eng Process Fee Ord 176,300 | Cleared | 7/13/2023 | KHAING AYE |
| Sewer availability | Cleared | 7/13/2023 | KHAING AYE |
| Low Impact Development | Cleared | 11/14/2023 | MELINEH AGHAKHABIAN |
| Roof/Waste drainage to street | Cleared | 11/15/2023 | KHAING AYE |
| Construction within easement | Cleared | 12/12/2023 | RIDWAN HARDY |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Garcia,, Francisco Diaz; Lic. No.: C88029 | 19145 MALABAR ST SANTA CLARITA, CA 91351 |
Inspector Information
| EUGENE CASSIDY, (310) 548-2508 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 3/1/2024 | Corrections Issued | EUGENE CASSIDY |
| METHANE-Barrier | 3/1/2024 | Approved | EUGENE CASSIDY |
| METHANE-Subgrade | 3/1/2024 | Approved | EUGENE CASSIDY |
| Footing/Foundation/Slab | 3/6/2024 | Approved | EUGENE CASSIDY |
| Floor/Roof Diaphrgm/Shear Wall | 3/18/2024 | Partial Approval | JAMES CHAVEZ |
| PLUMBING-Rough | 3/18/2024 | Partial Approval | JAMES CHAVEZ |
| Sewer | 3/18/2024 | Partial Approval | JAMES CHAVEZ |
| Insulation | 3/21/2024 | Partial Approval | EUGENE CASSIDY |
| Floor/Roof Diaphrgm/Shear Wall | 3/22/2024 | Partial Approval | JAMES CHAVEZ |
| BUILDING-Rough-Frame | 4/5/2024 | Not Ready for Inspection | BEN MOLSTAD |
| Green Building Rough | 4/5/2024 | Not Ready for Inspection | BEN MOLSTAD |
| METHANE-Rough | 4/5/2024 | Corrections Issued | BEN MOLSTAD |
| Verify Sprinkler Sign Off | 4/5/2024 | Not Ready for Inspection | BEN MOLSTAD |
| BUILDING-Rough-Frame | 4/22/2024 | Partial Approval | EUGENE CASSIDY |
| ELECTRICAL-Rough | 4/22/2024 | Not Ready for Inspection | EUGENE CASSIDY |
| Floor/Roof Diaphrgm/Shear Wall | 4/22/2024 | Partial Approval | EUGENE CASSIDY |
| Green Building Rough | 4/22/2024 | Not Ready for Inspection | EUGENE CASSIDY |
| METHANE-Rough | 4/22/2024 | Approved | EUGENE CASSIDY |
| PLUMBING-Rough | 4/22/2024 | Approved | EUGENE CASSIDY |
| Verify Sprinkler Sign Off | 4/22/2024 | Approved | EUGENE CASSIDY |
| ELECTRICAL-Rough | 5/10/2024 | Approved | EUGENE CASSIDY |
| Sewer | 5/10/2024 | Approved | EUGENE CASSIDY |
| HVAC-Rough | 5/16/2024 | Approved | EUGENE CASSIDY |
| Insulation | 5/16/2024 | Corrections Issued | EUGENE CASSIDY |
| Interior/Exterior Lathing | 5/16/2024 | Partial Approval | EUGENE CASSIDY |
| Wood Frame | 5/16/2024 | Approved | EUGENE CASSIDY |
| Insulation | 5/21/2024 | Approved | EUGENE CASSIDY |
| Drywall Nailing | 5/23/2024 | Approved | EUGENE CASSIDY |
| Interior/Exterior Lathing | 5/31/2024 | Approved | EUGENE CASSIDY |
| Service/Power Release | 9/13/2024 | Corrections Issued | JOSEPH MCGARRY |
| Service/Power Release | 9/27/2024 | Partial Approval | EUGENE CASSIDY |
| SGSOV-Seismic Gas S/O Valve | 10/25/2024 | SGSOV Not Ready | EUGENE CASSIDY |
| BUILDING-Rough-Frame | 2/11/2025 | Approved | EUGENE CASSIDY |
| Final | 2/11/2025 | Corrections Issued | EUGENE CASSIDY |
| Green Building Final | 2/11/2025 | Approved | EUGENE CASSIDY |
| Green Building Rough | 2/11/2025 | Approved | EUGENE CASSIDY |
| SGSOV-Seismic Gas S/O Valve | 2/11/2025 | SGSOV Not Ready | EUGENE CASSIDY |
| Service/Power Release | 2/11/2025 | Not Ready for Inspection | EUGENE CASSIDY |
| Smoke Detectors | 2/11/2025 | Approved | EUGENE CASSIDY |
| Final | 2/19/2025 | OK to Issue CofO | EUGENE CASSIDY |
| SGSOV-Seismic Gas S/O Valve | 2/19/2025 | SGSOV Approved | EUGENE CASSIDY |
| Service/Power Release | 2/19/2025 | Not Required | EUGENE CASSIDY |