1750 S NAVY WAY 90731
Certificate Information: 1750 S NAVY WAY 90731
- Application / Permit
- 22010-10000-06475
- Plan Check / Job No.
- B22LA26293
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- Commercial
- Primary Use
- (23) Miscellaneous Bldg/Structure
- Work Description
- ePlan Proposed 1-story training building. 1 OF 3
- Permit Issued
- Issued on 10/3/2023
- Issuing Office
- Current Status
- CofO Issued on 11/8/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
Submitted | 12/28/2022 | APPLICANT |
Assigned to Plan Check Engineer | 1/12/2023 | MICHAEL LOPEZ |
Corrections Issued | 1/24/2023 | MICHAEL LOPEZ |
Quality Review Completed | 2/6/2023 | TEODORO DIAZ RODRIGUEZ |
Applicant returned to address corrections | 3/6/2023 | MICHAEL LOPEZ |
Applicant returned to address corrections | 3/14/2023 | MICHAEL LOPEZ |
Plan Check Approved | 10/2/2023 | MICHAEL LOPEZ |
Issued | 10/3/2023 | APPLICANT |
TCO Issued (Expire Date: 02-23-2025) | 8/27/2024 | JOEY BUCHANAN |
CofO in Progress | 10/31/2024 | JOEY BUCHANAN |
Permit Finaled | 11/8/2024 | HENRY BAGHDASSARIAN |
CofO Issued | 11/8/2024 | HENRY BAGHDASSARIAN |
Permit Finaled | 11/8/2024 | HENRY BAGHDASSARIAN |
Permit Application Clearance Information
Highway dedication | Cleared | 1/27/2023 | ERIK BEASLEY |
Port of LA Approval | Cleared | 2/3/2023 | CHRISTINA SAR |
"Q" conditions | Cleared | 2/7/2023 | ASHLEY RODARTE |
City Hist. Cultural Monument | Cleared | 2/7/2023 | MAX LODER |
Coastal Zone | Cleared | 2/7/2023 | ASHLEY RODARTE |
Historic monument | Cleared | 2/7/2023 | MAX LODER |
Permit | Cleared | 2/8/2023 | ERIK BEASLEY |
Sewer availability | Cleared | 2/13/2023 | ANA SORIANO |
City owned building/parcel | Cleared | 2/23/2023 | MICHAEL LOPEZ |
Prkng lot landscape/Water mgmt | Cleared | 2/28/2023 | ASHLEY RODARTE |
Hydrant and Access approval | Cleared | 3/21/2023 | JOHN CONNEALLY |
Eng Process Fee Ord 176,300 | Cleared | 3/22/2023 | ANA SORIANO |
Low Impact Development | Cleared | 8/9/2023 | ORVAL HERNANDEZ-MARCI |
Stormwater Pollution Mitigatn | Cleared | 8/9/2023 | ORVAL HERNANDEZ-MARCI |
Roof/Waste drainage to street | Cleared | 8/10/2023 | ANA SORIANO |
Drainage to Storm Drain | Cleared | 8/15/2023 | ANA SORIANO |
Green Code | Cleared | 8/16/2023 | Hernan Arreola |
Flood clearance | Cleared | 9/13/2023 | MIGUEL RODRIGUEZ |
DAS Clearance | Cleared | 9/15/2023 | Hernan Arreola |
Building over 36-ft | Cleared | 10/2/2023 | CALOSHA APPROVED |
Contact Information
Contractor | Mason Builders; Lic. No.: 1042113-B | 149 PARKSHORE DR FOLSOM, CA 95630 |
Engineer | Anklesaria,, Bejun; Lic. No.: C64613 | 2918 CREEK TERRACE DR MISSOURI CITY, TX 77459 |
Engineer | Hatcher,, Mark Cameron; Lic. No.: NA47370 | , |
Engineer | Hodali,, Ramzi; Lic. No.: S3552 | 3830 DIXIE CANYON AVE SHERMAN OAKS, CA 91423 |
Inspector Information
JOEY BUCHANAN, (310) 732-4553 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
No Data Available. |
Inspection Request History
Structural Steel Frame | 10/5/2023 | Not Ready for Inspection | JOEY BUCHANAN |
Deputy Reinf. Concrete | 10/12/2023 | Approved | JOEY BUCHANAN |
Insulation | 10/13/2023 | Partial Approval | JOEY BUCHANAN |
Insulation | 11/2/2023 | Approved | AMANUEL BERHE |
Insulation | 11/8/2023 | Partial Approval | JOEY BUCHANAN |
Insulation | 11/21/2023 | Partial Approval | JOEY BUCHANAN |
Insulation | 11/29/2023 | No Access for Inspection | JOEY BUCHANAN |
Floor/Roof Diaphrgm/Shear Wall | 12/1/2023 | Approved | JOEY BUCHANAN |
Insulation | 12/12/2023 | Approved | JOEY BUCHANAN |
Insulation | 1/16/2024 | Partial Approval | JOEY BUCHANAN |
Insulation | 2/9/2024 | Partial Approval | JOEY BUCHANAN |
Insulation | 3/13/2024 | Approved | JOEY BUCHANAN |
Pre-Inspection | 4/16/2024 | Approved | JOEY BUCHANAN |
Pre-Inspection | 5/15/2024 | Approved | JOEY BUCHANAN |
Pre-Inspection | 6/21/2024 | Approved | JOEY BUCHANAN |
Final | 8/8/2024 | Not Ready for Inspection | JOEY BUCHANAN |
Final | 10/31/2024 | OK to Issue CofO | JOEY BUCHANAN |
Footing/Foundation/Slab | 10/31/2024 | Approved | JOEY BUCHANAN |
Green Building Final | 10/31/2024 | Approved | JOEY BUCHANAN |
Green Building Rough | 10/31/2024 | Approved | JOEY BUCHANAN |
METHANE-Barrier | 10/31/2024 | Approved | JOEY BUCHANAN |
METHANE-Final | 10/31/2024 | Approved | JOEY BUCHANAN |
METHANE-Rough | 10/31/2024 | Approved | JOEY BUCHANAN |
METHANE-Subgrade | 10/31/2024 | Approved | JOEY BUCHANAN |
Reinforced Masonry Frame | 10/31/2024 | Approved | JOEY BUCHANAN |
SGSOV-Seismic Gas S/O Valve | 10/31/2024 | SGSOV Approved | JOEY BUCHANAN |
Smoke Detectors | 10/31/2024 | Approved | JOEY BUCHANAN |
Verify Sprinkler Sign Off | 10/31/2024 | Approved | JOEY BUCHANAN |