3500 W GREENSWARD ROAD 90039

Certificate Information: 3500 W GREENSWARD ROAD 90039

Application / Permit
22010-10000-06461
Plan Check / Job No.
B22LA26241
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
ePlan 2 story New 1200 SF detached ADU PER LAMC 12.22 A33 (c)(d)
Permit Issued
Issued on 5/27/2023
Issuing Office
Current Status
CofO Issued on 5/4/2026
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 12/27/2022 APPLICANT
Assigned to Plan Check Engineer 1/27/2023 KHUONG TRUONG
Corrections Issued 1/29/2023 KHUONG TRUONG
Applicant returned to address corrections 4/13/2023 KHUONG TRUONG
Plan Check Approved 5/15/2023 KHUONG TRUONG
Issued 5/27/2023 APPLICANT
CofO in Progress 3/31/2026 NICHOLAS LOPEZ
No Progress 4/2/2026 DEROLD HAUFF
CofO in Progress 4/2/2026 DEROLD HAUFF
Permit Finaled 5/4/2026 DEROLD HAUFF
CofO Issued 5/4/2026 DEROLD HAUFF
Permit Finaled 5/4/2026 DEROLD HAUFF

Permit Application Clearance Information

Address approval Cleared 3/3/2023 TREVOR QUAN
ZI Cleared 3/3/2023 MAXFIELD VERMY
ZI Cleared 3/3/2023 MAXFIELD VERMY
Eng Process Fee Ord 176,300 Cleared 3/6/2023 TREVOR QUAN
Sewer availability Cleared 3/6/2023 TREVOR QUAN
Stormwater Pollution Mitigatn Cleared 4/25/2023 LUIS LUVANO
Roof/Waste drainage to street Cleared 4/26/2023 CINDY QI

Contact Information

Architect Allsbrook,, Jeffrey W; Lic. No.: C27181 3519 DAHLIA AVENUE      LOS ANGELES, CA 90026
Contractor Owner-Builder       ,
Engineer Polon,, Gordon Leonard; Lic. No.: C28564 709 19TH STREET      SANTA MONICA, CA 90402

Inspector Information

NICHOLAS LOPEZ, (213) 202-3224 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 7/5/2023 Partial Inspection HAMIK HARTOUNIAN
Underground Mechanical 7/13/2023 Partial Approval HAMIK HARTOUNIAN
Excavation/Setback/Form/Re-Bar 7/25/2023 Approved HAMIK HARTOUNIAN
Footing/Foundation/Slab 7/25/2023 Approved HAMIK HARTOUNIAN
Footing/Foundation/Slab 8/4/2023 Conditional Approval HAMIK HARTOUNIAN
Sewer 8/22/2023 Approved HAMIK HARTOUNIAN
Floor/Roof Diaphrgm/Shear Wall 10/20/2023 Partial Approval HAMIK HARTOUNIAN
Green Building Rough 10/20/2023 Not Ready for Inspection HAMIK HARTOUNIAN
MERV13>=Rough 10/20/2023 Not Ready for Inspection HAMIK HARTOUNIAN
Verify Sprinkler Sign Off 10/20/2023 Not Ready for Inspection HAMIK HARTOUNIAN
Excavation/Setback/Form/Re-Bar 1/11/2024 Partial Approval HAMIK HARTOUNIAN
ELECTRICAL-Rough 2/28/2024 Corrections Issued HAMIK HARTOUNIAN
Floor/Roof Diaphrgm/Shear Wall 2/28/2024 Corrections Issued HAMIK HARTOUNIAN
PLUMBING-Rough 2/28/2024 Approved HAMIK HARTOUNIAN
Floor/Roof Diaphrgm/Shear Wall 3/6/2024 Partial Approval HAMIK HARTOUNIAN
HVAC-Rough 3/6/2024 Corrections Issued HAMIK HARTOUNIAN
Floor/Roof Diaphrgm/Shear Wall 4/10/2024 Approved HAMIK HARTOUNIAN
HVAC-Rough 4/10/2024 Approved HAMIK HARTOUNIAN
BUILDING-Rough-Frame 4/19/2024 Not Ready for Inspection HAMIK HARTOUNIAN
Green Building Rough 4/19/2024 Approved HAMIK HARTOUNIAN
MERV13>=Rough 4/19/2024 Approved HAMIK HARTOUNIAN
Verify Sprinkler Sign Off 4/19/2024 Corrections Issued HAMIK HARTOUNIAN
BUILDING-Rough-Frame 5/6/2024 Corrections Issued THOMAS LOGRASSO
Verify Sprinkler Sign Off 5/6/2024 Approved THOMAS LOGRASSO
Interior/Exterior Lathing 5/15/2024 Not Ready for Inspection THOMAS LOGRASSO
BUILDING-Rough-Frame 6/6/2024 Conditional Approval THOMAS LOGRASSO
Interior/Exterior Lathing 6/6/2024 Partial Approval THOMAS LOGRASSO
Interior/Exterior Lathing 7/16/2024 Partial Approval JOSH MEISTER
Shower Pan 9/16/2024 Approved THOMAS LOGRASSO
BUILDING-Rough-Frame 10/7/2024 Corrections Issued THOMAS LOGRASSO
Insulation 10/7/2024 Corrections Issued THOMAS LOGRASSO
Interior/Exterior Lathing 10/7/2024 Partial Approval THOMAS LOGRASSO
BUILDING-Rough-Frame 10/28/2024 Approved THOMAS LOGRASSO
Insulation 10/28/2024 Approved THOMAS LOGRASSO
Drywall Nailing 11/8/2024 Approved ANTHONY RAMOS
ELECTRICAL-Rough 2/25/2025 Approved WILLIAM SIERRA
PLUMBING-Rough 2/25/2025 Approved WILLIAM SIERRA
PLUMBING-Final 5/16/2025 Not Ready for Inspection NICHOLAS LOPEZ
Pre-Inspection 5/16/2025 Partial Inspection NICHOLAS LOPEZ
Service/Power Release 5/16/2025 Not Ready for Inspection NICHOLAS LOPEZ
Smoke Detectors 5/16/2025 Not Ready for Inspection NICHOLAS LOPEZ
Pre-Inspection 9/12/2025 Partial Inspection NICHOLAS LOPEZ
ELECTRICAL-Final 10/1/2025 Approved NICHOLAS LOPEZ
PLUMBING-Final 10/1/2025 Approved NICHOLAS LOPEZ
Service/Power Release 10/1/2025 Approved NICHOLAS LOPEZ
Special/Order Compliance 10/1/2025 Corrections Issued NICHOLAS LOPEZ
Final 2/19/2026 Corrections Issued NICHOLAS LOPEZ
Footing/Foundation/Slab 2/19/2026 Approved NICHOLAS LOPEZ
Green Building Final 2/19/2026 Approved NICHOLAS LOPEZ
HVAC-Final 2/19/2026 Approved NICHOLAS LOPEZ
MERV13>=Final 2/19/2026 Approved NICHOLAS LOPEZ
SGSOV-Seismic Gas S/O Valve 2/19/2026 SGSOV No Gas NICHOLAS LOPEZ
Smoke Detectors 2/19/2026 Approved NICHOLAS LOPEZ
Final 3/27/2026 OK to Issue CofO NICHOLAS LOPEZ