1564 S SPAULDING AVE 90019

Certificate Information: 1564 S SPAULDING AVE 90019

Application / Permit
22010-10000-04745
Plan Check / Job No.
B22LA19197
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
ePlan. PROPOSED 1200 SQ.FT TWO-STORY DETACHED ADU PER ORDINANCE
Permit Issued
Issued on 4/13/2023
Issuing Office
Current Status
CofO Issued on 6/24/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 9/23/2022 APPLICANT
Assigned to Plan Check Engineer 10/13/2022 JAD BASMA
Corrections Issued 10/21/2022 JAD BASMA
Quality Review Completed 10/27/2022 GARO TELMI
Applicant returned to address corrections 11/7/2022 JAD BASMA
Applicant returned to address corrections 3/24/2023 JAD BASMA
Plan Check Approved 4/4/2023 JAD BASMA
Issued 4/13/2023 APPLICANT
CofO in Progress 6/17/2024 ENRIQUE MIRELES
Permit Finaled 6/24/2024 DEROLD HAUFF
CofO Issued 6/24/2024 DEROLD HAUFF
Permit Finaled 6/24/2024 DEROLD HAUFF

Permit Application Clearance Information

Address approval Cleared 11/4/2022 AMAAN MALIK
Eng Process Fee Ord 176,300 Cleared 11/8/2022 AMAAN MALIK
Sewer availability Cleared 11/8/2022 AMAAN MALIK
Construction near power lines Cleared 1/6/2023 RIDWAN HARDY
Low Impact Development Cleared 1/30/2023 ROGELIO CORTES
Roof/Waste drainage to street Cleared 2/8/2023 AMAAN MALIK

Contact Information

Architect Beauter,, William L; Lic. No.: NA29188       ,
Contractor Owner-Builder       ,
Engineer , ; Lic. No.: S5593       ,

Inspector Information

DAVID WILLIAMS, (213) 202-3126 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 7/24/2023 Partial Inspection FREDDIE RIVERA
METHANE-Barrier 7/24/2023 Partial Inspection FREDDIE RIVERA
METHANE-Subgrade 7/24/2023 Partial Inspection FREDDIE RIVERA
Excavation/Setback/Form/Re-Bar 7/28/2023 Approved MICHAEL LEWIS
Footing/Foundation/Slab 7/28/2023 Off-Hour Fees Due
Footing/Foundation/Slab 7/28/2023 Partial Approval MICHAEL LEWIS
METHANE-Barrier 7/28/2023 Not Ready for Inspection MICHAEL LEWIS
METHANE-Barrier 7/28/2023 Off-Hour Fees Due
METHANE-Subgrade 7/28/2023 Not Ready for Inspection MICHAEL LEWIS
METHANE-Subgrade 7/28/2023 Off-Hour Fees Due
METHANE-Subgrade 8/11/2023 Approved LILIANA PORTILLO
PLUMBING-Rough 8/11/2023 Partial Approval LILIANA PORTILLO
Deputy Methane Barrier 8/16/2023 Approved RONNIE MINDANAO
Deputy Methane Barrier 8/16/2023 Conditional Approval JOSE AVILA
Deputy Methane Barrier 8/17/2023 Conditional Approval JOSE AVILA
Deputy Methane Barrier 8/24/2023 Conditional Approval JOSE AVILA
Footing/Foundation/Slab 8/25/2023 Partial Approval JOSE AVILA
METHANE-Barrier 8/25/2023 Approved JOSE AVILA
METHANE-Rough 8/25/2023 Approved JOSE AVILA
Floor/Roof Diaphrgm/Shear Wall 9/19/2023 Corrections Issued JOSE AVILA
Underground Mechanical 10/16/2023 Corrections Issued JOSE AVILA
Floor/Roof Diaphrgm/Shear Wall 10/26/2023 Corrections Issued RONNIE MINDANAO
Deputy Methane Barrier 11/20/2023 Conditional Approval ALIZAH MAYAGOITIA
Verify Sprinkler Sign Off 11/20/2023 Corrections Issued JOSE AVILA
Floor/Roof Diaphrgm/Shear Wall 11/27/2023 Partial Approval ALIZAH MAYAGOITIA
Wood Frame 11/27/2023 Not Ready for Inspection ALIZAH MAYAGOITIA
BUILDING-Rough-Frame 12/6/2023 Partial Approval STUART CHAPMAN
ELECTRICAL-Rough 12/6/2023 Approved STUART CHAPMAN
HVAC-Rough 12/6/2023 Approved STUART CHAPMAN
Interior/Exterior Lathing 12/6/2023 Approved STUART CHAPMAN
METHANE-Rough 12/6/2023 Approved STUART CHAPMAN
PLUMBING-Rough 12/6/2023 Approved STUART CHAPMAN
Insulation 12/13/2023 Not Ready for Inspection RONNIE MINDANAO
Insulation 12/18/2023 Corrections Issued ALIZAH MAYAGOITIA
Drywall Nailing 1/2/2024 Approved JOSH MEISTER
Insulation 1/2/2024 Approved JOSH MEISTER
Shower Pan 1/2/2024 Approved JOSH MEISTER
Interior/Exterior Lathing 1/18/2024 Approved BRENDAN MORELLI
ELECTRICAL-Final 3/5/2024 Not Ready for Inspection STUART CHAPMAN
HVAC-Final 3/5/2024 Not Ready for Inspection STUART CHAPMAN
PLUMBING-Final 3/5/2024 Not Ready for Inspection STUART CHAPMAN
Service/Power Release 3/5/2024 Not Ready for Inspection STUART CHAPMAN
BUILDING-Rough-Frame 3/27/2024 Not Ready for Inspection STUART CHAPMAN
ELECTRICAL-Final 3/27/2024 Not Ready for Inspection STUART CHAPMAN
Final 3/27/2024 Corrections Issued STUART CHAPMAN
Footing/Foundation/Slab 3/27/2024 Approved STUART CHAPMAN
Green Building Final 3/27/2024 Approved STUART CHAPMAN
Green Building Rough 3/27/2024 Approved STUART CHAPMAN
HVAC-Final 3/27/2024 Not Ready for Inspection STUART CHAPMAN
PLUMBING-Final 3/27/2024 Not Ready for Inspection STUART CHAPMAN
SGSOV-Seismic Gas S/O Valve 3/27/2024 SGSOV Not Ready STUART CHAPMAN
Service/Power Release 3/27/2024 Not Ready for Inspection STUART CHAPMAN
Smoke Detectors 3/27/2024 Not Ready for Inspection STUART CHAPMAN
Verify Sprinkler Sign Off 3/27/2024 Approved STUART CHAPMAN
ELECTRICAL-Final 4/12/2024 Corrections Issued RICHARD DOCKUS
ELECTRICAL-Final 4/16/2024 Approved RICHARD DOCKUS
BUILDING-Rough-Frame 4/18/2024 Approved RICHARD DOCKUS
HVAC-Final 4/18/2024 Corrections Issued RICHARD DOCKUS
PLUMBING-Final 4/18/2024 Approved RICHARD DOCKUS
SGSOV-Seismic Gas S/O Valve 4/18/2024 SGSOV Approved RICHARD DOCKUS
Smoke Detectors 4/18/2024 Approved RICHARD DOCKUS
ELECTRICAL-Final 4/19/2024 Approved RICHARD DOCKUS
Service/Power Release 4/19/2024 Approved RICHARD DOCKUS
HVAC-Final 4/26/2024 Approved RICHARD DOCKUS
Final 5/2/2024 Corrections Issued RICHARD DOCKUS
Final 5/14/2024 Partial Approval ARTHUR NEGRETE
Final 5/30/2024 Not Ready for Inspection ARTHUR NEGRETE
Special/Order Compliance 5/30/2024 Partial Approval JOAQUIN GREENOUGH
Final 6/3/2024 Corrections Issued ENRIQUE MIRELES
Final 6/14/2024 OK to Issue CofO ENRIQUE MIRELES