645 1/2 W 85TH ST 90044
Certificate Information: 645 1/2 W 85TH ST 90044
- Application / Permit
- 22010-10000-04090
- Plan Check / Job No.
- B22LA16315
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT (E) 18' X 20' DETACHED GARAGE TO ACCESSORY DWELLING UNIT (360 SQ FT) PER GCS 65852.2 (e) (1) (A).
- Permit Issued
- Issued on 11/3/2022
- Issuing Office
- Current Status
- CofO Issued on 11/3/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/16/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 8/19/2022 | ALEC MOUSAKHANIAN |
| Corrections Issued | 8/20/2022 | ALEC MOUSAKHANIAN |
| Plan Check Approved | 10/5/2022 | JEROME MAGAT PALMA |
| Plan Check Approved | 11/1/2022 | ALEC MOUSAKHANIAN |
| No Progress | 11/1/2022 | ALEC MOUSAKHANIAN |
| Plan Check Approved | 11/2/2022 | ALEC MOUSAKHANIAN |
| Issued | 11/3/2022 | APPLICANT |
| CofO in Progress | 10/31/2023 | MICHAEL LEWIS |
| CofO Issued | 11/3/2023 | DEROLD HAUFF |
| Permit Finaled | 11/3/2023 | DEROLD HAUFF |
Permit Application Clearance Information
| Address approval | Cleared | 9/6/2022 | JEANETTE VONG |
| Roof/Waste drainage to street | Cleared | 9/6/2022 | JEANETTE VONG |
| Sewer availability | Cleared | 9/6/2022 | JEANETTE VONG |
| Eng Process Fee Ord 176,300 | Cleared | 9/8/2022 | JEANETTE VONG |
| Construction near power lines | Cleared | 9/27/2022 | TINA MIRANDA |
| Hold | Cleared | 2/1/2023 | MARIA VENDIVIL |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Espino,, Manuel A; Lic. No.: C55526 | 12109 WOODRUFF AVE DOWNEY, CA 90241 |
Inspector Information
| JOHN QUINTANILLA, (213) 792-6055 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 12/15/2022 | Corrections Issued | LILIANA PORTILLO |
| PLUMBING-Rough | 12/15/2022 | Corrections Issued | LILIANA PORTILLO |
| PLUMBING-Rough | 12/23/2022 | Partial Approval | LILIANA PORTILLO |
| Footing/Foundation/Slab | 2/15/2023 | Partial Approval | LILIANA PORTILLO |
| Underground Mechanical | 2/23/2023 | Partial Approval | LILIANA PORTILLO |
| ELECTRICAL-Rough | 3/17/2023 | Not Ready for Inspection | LILIANA PORTILLO |
| Floor/Roof Diaphrgm/Shear Wall | 3/17/2023 | Corrections Issued | LILIANA PORTILLO |
| Gas Test | 3/17/2023 | Not Ready for Inspection | LILIANA PORTILLO |
| Green Building Rough | 3/17/2023 | Not Ready for Inspection | LILIANA PORTILLO |
| HVAC-Rough | 3/17/2023 | Not Ready for Inspection | LILIANA PORTILLO |
| PLUMBING-Rough | 3/17/2023 | Not Ready for Inspection | LILIANA PORTILLO |
| Floor/Roof Diaphrgm/Shear Wall | 3/30/2023 | No Access for Inspection | LILIANA PORTILLO |
| Footing/Foundation/Slab | 3/30/2023 | No Access for Inspection | LILIANA PORTILLO |
| Floor/Roof Diaphrgm/Shear Wall | 4/4/2023 | Partial Approval | STUART CHAPMAN |
| Footing/Foundation/Slab | 4/4/2023 | Approved | STUART CHAPMAN |
| ELECTRICAL-Rough | 4/20/2023 | Corrections Issued | LILIANA PORTILLO |
| Gas Test | 4/20/2023 | Approved | LILIANA PORTILLO |
| HVAC-Rough | 4/20/2023 | Corrections Issued | LILIANA PORTILLO |
| PLUMBING-Rough | 4/20/2023 | Corrections Issued | LILIANA PORTILLO |
| BUILDING-Rough-Frame | 4/25/2023 | Corrections Issued | LILIANA PORTILLO |
| ELECTRICAL-Rough | 4/25/2023 | Approved | LILIANA PORTILLO |
| HVAC-Rough | 4/25/2023 | Approved | LILIANA PORTILLO |
| PLUMBING-Rough | 4/25/2023 | Approved | LILIANA PORTILLO |
| BUILDING-Rough-Frame | 5/2/2023 | Approved | MICHAEL LEWIS |
| Insulation | 5/2/2023 | Approved | MICHAEL LEWIS |
| Interior/Exterior Lathing | 5/2/2023 | Approved | MICHAEL LEWIS |
| Drywall Nailing | 5/9/2023 | Approved | MICHAEL LEWIS |
| Special/Order Compliance | 7/26/2023 | Approved | MICHAEL LEWIS |
| Service/Power Release | 8/25/2023 | Partial Inspection | MICHAEL LEWIS |
| ELECTRICAL-Final | 10/3/2023 | Approved | MICHAEL LEWIS |
| HVAC-Final | 10/3/2023 | Corrections Issued | MICHAEL LEWIS |
| PLUMBING-Final | 10/3/2023 | Approved | MICHAEL LEWIS |
| BUILDING-Rough-Frame | 10/16/2023 | Approved | JUSTIN HAWLEY |
| Final | 10/16/2023 | Corrections Issued | JUSTIN HAWLEY |
| Green Building Final | 10/16/2023 | Approved | JUSTIN HAWLEY |
| Green Building Rough | 10/16/2023 | Approved | JUSTIN HAWLEY |
| SGSOV-Seismic Gas S/O Valve | 10/16/2023 | SGSOV Approved | JUSTIN HAWLEY |
| Smoke Detectors | 10/16/2023 | Approved | JUSTIN HAWLEY |
| Final | 10/30/2023 | OK to Issue CofO | MICHAEL LEWIS |