6216 N ELLENVIEW AVE 91307

Certificate Information: 6216 N ELLENVIEW AVE 91307

Application / Permit
21047-20000-01286
Plan Check / Job No.
B21VN07002
Group
Building
Type
Swimming-Pool/Spa
Sub-Type
1 or 2 Family Dwelling
Primary Use
(20) Pool/Spa - Private
Work Description
NEW 15'-0 x 28'-0" POOL WITH 7'-0" x 7'-0" SPA PER CITY STANDARD PLAN #270
Permit Issued
Issued on 6/24/2021
Issuing Office
Current Status
CofO Issued on 3/9/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 6/4/2021 APPLICANT
Assigned to Plan Check Engineer 6/7/2021 ALFRED RAMIREZ
Corrections Issued 6/7/2021 ALFRED RAMIREZ
Issued 6/24/2021 APPLICANT
Building Plans Picked Up 6/25/2021 APPLICANT
CofO in Progress 4/8/2022 TROY SANDERS
Permit Finaled 3/9/2023 DANIEL ORRANTE
CofO Issued 3/9/2023 DANIEL ORRANTE
Permit Finaled 3/9/2023 DANIEL ORRANTE

Permit Application Clearance Information

Grading Pre-Inspection Cleared 6/7/2021 ALFRED RAMIREZ

Contact Information

Contractor Owner-Builder       ,
Engineer Cristescu,, Barbu D; Lic. No.: C72038 14401 SYLVAN STREET 209      VAN NUYS, CA 91401

Inspector Information

GEVORK IPCHYAN, (818) 774-4308 Office Hours: 7:00-8:00 AM MON-FRI
TROY SANDERS, (818) 774-4308 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 8/27/2021 Approved TROY SANDERS
Pool Piping 8/27/2021 Approved TROY SANDERS
Pre-Gunite 8/27/2021 Approved TROY SANDERS
Rough-Electrical 8/27/2021 Approved TROY SANDERS
Deputy Shotcrete 9/9/2021 Partial Approval TROY SANDERS
Deck 11/18/2021 Approved TROY SANDERS
Enclosure/Fence 12/17/2021 Partial Approval DAVID SCANTLIN
SGSOV-Seismic Gas S/O Valve 3/24/2022 SGSOV Not Ready TROY SANDERS
Equipment Noise Level 3/29/2022 Approved FELIPE PENICHE
Final 4/8/2022 OK to Issue CofO TROY SANDERS
SGSOV-Seismic Gas S/O Valve 4/8/2022 SGSOV Approved TROY SANDERS