1980 N CUMMINGS DR 90027

Certificate Information: 1980 N CUMMINGS DR 90027

Application / Permit
21047-20000-00685
Plan Check / Job No.
B21VN03666
Group
Building
Type
Swimming-Pool/Spa
Sub-Type
1 or 2 Family Dwelling
Primary Use
(20) Pool/Spa - Private
Work Description
NEW POOL ON CAISSONS PER ENGINEERING.
Permit Issued
Issued on 6/10/2021
Issuing Office
Current Status
CofO Issued on 3/23/2022
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 3/26/2021 APPLICANT
Assigned to Plan Check Engineer 3/31/2021 COLIN LOREDO
Corrections Issued 4/8/2021 COLIN LOREDO
Quality Review Completed 4/9/2021 OMID HEDAYAT
Plan Check Approved 6/8/2021 COLIN LOREDO
Issued 6/10/2021 APPLICANT
Building Plans Picked Up 6/18/2021 APPLICANT
CofO in Progress 3/2/2022 BRIAN SULLIVAN
Permit Finaled 3/23/2022 DEROLD HAUFF
CofO Issued 3/23/2022 DEROLD HAUFF
Permit Finaled 3/23/2022 DEROLD HAUFF

Permit Application Clearance Information

Grading Pre-Inspection Cleared 4/8/2021 COLIN LOREDO

Contact Information

Contractor Luxe H2o Incorporated; Lic. No.: 295434-C53 2500 EAST FOOTHILL BLVD #415      PASADENA, CA 91107
Engineer Thompson,, Matthew Gregory; Lic. No.: C86051 1201 N TUSTIN AVE      ANAHEIM, CA 92807

Inspector Information

CRAIG VAUGHAN, (213) 202-3250 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 7/21/2021 Corrections Issued BRIAN SULLIVAN
Excavation/Setback/Form/Re-Bar 7/23/2021 Conditional Approval RAUL BARAJAS
Deputy Other (see comments) 7/29/2021 Conditional Approval RAUL BARAJAS
Pre-Gunite 8/23/2021 Corrections Issued SCOTT FINNILA
Pre-Gunite 8/27/2021 Not Ready for Inspection BRIAN SULLIVAN
Deputy Shotcrete 9/13/2021 Conditional Approval ROBERT CORNELL
Pre-Gunite 9/13/2021 Approved BRIAN SULLIVAN
Enclosure/Fence 12/1/2021 Corrections Issued JOSEPH MCGARRY
Enclosure/Fence 12/23/2021 Not Ready for Inspection RAUL BARAJAS
Enclosure/Fence 1/4/2022 Approved RAUL BARAJAS
Excavation/Setback/Form/Re-Bar 3/1/2022 Approved BRIAN SULLIVAN
Final 3/1/2022 OK to Issue CofO BRIAN SULLIVAN
SGSOV-Seismic Gas S/O Valve 3/1/2022 SGSOV Approved BRIAN SULLIVAN