5529 N BUFFALO AVE 91401
Certificate Information: 5529 N BUFFALO AVE 91401
- Application / Permit
- 21047-20000-00491
- Plan Check / Job No.
- B21VN02601
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- NEW 27' X 17' POOL AND 10' X 8' SPA PER STD PLAN # 268 AND DETAIL # 271-60.
- Permit Issued
- Issued on 4/26/2021
- Issuing Office
- Valley
- Current Status
- Issued on 4/26/2021
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 3/4/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 3/9/2021 | PINANK PATEL |
| Corrections Issued | 3/9/2021 | PINANK PATEL |
| Applicant returned to address corrections | 4/8/2021 | MARVEL DELACRUZ |
| Plan Check Approved | 4/26/2021 | PINANK PATEL |
| Issued | 4/26/2021 | APPLICANT |
| Building Plans Picked Up | 4/27/2021 | APPLICANT |
Permit Application Clearance Information
| Construction near power lines | Cleared | 4/26/2021 | JOHN BACON |
| Construction within easement | Cleared | 4/26/2021 | OSCAR CASTRO |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Biedenbach,, Christopher James; Lic. No.: C74003 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
Inspector Information
| JOSE AVILA, (818) 374-1173 | Office Hours: 7:00-8:00 AM MON-FRI |
| VINCENT HANLEY, (818) 374-1173 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 5/5/2021 | Approved | DAVID SCANTLIN |
| Pre-Gunite | 5/5/2021 | Approved | DAVID SCANTLIN |
| Deputy Shotcrete | 5/11/2021 | Conditional Approval | MICHAEL TEMPLE |
| Enclosure/Fence | 7/28/2021 | Corrections Issued | CHARLES POWELL |
| Final | 7/28/2021 | Not Ready for Inspection | CHARLES POWELL |
| Pre-Inspection | 7/28/2021 | Partial Inspection | ADAM ESCOTO |
| Pre-Inspection | 7/28/2021 | Partial Inspection | AMY COLIN |
| Final | 8/9/2021 | Corrections Issued | JENNIFER RABUCHIN |
| SGSOV-Seismic Gas S/O Valve | 8/9/2021 | SGSOV Approved | JENNIFER RABUCHIN |
| Final | 8/19/2021 | Corrections Issued | RICHARD DOCKUS |
| Equipment Noise Level | 8/24/2021 | Approved | FELIPE PENICHE |
| Final | 8/26/2021 | Not Ready for Inspection | RICHARD DOCKUS |