2821 S VIRGINIA ROAD 90016

Certificate Information: 2821 S VIRGINIA ROAD 90016

Application / Permit
21030-10000-02348
Plan Check / Job No.
B21LA06729
Group
Building
Type
Grading
Sub-Type
1 or 2 Family Dwelling
Primary Use
(60) Grading - Non-Hillside
Work Description
PROPOSED REMOVE AN RECOMPACTION FOR NEW SFD AND DUPLEX BUILDINGS; MAX 717 CY, MAX 5' DEEP
Permit Issued
Issued on 5/19/2021
Issuing Office
Current Status
Permit Finaled on 8/9/2022

Permit Application Status History

Submitted 4/12/2021 APPLICANT
Assigned to Plan Check Engineer 4/12/2021 SINA KHOSRAVI
Corrections Issued 4/13/2021 SINA KHOSRAVI
Plan Check Approved 5/5/2021 ADAM HEGAZI
Issued 5/19/2021 APPLICANT
Building Plans Picked Up 7/15/2021 APPLICANT
Permit Finaled 8/8/2022 ALEXANDER HELFER

Permit Application Clearance Information

No Data Available.

Contact Information

Contractor Owner-Builder       ,
Engineer Moughraby,, Ousama; Lic. No.: C91595 9744 MAPLE ST      BELLFLOWER, CA 90706

Inspector Information

AL GAMBLE, (213) 482-0403 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Bottom/Toe 5/20/2021 Corrections Issued VASIL MIHALEV
Final 5/20/2021 Not Ready for Inspection VASIL MIHALEV
Rough 5/20/2021 Not Ready for Inspection VASIL MIHALEV
Approved Compaction Report 6/3/2021 Approved ROBERT HUGHES
Bottom/Toe 6/3/2021 Not Ready for Inspection VASIL MIHALEV
Final 6/3/2021 Not Ready for Inspection VASIL MIHALEV
Rough 6/3/2021 Not Ready for Inspection VASIL MIHALEV
Bottom/Toe 8/8/2022 Approved ALEXANDER HELFER
Final 8/8/2022 Permit Finaled ALEXANDER HELFER
Rough 8/8/2022 Approved ALEXANDER HELFER