4000 N BALLINA DR 91436
Certificate Information: 4000 N BALLINA DR 91436
- Application / Permit
- 21020-20000-02296
- Plan Check / Job No.
- B21VN13762
- Group
- Building
- Type
- Nonbldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (23) Retaining Wall
- Work Description
- 2 NEW RETAINING WALLS ON PILES [RET. WALL 1 L: 34'-6" MAX HT: 10'] [RET. WALL 2 L: 175' MAX HT: 10']
- Permit Issued
- Issued on 3/17/2023
- Issuing Office
- West Los Angeles
- Current Status
- Permit Finaled on 1/27/2026
Permit Application Status History
| Submitted | 10/8/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 10/21/2021 | SEAN SHAHMIRI |
| Corrections Issued | 10/24/2021 | SEAN SHAHMIRI |
| Quality Review Completed | 10/26/2021 | OMID HEDAYAT |
| Building Plans Picked Up | 11/1/2021 | APPLICANT |
| Applicant returned to address corrections | 4/12/2022 | SEAN SHAHMIRI |
| Applicant returned to address corrections | 5/6/2022 | SEAN SHAHMIRI |
| Plan Check Approved | 8/9/2022 | SEAN SHAHMIRI |
| Issued | 3/17/2023 | APPLICANT |
| Permit Finaled | 1/27/2026 | ROBERT PINA |
Permit Application Clearance Information
| Construction near power lines | Cleared | 11/22/2021 | WALTER RAMIREZ |
| Landscape for retaining wall | Cleared | 2/18/2022 | MIGUEL GAMBOA |
Contact Information
| Contractor | Sperling Group Inc; Lic. No.: 1061452-B | 11769 CHENAULT STREET LOS ANGELES, CA 90049 |
| Engineer | Yuzon,, Benigno Sari; Lic. No.: S3454 | 2511 PEACHWOOD PLACE WESTLAKE VILLAGE, CA 91361 |
| Geologist | Feffer,, Joshua Rafael; Lic. No.: EG2138 | 12253 GORHAM AVE LOS ANGELES, CA 90049 |
Inspector Information
| MANUEL TEJADA, (818) 374-4339 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 5/22/2023 | Approved | ROBERT PINA |
| Piling/Pier/Caisson | 6/7/2023 | Partial Approval | ROBERT PINA |
| Deputy Reinf. Concrete | 6/8/2023 | Approved | ROBERT PINA |
| Excavation/Setback/Form/Re-Bar | 9/6/2023 | Partial Approval | ROBERT PINA |
| Excavation/Setback/Form/Re-Bar | 9/22/2023 | Approved | ROBERT PINA |
| Footing/Foundation/Slab | 9/22/2023 | Partial Approval | ROBERT PINA |
| Excavation/Setback/Form/Re-Bar | 10/23/2023 | Partial Approval | ROBERT PINA |
| Excavation/Setback/Form/Re-Bar | 3/19/2024 | Approved | ROBERT PINA |
| Excavation/Setback/Form/Re-Bar | 4/3/2024 | Partial Approval | ROBERT PINA |
| Excavation/Setback/Form/Re-Bar | 4/25/2024 | Approved | ROBERT PINA |
| Excavation/Setback/Form/Re-Bar | 12/17/2025 | Not Ready for Inspection | MANUEL TEJADA |
| Final | 1/27/2026 | Permit Finaled | ROBERT PINA |