121 S AVALON BLVD 90744
Certificate Information: 121 S AVALON BLVD 90744
- Application / Permit
- 21020-10000-01833
- Plan Check / Job No.
- B21LA15443
- Group
- Building
- Type
- Nonbldg-New
- Sub-Type
- Commercial
- Primary Use
- (23) Retaining Wall
- Work Description
- Concrete reinforced retaining wall supported on precast prestressed concrete piles for a future park and Avalon pedestrian bridge project. Design heights for retaining wall are 14', 17', and 20' total length of 584'.
- Permit Issued
- Issued on 1/27/2026
- Issuing Office
- San Pedro
- Current Status
- Issued on 1/27/2026
Permit Application Status History
| Submitted | 3/1/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 3/24/2022 | KESETE HAREGOT |
| Corrections Issued | 4/1/2022 | KESETE HAREGOT |
| Quality Review Completed | 4/5/2022 | FARUK SEZER |
| Building Plans Picked Up | 4/7/2022 | APPLICANT |
| Applicant returned to address corrections | 3/27/2024 | KESETE HAREGOT |
| Plan Check Approved | 12/17/2025 | KESETE HAREGOT |
| Issued | 1/27/2026 | APPLICANT |
Permit Application Clearance Information
| Landscape for retaining wall | Cleared | 9/16/2022 | MAXFIELD VERMY |
| Drainage to Storm Drain | Cleared | 12/21/2022 | ANA SORIANO |
| Eng Process Fee Ord 176,300 | Cleared | 12/21/2022 | ANA SORIANO |
| Low Impact Development | Cleared | 1/29/2025 | AMMAR ELTAWIL |
| City owned building/parcel | Cleared | 6/20/2025 | MASON NG |
| Roof/Waste drainage to street | Cleared | 6/27/2025 | VISHAL MANDALIA |
| Historic monument | Cleared | 7/7/2025 | MELISSA JONES |
| "D" conditions | Cleared | 7/17/2025 | RUBEN VASQUEZ |
| Coastal Zone | Cleared | 7/17/2025 | RUBEN VASQUEZ |
| Miscellaneous | Cleared | 7/17/2025 | RUBEN VASQUEZ |
Contact Information
| Contractor | Skanska Usa Civil West California District Inc; Lic. No.: 140069-A | 1995 AGUA MANSA RD RIVERSIDE, CA 92509 |
| Engineer | Fitzwilliam,, Daniel Joseph; Lic. No.: C58937 | 14867 CHESFIELD CT SAN DIEGO, CA 92127 |
Inspector Information
| MICHAEL PETRUSKO, (310) 732-4552 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| No Data Available. |