14001 W BURTON ST 91402
Certificate Information: 14001 W BURTON ST 91402
- Application / Permit
- 21016-30000-18722
- Plan Check / Job No.
- X21WL04304
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- Concrete block freestanding masonry fence walls constructed per Information Bulletin P/BC 2020-096 located in residential zones, maximum 6 feet height above grade, and not located in the required front yard or within 5 feet of the side street lot line of a reverse corner lot (subject to additional limitations of LAMC Section 12.22C20(f) and Information bulletin P/ZC 2002-002).
- Permit Issued
- Issued on 7/20/2021
- Issuing Office
- Current Status
- Permit Finaled on 9/1/2021
Permit Application Status History
| Issued | 7/20/2021 | APPLICANT |
| Permit Finaled | 9/1/2021 | GREGG CUMMINGS |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| OGANES TARAKHCHYAN, (818) 374-1162 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 7/23/2021 | Approved | GREGG CUMMINGS |
| Footing/Foundation/Slab | 7/23/2021 | Approved | GREGG CUMMINGS |
| Masonry Wall/Backfill | 7/27/2021 | Approved | GREGG CUMMINGS |
| Masonry Wall/Backfill | 7/30/2021 | Partial Approval | GREGG CUMMINGS |
| Final | 8/13/2021 | Corrections Issued | GREGG CUMMINGS |
| SGSOV-Seismic Gas S/O Valve | 8/13/2021 | SGSOV Not Ready | GREGG CUMMINGS |
| Smoke Detectors | 8/13/2021 | No Access for Inspection | GREGG CUMMINGS |
| Final | 9/1/2021 | Permit Finaled | GREGG CUMMINGS |
| SGSOV-Seismic Gas S/O Valve | 9/1/2021 | SGSOV Approved | GREGG CUMMINGS |
| Smoke Detectors | 9/1/2021 | Approved | GREGG CUMMINGS |