1221 3/4 S BURNSIDE AVE 90019
Certificate Information: 1221 3/4 S BURNSIDE AVE 90019
- Application / Permit
- 21016-20000-51726
- Plan Check / Job No.
- B21VN15348
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT THE (E) GARAGE INTO AN IRREGULAR SINGLE-STORY 22.33' x 26' (N - 464 SF) ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) AND (d), STORAGE AND UTILITY ROOM.
- Permit Issued
- Issued on 8/17/2022
- Issuing Office
- Metro
- Current Status
- CofO Issued on 2/7/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/10/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 11/23/2021 | LUIS RINCON |
| Corrections Issued | 11/25/2021 | LUIS RINCON |
| Applicant returned to address corrections | 4/11/2022 | LUIS RINCON |
| Applicant returned to address corrections | 5/18/2022 | LUIS RINCON |
| Plan Check Approved | 6/8/2022 | LUIS RINCON |
| Building Plans Picked Up | 6/9/2022 | APPLICANT |
| Issued | 8/17/2022 | APPLICANT |
| CofO in Progress | 1/25/2023 | JOSE AVILA |
| Permit Finaled | 2/7/2023 | DEROLD HAUFF |
| CofO Issued | 2/7/2023 | DEROLD HAUFF |
| Permit Finaled | 2/7/2023 | DEROLD HAUFF |
Permit Application Clearance Information
| Construction near power lines | Cleared | 3/11/2022 | RIDWAN HARDY |
| Address approval | Cleared | 4/22/2022 | JEANIE LAM |
| Sewer availability | Cleared | 4/25/2022 | JEANIE LAM |
| Miscellaneous | Cleared | 4/29/2022 | PABLO ESTRADA |
| Eng Process Fee Ord 176,300 | Cleared | 5/2/2022 | JEANIE LAM |
| Tenant Habitability Plan | Cleared | 5/4/2022 | ISMAEL HERNANDEZ |
Contact Information
| Contractor | Electra - Comm Inc; Lic. No.: 671634-B | 148 W OLIVE AVE MONROVIA, CA 91016 |
| Engineer | Attaalla,, Sayed Ahmed; Lic. No.: S5339 | 11254 HANNUM AVE CULVER CITY, CA 90230 |
Inspector Information
| DAVID WILLIAMS, (213) 202-3126 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 8/26/2022 | Conditional Approval | JOSE AVILA |
| Excavation/Setback/Form/Re-Bar | 9/2/2022 | Partial Approval | JOSE AVILA |
| PLUMBING-Rough | 9/2/2022 | Corrections Issued | JOSE AVILA |
| ELECTRICAL-Rough | 9/8/2022 | Corrections Issued | JOSE AVILA |
| PLUMBING-Rough | 9/8/2022 | Approved | JOSE AVILA |
| BUILDING-Rough-Frame | 9/14/2022 | Corrections Issued | JOSE AVILA |
| ELECTRICAL-Rough | 9/14/2022 | Approved | JOSE AVILA |
| HVAC-Rough | 9/14/2022 | Corrections Issued | JOSE AVILA |
| Floor/Roof Diaphrgm/Shear Wall | 9/16/2022 | No Access for Inspection | JOSE AVILA |
| BUILDING-Rough-Frame | 9/22/2022 | Partial Approval | JOSE AVILA |
| HVAC-Rough | 9/22/2022 | Approved | JOSE AVILA |
| Insulation | 9/23/2022 | Approved | JOSE AVILA |
| Drywall Nailing | 10/3/2022 | Partial Approval | JOSE AVILA |
| Green Building Rough | 10/3/2022 | Approved | JOSE AVILA |
| Interior/Exterior Lathing | 10/6/2022 | Approved | JOSE AVILA |
| Shower Pan | 10/6/2022 | Approved | JOSE AVILA |
| BUILDING-Rough-Frame | 11/2/2022 | Approved | JOSE AVILA |
| Drywall Nailing | 11/2/2022 | Approved | JOSE AVILA |
| Final | 11/2/2022 | Corrections Issued | JOSE AVILA |
| Green Building Final | 11/2/2022 | Corrections Issued | JOSE AVILA |
| METHANE-Final | 11/2/2022 | Approved | JOSE AVILA |
| METHANE-Rough | 11/2/2022 | Approved | JOSE AVILA |
| SGSOV-Seismic Gas S/O Valve | 11/2/2022 | SGSOV Not Ready | JOSE AVILA |
| Smoke Detectors | 11/2/2022 | Approved | JOSE AVILA |
| ELECTRICAL-Final | 11/22/2022 | Corrections Issued | MICHAEL LEWIS |
| HVAC-Final | 11/22/2022 | Corrections Issued | MICHAEL LEWIS |
| PLUMBING-Final | 11/22/2022 | Corrections Issued | MICHAEL LEWIS |
| ELECTRICAL-Final | 11/30/2022 | Corrections Issued | JOSE AVILA |
| HVAC-Final | 11/30/2022 | Corrections Issued | JOSE AVILA |
| PLUMBING-Final | 11/30/2022 | Approved | JOSE AVILA |
| ELECTRICAL-Final | 12/5/2022 | Approved | JOSE AVILA |
| HVAC-Final | 12/5/2022 | Approved | JOSE AVILA |
| PLUMBING-Final | 12/5/2022 | Approved | JOSE AVILA |
| Green Building Final | 1/11/2023 | Approved | JOSE AVILA |
| SGSOV-Seismic Gas S/O Valve | 1/11/2023 | SGSOV Approved | JOSE AVILA |
| Final | 1/24/2023 | OK to Issue CofO | JOSE AVILA |
| Service/Power Release | 1/24/2023 | Approved | JOSE AVILA |