18561-18563 W STARE ST 91324

Certificate Information: 18561-18563 W STARE ST 91324

Application / Permit
21016-20000-24029
Plan Check / Job No.
B21VN12026
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
ePlan ADU conversion. Convert (E) 469 S.F attached garage to JADU PER GCS 65852.2(e)(1)(A) AND 65852.2
Permit Issued
Issued on 12/30/2021
Issuing Office
Current Status
CofO Issued on 9/29/2022
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 9/20/2021 APPLICANT
Assigned to Plan Check Engineer 9/21/2021 CARLOS MONTES
Corrections Issued 9/23/2021 CRYSTEL MAALOUF
Applicant returned to address corrections 11/1/2021 CRYSTEL MAALOUF
Applicant returned to address corrections 11/30/2021 CARLOS MONTES
Applicant returned to address corrections 12/22/2021 CARLOS MONTES
Plan Check Approved 12/23/2021 CARLOS MONTES
Issued 12/30/2021 APPLICANT
CofO in Progress 9/29/2022 JEFFREY BULL
Permit Finaled 9/29/2022 JOHN JANSON
CofO Issued 9/29/2022 JOHN JANSON
Permit Finaled 9/29/2022 JOHN JANSON

Permit Application Clearance Information

Address approval Cleared 11/18/2021 CARLOS AGUILERA
Eng Process Fee Ord 176,300 Cleared 11/18/2021 CARLOS AGUILERA
Sewer availability Cleared 11/18/2021 CARLOS AGUILERA

Contact Information

Contractor Choe Craig; Lic. No.: 867838-B 3183 WILSHIRE BLVD   196 - E33    LOS ANGELES, CA 90010

Inspector Information

JACK KARGODORIAN, (818) 774-4319 Office Hours: 7:00-8:00 AM MON-FRI
KRISTEN CAUSEY, (818) 774-4319 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 1/18/2022 Partial Approval DAVID SCANTLIN
Footing/Foundation/Slab 1/18/2022 Approved DAVID SCANTLIN
PLUMBING-Rough 2/1/2022 Partial Approval JEFFREY PARD
Floor/Roof Diaphrgm/Shear Wall 2/11/2022 Approved JEFFREY PARD
ELECTRICAL-Rough 2/22/2022 Approved JEFFREY PARD
PLUMBING-Rough 2/22/2022 Approved JEFFREY PARD
BUILDING-Rough-Frame 3/2/2022 Approved JEFFREY PARD
Green Building Rough 3/2/2022 Not Ready for Inspection JEFFREY PARD
Deputy Wood Construction 3/11/2022 Conditional Approval JUSTIN HAWLEY
Insulation 3/15/2022 Conditional Approval JUSTIN HAWLEY
Interior/Exterior Lathing 3/15/2022 Not Ready for Inspection JUSTIN HAWLEY
Interior/Exterior Lathing 3/21/2022 Approved JUSTIN HAWLEY
Drywall Nailing 4/7/2022 Approved JUSTIN HAWLEY
Green Building Rough 4/7/2022 Approved JUSTIN HAWLEY
Insulation 4/7/2022 Approved JUSTIN HAWLEY
Interior/Exterior Lathing 4/7/2022 Approved JUSTIN HAWLEY
ELECTRICAL-Final 8/26/2022 Approved JEFFREY PARD
Green Building Final 8/26/2022 Corrections Issued JEFFREY PARD
PLUMBING-Final 8/26/2022 Approved JEFFREY PARD
Final 9/2/2022 Corrections Issued JEFFREY PARD
Green Building Final 9/2/2022 Approved JEFFREY PARD
SGSOV-Seismic Gas S/O Valve 9/2/2022 SGSOV Approved JEFFREY PARD
Service/Power Release 9/2/2022 Not Ready for Inspection JEFFREY PARD
Smoke Detectors 9/2/2022 Approved JEFFREY PARD
Final 9/15/2022 Corrections Issued VINCENT HANLEY
Final 9/28/2022 OK to Issue CofO JEFFREY BULL