14036 N SADDLE RIDGE ROAD 91342
Certificate Information: 14036 N SADDLE RIDGE ROAD 91342
- Application / Permit
- 21016-20000-18768
- Plan Check / Job No.
- B21VN09448
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- INTERIOR REMODEL TO (E) SFD TO REMOVE KITCHEN LOAD-BEARING WALL. ALL WORK DONE PER ENGINEERING.
- Permit Issued
- Issued on 9/12/2021
- Issuing Office
- Current Status
- Permit Finaled on 11/26/2021
Permit Application Status History
| Submitted | 7/20/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 7/26/2021 | GURUNATH NESARAJAH |
| Corrections Issued | 7/26/2021 | GURUNATH NESARAJAH |
| Plan Check Approved | 8/30/2021 | GURUNATH NESARAJAH |
| Building Plans Picked Up | 9/1/2021 | APPLICANT |
| Issued | 9/12/2021 | APPLICANT |
| Permit Finaled | 11/24/2021 | MICHAEL TEMPLE |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 8/19/2021 | PATRICK MISCHLICH |
Contact Information
| Contractor | T & N Remodeling Inc; Lic. No.: 1063782-B | 7716 WISH AVE VAN NUYS, CA 91406 |
| Engineer | Standley,, Craig Erick; Lic. No.: C87675 | 5330 ZELZAH AVE UNIT 7 ENCINO, CA 91316 |
Inspector Information
| KEVIN BERBERYAN, (818) 374-9931 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| BUILDING-Rough-Frame | 9/21/2021 | Not Ready for Inspection | JOHN HAYES |
| Special/Order Compliance | 9/23/2021 | Corrections Issued | JOHN HAYES |
| ELECTRICAL-Rough | 9/27/2021 | Partial Approval | JOHN HAYES |
| Excavation/Setback/Form/Re-Bar | 9/27/2021 | Approved | JOHN HAYES |
| PLUMBING-Rough | 9/27/2021 | Partial Approval | JOHN HAYES |
| BUILDING-Rough-Frame | 9/30/2021 | Not Ready for Inspection | JOHN HAYES |
| ELECTRICAL-Rough | 9/30/2021 | Not Ready for Inspection | JOHN HAYES |
| Footing/Foundation/Slab | 9/30/2021 | Not Ready for Inspection | JOHN HAYES |
| Insulation | 9/30/2021 | Not Ready for Inspection | JOHN HAYES |
| Rough-Elec/Plmb/HVAC | 10/4/2021 | Partial Approval | JOHN HAYES |
| BUILDING-Rough-Frame | 10/7/2021 | Approved | JOHN HAYES |
| ELECTRICAL-Rough | 10/7/2021 | Approved | JOHN HAYES |
| HVAC-Rough | 10/7/2021 | Approved | JOHN HAYES |
| Insulation | 10/7/2021 | Approved | JOHN HAYES |
| PLUMBING-Rough | 10/7/2021 | Approved | JOHN HAYES |
| Rough-Elec/Plmb/HVAC | 10/7/2021 | Approved | JOHN HAYES |
| Drywall Nailing | 10/12/2021 | Approved | JESUS RODRIGUEZ |
| Interior/Exterior Lathing | 10/25/2021 | Approved | JOHN HAYES |
| Final | 11/24/2021 | Permit Finaled | MICHAEL TEMPLE |
| Smoke Detectors | 11/24/2021 | Approved | MICHAEL TEMPLE |