4533 N TOBIAS AVE 91403
Certificate Information: 4533 N TOBIAS AVE 91403
- Application / Permit
- 21016-20000-17122
- Plan Check / Job No.
- B21VN08541
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- SAND BLAST THE (E) STUCCO, APPLY SIDING, RELOCATE THREE ELECTRICAL LIGHTS, AND RELOCATE PLUMBING MAIN RISER TO (E) ONE-STORY SFD.
- Permit Issued
- Issued on 7/5/2021
- Issuing Office
- Current Status
- Permit Finaled on 10/13/2021
Permit Application Status History
| Submitted | 7/1/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 7/2/2021 | TROY DEGUZMAN |
| Plan Check Approved | 7/5/2021 | TROY DEGUZMAN |
| Issued | 7/5/2021 | APPLICANT |
| Permit Finaled | 10/13/2021 | MISAEL ESPARZA |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Srs Builders Inc; Lic. No.: 972622-B | 23777 MULHOLLAND HWY SPC 129 CALABASAS, CA 91302 |
Inspector Information
| MISAEL ESPARZA, (818) 374-1169 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Insulation | 8/6/2021 | Approved | AMY COLIN |
| Interior/Exterior Lathing | 8/11/2021 | Not Ready for Inspection | RYAN SALAZAR |
| Interior/Exterior Lathing | 8/12/2021 | Approved | AMY COLIN |
| Interior/Exterior Lathing | 8/17/2021 | Corrections Issued | ALIZAH MAYAGOITIA |
| Interior/Exterior Lathing | 8/19/2021 | Approved | ALIZAH MAYAGOITIA |
| Final | 10/8/2021 | Corrections Issued | MISAEL ESPARZA |
| SGSOV-Seismic Gas S/O Valve | 10/8/2021 | SGSOV Not Ready | MISAEL ESPARZA |
| Smoke Detectors | 10/8/2021 | Approved | MISAEL ESPARZA |
| Final | 10/13/2021 | Permit Finaled | MISAEL ESPARZA |
| SGSOV-Seismic Gas S/O Valve | 10/13/2021 | SGSOV Approved | MISAEL ESPARZA |