727 W 82ND ST 90044

Certificate Information: 727 W 82ND ST 90044

Application / Permit
21016-10000-58670
Plan Check / Job No.
B21LA23671
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
Eplan: Soft-Story seismic retrofit per LABC Chapter 93: SOFT STORY SEISMIC REINFORCEMENT AT BUILDING PARKING GARAGE USING (2) SPECIAL CANTILEVERED COLUMNS W/ GRADE BEAMS.
Permit Issued
Issued on 7/27/2022
Issuing Office
Current Status
CofC Issued on 12/28/2022

Permit Application Status History

Submitted 12/20/2021 APPLICANT
Assigned to Plan Check Engineer 1/20/2022 JESSE VIDUYA
Corrections Issued 1/24/2022 JESSE VIDUYA
Quality Review Completed 2/3/2022 HANS SANTIAGO
Applicant returned to address corrections 2/22/2022 JESSE VIDUYA
Applicant returned to address corrections 3/22/2022 JESSE VIDUYA
Applicant returned to address corrections 4/27/2022 JESSE VIDUYA
Applicant returned to address corrections 5/13/2022 JESSE VIDUYA
Plan Check Approved 5/23/2022 JESSE VIDUYA
Issued 7/27/2022 APPLICANT
OK for CofC 12/19/2022 DARRYL ARNOLD
CofC Issued 12/28/2022 WINSTON DUNNING

Permit Application Clearance Information

Tenant Habitability Plan Cleared 7/25/2022 RICARDO BOHORQUEZ

Contact Information

Contractor Retrofit 1; Lic. No.: 1003868-B 19326 VENTURA BLVD STE 200      TARZANA, CA 91356
Engineer Ni,, Zhang Yuan; Lic. No.: C68149 8232 GARVEY AVE 203      ROSEMEAD, CA 91770

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 8/10/2022 Conditional Approval DARRYL ARNOLD
Deputy Steel/Welding 8/18/2022 Conditional Approval DARRYL ARNOLD
Deputy Steel/Welding 8/19/2022 Conditional Approval DARRYL ARNOLD
Deputy Drilled-In Anchors 8/30/2022 Conditional Approval DARRYL ARNOLD
Footing/Foundation/Slab 8/31/2022 Corrections Issued DARRYL ARNOLD
Structural Steel Frame 8/31/2022 Conditional Approval DARRYL ARNOLD
Wood Frame 8/31/2022 Conditional Approval DARRYL ARNOLD
Interior/Exterior Lathing 9/7/2022 Conditional Approval DARRYL ARNOLD
Final 10/12/2022 Corrections Issued DARRYL ARNOLD
SGSOV-Seismic Gas S/O Valve 10/12/2022 SGSOV Approved DARRYL ARNOLD
Smoke Detectors 10/12/2022 Corrections Issued DARRYL ARNOLD
Smoke Detectors 10/18/2022 Conditional Approval DARRYL ARNOLD
Final 10/19/2022 Corrections Issued DARRYL ARNOLD
Special/Order Compliance 11/28/2022 Approved DARRYL ARNOLD
Final 12/2/2022 Not Ready for Inspection DARRYL ARNOLD
Smoke Detectors 12/2/2022 Not Ready for Inspection DARRYL ARNOLD
Special/Order Compliance 12/16/2022 Approved DARRYL ARNOLD
Final 12/19/2022 OK for CofC DARRYL ARNOLD
Smoke Detectors 12/19/2022 Approved DARRYL ARNOLD