4884 E AXTELL ST 90032
Certificate Information: 4884 E AXTELL ST 90032
- Application / Permit
- 21016-10000-58190
- Plan Check / Job No.
- B21LA23394
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- ePLAN: Soft-Story seismic retrofit per LABC Chapter 93: Reinforcing soft-story with two steel cantilevered columns and wood shear wall.
- Permit Issued
- Issued on 3/20/2024
- Issuing Office
- Current Status
- CofC Issued on 10/3/2024
Permit Application Status History
| Submitted | 12/17/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 1/12/2022 | VARAND SARKISIAN |
| Corrections Issued | 1/18/2022 | VARAND SARKISIAN |
| Quality Review Completed | 2/1/2022 | HANS SANTIAGO |
| Plan Check Approved | 9/27/2022 | VARAND SARKISIAN |
| Issued | 3/20/2024 | APPLICANT |
| OK for CofC | 8/30/2024 | DARRYL ARNOLD |
| CofC Issued | 10/3/2024 | WINSTON DUNNING |
Permit Application Clearance Information
| Tenant Habitability Plan | Cleared | 3/19/2024 | RICARDO BOHORQUEZ |
Contact Information
| Contractor | Abs Fidelity Builder Inc; Lic. No.: 1062123-B | 4456 ALTA CANYADA ROAD LA CANADA FLINTRIDGE, CA 91011 |
| Engineer | Hwang,, Junho; Lic. No.: NA5592 | , |
Inspector Information
| DARRYL ARNOLD, (213) 482-0341 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 7/10/2024 | Conditional Approval | DARRYL ARNOLD |
| Footing/Foundation/Slab | 7/16/2024 | Approved | JEROME BLACKWOOD |
| Reinforced Concrete Frame | 7/16/2024 | Partial Approval | JEROME BLACKWOOD |
| Deputy Steel/Welding | 7/26/2024 | Conditional Approval | DARRYL ARNOLD |
| Deputy Wood Construction | 7/30/2024 | Conditional Approval | DARRYL ARNOLD |
| Structural Steel Frame | 7/30/2024 | Approved | DARRYL ARNOLD |
| Wood Frame | 7/30/2024 | Approved | DARRYL ARNOLD |
| Deputy Wood Construction | 8/6/2024 | Conditional Approval | RONALD JIMENEZ |
| Floor/Roof Diaphrgm/Shear Wall | 8/12/2024 | Not Ready for Inspection | DARRYL ARNOLD |
| Interior/Exterior Lathing | 8/21/2024 | Approved | DARRYL ARNOLD |
| Final | 8/30/2024 | OK for CofC | DARRYL ARNOLD |
| SGSOV-Seismic Gas S/O Valve | 8/30/2024 | SGSOV Approved | DARRYL ARNOLD |
| Smoke Detectors | 8/30/2024 | Approved | DARRYL ARNOLD |