3307 S MENTONE AVE 90034
Certificate Information: 3307 S MENTONE AVE 90034
- Application / Permit
- 21016-10000-56392
- Plan Check / Job No.
- B21LA22587
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- SOFT STORY RETROFIT AS PER LABC CH. 93. USING TWO BAY MOMENT FRAME AND SHEAR WALL
- Permit Issued
- Issued on 6/13/2023
- Issuing Office
- Metro
- Current Status
- CofC Issued on 1/24/2025
Permit Application Status History
| Submitted | 12/6/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 1/6/2022 | VARAND SARKISIAN |
| Corrections Issued | 1/10/2022 | VARAND SARKISIAN |
| Quality Review Completed | 1/12/2022 | HANS SANTIAGO |
| Building Plans Picked Up | 2/28/2022 | APPLICANT |
| Plan Check Approved | 3/16/2023 | VARAND SARKISIAN |
| Issued | 6/13/2023 | APPLICANT |
| OK for CofC | 1/22/2025 | GRANT WOODS |
| CofC Issued | 1/24/2025 | DAVID TSAU |
Permit Application Clearance Information
| Specific Plan | Cleared | 3/14/2023 | RUBEN VASQUEZ |
| Tenant Habitability Plan | Cleared | 5/17/2023 | RICARDO BOHORQUEZ |
Contact Information
| Contractor | Blue Coast Inc; Lic. No.: 614146-B | PO BOX 5562 SANTA MONICA, CA 904095562 |
| Engineer | Behshid,, Farshid; Lic. No.: S4585 | 10866 WIMER COUNTRY ROAD SUNLAND, CA 91040 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Steel/Welding | 9/5/2024 | Conditional Approval | CHRISTOPHER WILSON |
| Deputy Wood Construction | 9/10/2024 | Conditional Approval | CHRISTOPHER WILSON |
| Excavation/Setback/Form/Re-Bar | 9/11/2024 | Approved | GRANT WOODS |
| Floor/Roof Diaphrgm/Shear Wall | 9/11/2024 | Approved | GRANT WOODS |
| Footing/Foundation/Slab | 9/11/2024 | Approved | GRANT WOODS |
| SGSOV-Seismic Gas S/O Valve | 9/11/2024 | SGSOV Approved | GRANT WOODS |
| Structural Steel Frame | 9/11/2024 | Approved | GRANT WOODS |
| Wall Anchors | 9/11/2024 | Approved | GRANT WOODS |
| Wood Frame | 9/11/2024 | Approved | GRANT WOODS |
| Interior/Exterior Lathing | 9/25/2024 | Approved | GRANT WOODS |
| Final | 11/22/2024 | Conditional Approval | GRANT WOODS |
| Smoke Detectors | 11/22/2024 | Approved | GRANT WOODS |
| Final | 1/22/2025 | OK for CofC | GRANT WOODS |