1520 W HILL DR 90041

Certificate Information: 1520 W HILL DR 90041

Application / Permit
21016-10000-20167
Plan Check / Job No.
B21LA14505
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
INTERIOR REMODEL OF KITCHEN, BATHROOMS, LAUNDRY & HALLWAY. ENLARGE BATHROOM ON SECOND FLOOR BY CONVERTING PART OF ATTIC AREA.
Permit Issued
Issued on 9/19/2021
Issuing Office
Current Status
CofO Issued on 4/19/2022
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 8/3/2021 APPLICANT
Assigned to Plan Check Engineer 8/9/2021 RICARDO RAMIREZ
Corrections Issued 8/10/2021 RICARDO RAMIREZ
Plan Check Approved 8/25/2021 RICARDO RAMIREZ
Issued 9/19/2021 APPLICANT
Building Plans Picked Up 9/23/2021 APPLICANT
CofO in Progress 4/15/2022 CRAIG VAUGHAN
CofO in Progress 4/15/2022 CRAIG VAUGHAN
CofO Issued 4/19/2022 DEROLD HAUFF
Permit Finaled 4/19/2022 DEROLD HAUFF

Permit Application Clearance Information

No Data Available.

Contact Information

Contractor Eagle Rock Restoration; Lic. No.: 1025285-B 5464 WAMEDA AVE      LOS ANGELES, CA 90041
Engineer Tuchscher,, James Todd; Lic. No.: C77649 5503 E 2ND ST      LONG BEACH, CA 90803

Inspector Information

RONNIE MEDINA, (213) 469-5852 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

ELECTRICAL-Rough 12/6/2021 Approved CRAIG VAUGHAN
HVAC-Rough 12/6/2021 Corrections Issued CRAIG VAUGHAN
PLUMBING-Rough 12/6/2021 Partial Approval CRAIG VAUGHAN
Wood Frame 12/6/2021 Approved CRAIG VAUGHAN
ELECTRICAL-Rough 12/10/2021 Approved CRAIG VAUGHAN
HVAC-Rough 12/10/2021 Approved CRAIG VAUGHAN
PLUMBING-Rough 12/10/2021 Approved CRAIG VAUGHAN
Wood Frame 12/10/2021 Approved CRAIG VAUGHAN
Drywall Nailing 1/20/2022 Approved CHARLES BOGHOSKHAN
Interior/Exterior Lathing 1/20/2022 Approved CHARLES BOGHOSKHAN
Shower Pan 1/20/2022 Approved CHARLES BOGHOSKHAN
BUILDING-Rough-Frame 4/14/2022 Approved CRAIG VAUGHAN
ELECTRICAL-Final 4/14/2022 Approved CRAIG VAUGHAN
Final 4/14/2022 OK to Issue CofO CRAIG VAUGHAN
Footing/Foundation/Slab 4/14/2022 Approved CRAIG VAUGHAN
Green Building Final 4/14/2022 Approved CRAIG VAUGHAN
Green Building Rough 4/14/2022 Approved CRAIG VAUGHAN
HVAC-Final 4/14/2022 Approved CRAIG VAUGHAN
PLUMBING-Final 4/14/2022 Approved CRAIG VAUGHAN
SGSOV-Seismic Gas S/O Valve 4/14/2022 SGSOV Approved CRAIG VAUGHAN
Smoke Detectors 4/14/2022 Approved CRAIG VAUGHAN