1020 1/2 E 83RD ST 90001
Certificate Information: 1020 1/2 E 83RD ST 90001
- Application / Permit
- 21016-10000-19897
- Plan Check / Job No.
- B21LA14291
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT EXISTING DETACHED 3-CAR GARAGE AND WORK ROOM TO ACCESSORY DWELLING UNIT PER LAMC 12.22.A.33(c)-(d) **SEE APPLICATION COMMENTS**
- Permit Issued
- Issued on 10/12/2022
- Issuing Office
- Metro
- Current Status
- Issued on 10/12/2022
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 8/9/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 8/10/2021 | LUKE GONZALES |
| Corrections Issued | 8/10/2021 | LUKE GONZALES |
| Applicant returned to address corrections | 12/29/2021 | GEORGE ALVAREZ |
| Applicant returned to address corrections | 2/20/2022 | FARSHAD ALIMOHAMADI |
| Building Plans Picked Up | 2/23/2022 | APPLICANT |
| Plan Check Approved | 3/8/2022 | JOSEPH RAFOLS |
| Issued | 10/12/2022 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 2/1/2022 | CELINA MORENO |
| Roof/Waste drainage to street | Cleared | 2/1/2022 | CELINA MORENO |
| Sewer availability | Cleared | 2/1/2022 | CELINA MORENO |
| Eng Process Fee Ord 176,300 | Cleared | 2/2/2022 | CELINA MORENO |
| Hydrant and Access approval | Cleared | 3/8/2022 | MENOA AGHAJANI |
| Tenant Habitability Plan | Cleared | 3/8/2022 | TERRI ALEXANDER |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| JOHN QUINTANILLA, (213) 792-6055 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Special/Order Compliance | 2/21/2023 | Corrections Issued | DONALD CRICHLOW |
| Wood Frame | 2/21/2023 | Not Ready for Inspection | ALAN MORELOS |
| Pre-Inspection | 3/1/2023 | Partial Inspection | LILIANA PORTILLO |
| Pre-Inspection | 3/13/2023 | Partial Inspection | LILIANA PORTILLO |
| Footing/Foundation/Slab | 6/28/2023 | Corrections Issued | MICHAEL LEWIS |
| Footing/Foundation/Slab | 10/13/2023 | Corrections Issued | MICHAEL LEWIS |
| Footing/Foundation/Slab | 10/31/2023 | Corrections Issued | MICHAEL LEWIS |
| Wood Frame | 1/14/2025 | Not Ready for Inspection | JOHN QUINTANILLA |
| Wood Frame | 2/5/2025 | Partial Inspection | JOHN QUINTANILLA |
| Interior/Exterior Lathing | 2/20/2025 | Approved | JOHN QUINTANILLA |
| Wood Frame | 2/20/2025 | Partial Inspection | JOHN QUINTANILLA |
| Wood Frame | 6/9/2025 | Not Ready for Inspection | JOHN QUINTANILLA |
| Insulation | 8/19/2025 | Partial Approval | JOHN QUINTANILLA |
| Insulation | 8/27/2025 | No Access for Inspection | ANTHONY RAMOS |
| Insulation | 9/5/2025 | Not Ready for Inspection | RONNIE MEDINA |
| Insulation | 12/9/2025 | Approved | ANTHONY RAMOS |
| Wood Frame | 12/9/2025 | Approved | ANTHONY RAMOS |
| Drywall Nailing | 12/19/2025 | Approved | ANTHONY RAMOS |
| Special/Order Compliance | 12/19/2025 | Approved | ANTHONY RAMOS |
| Final | 2/26/2026 | Corrections Issued | JOHN QUINTANILLA |
| SGSOV-Seismic Gas S/O Valve | 2/26/2026 | SGSOV Not Ready | JOHN QUINTANILLA |
| Smoke Detectors | 2/26/2026 | Approved | JOHN QUINTANILLA |
| Final | 4/23/2026 | Not Ready for Inspection | JOHN QUINTANILLA |
| SGSOV-Seismic Gas S/O Valve | 4/23/2026 | SGSOV Approved | JOHN QUINTANILLA |
| Final | 5/22/2026 | Corrections Issued | RAUL BARAJAS |