2337 N ROSCOMARE ROAD 90077

Certificate Information: 2337 N ROSCOMARE ROAD 90077

Application / Permit
21016-10000-05882
Plan Check / Job No.
B21LA04172
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Commercial
Primary Use
(15) Telecommunication Transmitter - wireless
Work Description
PROPOSED MODIFICATION TO (E) WIRELESS TELECOMMUNICATIONS SITE BY: 1. REPLACE (3) TMBXX (GSM/U19) WITH (3) AIR6449 B41 (L2500+N2500) 2. REPLACE 3 TMBXX (GSM/U19) WITH (3) ROSENBERGER 4FT 2D4WC-21 - 23-PORT ANTENNAS 3. REMOVE (3) RRUS01 B2S AND (3) RRUS11 B2S AND ADD (3) 4424 B25S FOR L19 1ST/L19 AND GSM MIX MODE CONNECT TO 12-PORT **GSM OA ON BETA SECTOR ONLY** 4. REMOVE (3) RRUS11 B4S AND ADD (3) RRU 4415 B66 FOR L21 - CONNECT TO 12-PORT 5. ADD (3) 6X12 HCSS (30M 6AWG EACH) FOR AIR6449S, 4415S, 4424S 6. USE EXISTING BB6630 FOR LTE 7. ADD (1) BB6630 FOR L2500 INSIDE 6131 CABINET 8. ADD (1) BB6648 FOR N2500 INSIDE 6131 CABINET 9. 3X6 HCSS WILL BE IDLE. 10. ADD (1) VOLTAGE BOOSTER (PSU4813) FOR AIR6449S
Permit Issued
Issued on 6/23/2021
Issuing Office
Current Status
Permit Finaled on 9/27/2021

Permit Application Status History

Submitted 3/8/2021 APPLICANT
Assigned to Plan Check Engineer 3/9/2021 CELESTE MORRIS
Corrections Issued 3/11/2021 CELESTE MORRIS
Applicant returned to address corrections 5/13/2021 CELESTE MORRIS
Plan Check Approved 5/25/2021 SINA KHOSRAVI
Building Plans Picked Up 6/16/2021 APPLICANT
Issued 6/23/2021 APPLICANT
Permit Finaled 9/24/2021 DERRICK SPENCER

Permit Application Clearance Information

"Q" conditions Cleared 5/6/2021 ANTONIO ISAIA
"T" removal Cleared 5/6/2021 ANTONIO ISAIA
Plan Approval Cleared 5/6/2021 ANTONIO ISAIA
ZA Case Cleared 5/6/2021 ANTONIO ISAIA
ZA Case Cleared 5/6/2021 ANTONIO ISAIA

Contact Information

Contractor Nuwave International Industries Inc; Lic. No.: 1000182-B 1875 CORONADO AVE      SIGNAL HILL, CA 90755
Engineer O'Sullivan,, Sean Michael; Lic. No.: C84392 25663 VIEW POINTE      LAKE FOREST, CA 92630

Inspector Information

ROGELIO REYNA, (310) 914-3920 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Final 9/24/2021 Permit Finaled DERRICK SPENCER
SGSOV-Seismic Gas S/O Valve 9/24/2021 SGSOV Approved DERRICK SPENCER
Smoke Detectors 9/24/2021 Approved DERRICK SPENCER