667 S LEVERING AVE 1-16 90024

Certificate Information: 667 S LEVERING AVE 1-16 90024

Application / Permit
21016-10000-04325
Plan Check / Job No.
B21LA02936
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
WOOD FRAMING REPAIR AT FIRST AND SECOND FLOOR PURSUANT TO STRUCTURAL FRAMING PLANS PER ENGINEER DESIGN.
Permit Issued
Issued on 4/7/2021
Issuing Office
Current Status
Permit Finaled on 7/28/2021

Permit Application Status History

Submitted 2/18/2021 APPLICANT
Assigned to Plan Check Engineer 2/26/2021 FARSHAD ALIMOHAMADI
Corrections Issued 2/28/2021 FARSHAD ALIMOHAMADI
Building Plans Picked Up 3/3/2021 APPLICANT
Issued 4/7/2021 APPLICANT
Permit Finaled 7/27/2021 GRANT WOODS

Permit Application Clearance Information

Tenant Habitability Plan Cleared 3/3/2021 RICHARD BRINSON

Contact Information

Contractor Saunders Construction Inc; Lic. No.: 616856-B 1760 MONROVIA AVE SUITE A-1      COSTA MESA, CA 92627
Engineer Zargari,, Ramin; Lic. No.: S4119 5010 N PARKWAY CALABASAS 202      CALABASAS, CA 91302

Inspector Information

ROGELIO REYNA, (310) 914-3920 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 5/18/2021 Approved PAUL DAVIDSON
Wood Frame 5/18/2021 Partial Approval PAUL DAVIDSON
Deputy Drilled-In Anchors 5/20/2021 Conditional Approval PAUL DAVIDSON
Floor/Roof Diaphrgm/Shear Wall 5/27/2021 Corrections Issued PAUL DAVIDSON
Wood Frame 5/27/2021 Partial Approval PAUL DAVIDSON
Deputy Wood Construction 6/15/2021 Conditional Approval PAUL DAVIDSON
Floor/Roof Diaphrgm/Shear Wall 6/16/2021 Approved GRANT WOODS
Interior/Exterior Lathing 6/23/2021 Partial Approval GRANT WOODS
Final 7/27/2021 Permit Finaled GRANT WOODS
SGSOV-Seismic Gas S/O Valve 7/27/2021 SGSOV Approved GRANT WOODS
Smoke Detectors 7/27/2021 Approved GRANT WOODS