1652 W LOMITA BLVD 90710

Certificate Information: 1652 W LOMITA BLVD 90710

Application / Permit
21016-10000-01835
Plan Check / Job No.
B21LA01188
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
Soft-Story seismic retrofit per LABC Chapter 93: One Special Steel Cantilevered columns at Tuck Under Parking Area
Permit Issued
Issued on 10/21/2021
Issuing Office
Current Status
CofC Issued on 7/26/2022

Permit Application Status History

Submitted 1/25/2021 APPLICANT
Assigned to Plan Check Engineer 1/28/2021 HANS SANTIAGO
Corrections Issued 2/1/2021 HANS SANTIAGO
Quality Review Completed 2/5/2021 DAVID CHANG
Plan Check Approved 9/16/2021 ANDREW SANTIAGO
Issued 10/21/2021 APPLICANT
OK for CofC 7/8/2022 JOEY BUCHANAN
CofC Issued 7/26/2022 DAVID TSAU

Permit Application Clearance Information

Tenant Habitability Plan Cleared 10/13/2021 PHILLIP MUNGUIA

Contact Information

Contractor Brytin Construction; Lic. No.: 1065160-B 1140 AGNEW STREET      SIMI VALLEY, CA 93065
Engineer Pachunuri,, Nalin Kumar; Lic. No.: C78970 21126 INGOMAR CT      CANOGA PARK, CA 91304

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 11/3/2021 Approved JOEY BUCHANAN
Reinforced Concrete Frame 11/17/2021 Approved JOEY BUCHANAN
Deputy Reinf. Concrete 11/18/2021 Approved JOEY BUCHANAN
Interior/Exterior Lathing 1/6/2022 Approved NICK LAROCCA
Final 7/8/2022 OK for CofC JOEY BUCHANAN
METHANE-Final 7/8/2022 Approved JOEY BUCHANAN
SGSOV-Seismic Gas S/O Valve 7/8/2022 SGSOV Approved JOEY BUCHANAN
Smoke Detectors 7/8/2022 Approved JOEY BUCHANAN