329-331 W 8TH ST 90731
Certificate Information: 329-331 W 8TH ST 90731
- Application / Permit
- 21016-10000-01446
- Plan Check / Job No.
- B21LA00961
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- Convert portion of (E) one-story Single Family Dwelling to Accessory Dwelling Unit per GCS 65852.2(e)(1)(A). No increase in floor area. All work per WFPP.
- Permit Issued
- Issued on 7/29/2021
- Issuing Office
- Current Status
- CofO Issued on 12/18/2021
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/20/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 2/1/2021 | TSE MING HUANG |
| Corrections Issued | 2/3/2021 | TSE MING HUANG |
| Applicant returned to address corrections | 3/3/2021 | SAMUEL GONZALEZ |
| Applicant returned to address corrections | 4/8/2021 | CRYSTEL MAALOUF |
| Building Plans Picked Up | 4/9/2021 | APPLICANT |
| Plan Check Approved | 7/28/2021 | JESSE VIDUYA |
| Issued | 7/29/2021 | APPLICANT |
| CofO in Progress | 12/4/2021 | ANSON MAGLASANG |
| Permit Finaled | 12/18/2021 | DEROLD HAUFF |
| CofO Issued | 12/18/2021 | DEROLD HAUFF |
| Permit Finaled | 12/18/2021 | DEROLD HAUFF |
Permit Application Clearance Information
| Address approval | Cleared | 4/6/2021 | CHINH DINH |
| Eng Process Fee Ord 176,300 | Cleared | 4/7/2021 | CHINH DINH |
| Sewer availability | Cleared | 4/7/2021 | CHINH DINH |
| Redevelopment Project Area | Cleared | 4/9/2021 | GRACIELA ACOSTA |
| Tenant Habitability Plan | Cleared | 4/14/2021 | RICHARD BRINSON |
| Community Plan Implem. Overlay | Cleared | 4/16/2021 | JEANALEE OBERGFELL |
| Miscellaneous | Cleared | 4/26/2021 | KENTON TRINH |
| Hydrant and Access approval | Cleared | 5/24/2021 | MATTHEW CRAIG |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| JOSEPH MCGARRY, (310) 732-4559 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 8/2/2021 | Partial Inspection | ANSON MAGLASANG |
| BUILDING-Rough-Frame | 8/4/2021 | Not Ready for Inspection | ANSON MAGLASANG |
| ELECTRICAL-Rough | 8/4/2021 | Approved | ANSON MAGLASANG |
| Gas Test | 8/4/2021 | Approved | ANSON MAGLASANG |
| PLUMBING-Rough | 8/4/2021 | Corrections Issued | ANSON MAGLASANG |
| Rough-Elec/Plmb/HVAC | 8/4/2021 | Not Ready for Inspection | ANSON MAGLASANG |
| Sewer | 8/4/2021 | Not Ready for Inspection | ANSON MAGLASANG |
| Wood Frame | 8/4/2021 | Not Ready for Inspection | ANSON MAGLASANG |
| Special/Order Compliance | 8/6/2021 | Not Ready for Inspection | JOHN KLARIN |
| ELECTRICAL-Rough | 8/10/2021 | Not Ready for Inspection | CRAIG DAVIS |
| PLUMBING-Rough | 8/10/2021 | Not Ready for Inspection | CRAIG DAVIS |
| Sewer | 8/10/2021 | Not Ready for Inspection | CRAIG DAVIS |
| Wood Frame | 8/10/2021 | Not Ready for Inspection | CRAIG DAVIS |
| PLUMBING-Rough | 8/11/2021 | Corrections Issued | JOHN KLARIN |
| Sewer | 8/11/2021 | No Access for Inspection | CRAIG DAVIS |
| Special/Order Compliance | 8/18/2021 | Corrections Issued | JOHN KLARIN |
| Special/Order Compliance | 8/19/2021 | Not Ready for Inspection | JOHN KLARIN |
| Insulation | 8/23/2021 | Partial Approval | JOHN KLARIN |
| PLUMBING-Rough | 8/23/2021 | Approved | JOHN KLARIN |
| Sewer | 8/23/2021 | Approved | JOHN KLARIN |
| Insulation | 8/26/2021 | Approved | ANSON MAGLASANG |
| Drywall Nailing | 9/7/2021 | Approved | ANSON MAGLASANG |
| Shower Pan | 9/21/2021 | Approved | ANSON MAGLASANG |
| Special/Order Compliance | 10/1/2021 | Corrections Issued | JOHN KLARIN |
| Special/Order Compliance | 10/7/2021 | Approved | ANSON MAGLASANG |
| BUILDING-Rough-Frame | 11/10/2021 | Approved | ANSON MAGLASANG |
| Final | 11/10/2021 | Corrections Issued | ANSON MAGLASANG |
| SGSOV-Seismic Gas S/O Valve | 11/10/2021 | SGSOV Not Ready | ANSON MAGLASANG |
| Smoke Detectors | 11/10/2021 | Not Ready for Inspection | ANSON MAGLASANG |
| Final | 11/19/2021 | Corrections Issued | ANSON MAGLASANG |
| SGSOV-Seismic Gas S/O Valve | 11/19/2021 | SGSOV Approved | ANSON MAGLASANG |
| Smoke Detectors | 11/19/2021 | Approved | ANSON MAGLASANG |
| Final | 11/24/2021 | OK to Issue CofO | ANSON MAGLASANG |