3115-3117 S GLENDON AVE 90034
Certificate Information: 3115-3117 S GLENDON AVE 90034
- Application / Permit
- 21014-30000-05842
- Plan Check / Job No.
- B21WL05145
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Junior Accessory Dwelling Unit
- Work Description
- Addition to a single family home and conversion of the garage into a JADU.
- Permit Issued
- Issued on 8/5/2022
- Issuing Office
- West Los Angeles
- Current Status
- CofO Issued on 5/22/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/19/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 11/24/2021 | RICHARD GARCIA |
| Corrections Issued | 11/28/2021 | RICHARD GARCIA |
| Applicant returned to address corrections | 1/15/2022 | RICHARD GARCIA |
| Plan Check Approved | 2/22/2022 | RICHARD GARCIA |
| Building Plans Picked Up | 2/24/2022 | APPLICANT |
| Issued | 8/5/2022 | APPLICANT |
| CofO in Progress | 5/16/2024 | JESUS PINEDA |
| Permit Finaled | 5/22/2024 | DANIEL ORRANTE |
| CofO Issued | 5/22/2024 | DANIEL ORRANTE |
| Permit Finaled | 5/22/2024 | DANIEL ORRANTE |
Permit Application Clearance Information
| Address approval | Cleared | 12/11/2021 | JOSE HERNANDEZ |
| Sewer availability | Cleared | 12/11/2021 | JOSE HERNANDEZ |
| Eng Process Fee Ord 176,300 | Cleared | 12/13/2021 | JOSE HERNANDEZ |
| Roof/Waste drainage to street | Cleared | 12/13/2021 | JOSE HERNANDEZ |
| Specific Plan | Cleared | 12/14/2021 | RUBEN VASQUEZ |
| ZI | Cleared | 12/14/2021 | RUBEN VASQUEZ |
| ZI | Cleared | 12/14/2021 | RUBEN VASQUEZ |
| Specific Plan | Cleared | 12/21/2021 | VALERIA CEJA |
| Grading Pre-Inspection | Cleared | 1/25/2022 | RICHARD GARCIA |
Contact Information
| Architect | Noteware,, Brian Arthur; Lic. No.: C21514 | 845 20TH STREET, #106 SANTA MONICA, CA 90403 |
| Contractor | True North Designs; Lic. No.: 541817-B | 12430 MITCHELL AVENUE LOS ANGELES, CA 90066 |
Inspector Information
| KIRK SANDERS, (310) 914-3896 | Office Hours: 7:00-8:00 AM MON-FRI |
| ARAM AVEDISIAN, (310) 914-3896 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Grading Pre-Inspection | 9/9/2022 | Partial Approval | JOHNNY MIRANDA |
| Pre-Inspection | 9/9/2022 | Partial Approval | JOHNNY MIRANDA |
| Deputy Drilled-In Anchors | 9/28/2022 | Conditional Approval | MICHAEL PELHAM |
| Footing/Foundation/Slab | 9/29/2022 | Corrections Issued | JOHNNY MIRANDA |
| Footing/Foundation/Slab | 10/3/2022 | Partial Approval | JOHNNY MIRANDA |
| PLUMBING-Rough | 10/12/2022 | Partial Approval | JOHNNY MIRANDA |
| Wood Frame | 10/12/2022 | Partial Approval | JOHNNY MIRANDA |
| Floor/Roof Diaphrgm/Shear Wall | 10/14/2022 | Partial Approval | CLAYTON GRAHAM |
| ELECTRICAL-Rough | 11/8/2022 | Partial Approval | JOHNNY MIRANDA |
| Floor/Roof Diaphrgm/Shear Wall | 11/8/2022 | Partial Approval | JOHNNY MIRANDA |
| PLUMBING-Rough | 11/8/2022 | Partial Approval | JOHNNY MIRANDA |
| Underground Mechanical | 11/8/2022 | Not Ready for Inspection | JOHNNY MIRANDA |
| Wood Frame | 11/8/2022 | Not Ready for Inspection | JOHNNY MIRANDA |
| Deputy Wood Construction | 11/9/2022 | Conditional Approval | MICHAEL PELHAM |
| Floor/Roof Diaphrgm/Shear Wall | 11/10/2022 | Partial Approval | JOHNNY MIRANDA |
| Floor/Roof Diaphrgm/Shear Wall | 11/16/2022 | Partial Approval | JOHNNY MIRANDA |
| Interior/Exterior Lathing | 11/16/2022 | Partial Approval | JOHNNY MIRANDA |
| Floor/Roof Diaphrgm/Shear Wall | 11/18/2022 | Partial Approval | JOHNNY MIRANDA |
| BUILDING-Rough-Frame | 2/9/2023 | Corrections Issued | HERBERT GIRON |
| ELECTRICAL-Rough | 2/9/2023 | Corrections Issued | HERBERT GIRON |
| Green Building Rough | 2/9/2023 | Not Ready for Inspection | HERBERT GIRON |
| HVAC-Rough | 2/9/2023 | Corrections Issued | HERBERT GIRON |
| MERV13>=Rough | 2/9/2023 | Not Ready for Inspection | HERBERT GIRON |
| PLUMBING-Rough | 2/9/2023 | Approved | HERBERT GIRON |
| BUILDING-Rough-Frame | 2/17/2023 | Approved | JOHNNY MIRANDA |
| ELECTRICAL-Rough | 2/17/2023 | Approved | JOHNNY MIRANDA |
| Green Building Rough | 2/17/2023 | Approved | JOHNNY MIRANDA |
| HVAC-Rough | 2/17/2023 | Approved | JOHNNY MIRANDA |
| MERV13>=Rough | 2/17/2023 | Approved | JOHNNY MIRANDA |
| PLUMBING-Rough | 2/17/2023 | Approved | JOHNNY MIRANDA |
| Insulation | 2/23/2023 | Approved | JOHNNY MIRANDA |
| Drywall Nailing | 3/2/2023 | Approved | JOHNNY MIRANDA |
| Shower Pan | 4/11/2023 | Corrections Issued | DAVID FEILER |
| Shower Pan | 4/14/2023 | Not Ready for Inspection | JOHNNY MIRANDA |
| Interior/Exterior Lathing | 4/18/2023 | Approved | JESUS RODRIGUEZ |
| Shower Pan | 4/18/2023 | Approved | JESUS RODRIGUEZ |
| Rough-Elec/Plmb/HVAC | 9/14/2023 | Approved | BEN MOLSTAD |
| Final | 12/22/2023 | Corrections Issued | JESUS PINEDA |
| Footing/Foundation/Slab | 12/22/2023 | Approved | JESUS PINEDA |
| Green Building Final | 12/22/2023 | Approved | JESUS PINEDA |
| MERV13>=Final | 12/22/2023 | Approved | JESUS PINEDA |
| SGSOV-Seismic Gas S/O Valve | 12/22/2023 | SGSOV Approved | JESUS PINEDA |
| Smoke Detectors | 12/22/2023 | Approved | JESUS PINEDA |
| Final | 5/16/2024 | OK to Issue CofO | JESUS PINEDA |