212 N COPA DE ORO ROAD 90077

Certificate Information: 212 N COPA DE ORO ROAD 90077

Application / Permit
21014-30000-03128
Plan Check / Job No.
B21WL02732
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
Remodel and- Addition to an (E) 2-Story S.F.D, Replacement of Carport with Attached Garage and Covered Loggia *** 1 of 2 ***
Permit Issued
Issued on 7/13/2022
Issuing Office
Current Status
CofO Issued on 11/22/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 6/22/2021 APPLICANT
Assigned to Plan Check Engineer 7/8/2021 DAVID CASTILLO
Corrections Issued 7/13/2021 DAVID CASTILLO
Quality Review Completed 7/28/2021 CHIHARU SUZUKI
Applicant returned to address corrections 12/8/2021 DAVID CASTILLO
Applicant returned to address corrections 2/2/2022 DAVID CASTILLO
Building Plans Picked Up 2/3/2022 APPLICANT
Plan Check Approved 7/1/2022 DAVID CASTILLO
Issued 7/13/2022 APPLICANT
CofO in Progress 11/22/2024 MICHAEL PELHAM
Permit Finaled 11/22/2024 RICHARD STEINBACH
CofO Issued 11/22/2024 RICHARD STEINBACH
Permit Finaled 11/22/2024 RICHARD STEINBACH

Permit Application Clearance Information

BHO/Hillside ordinance Cleared 9/30/2021 SAUL GARCIA
BHO/Hillside ordinance Cleared 9/30/2021 SAUL GARCIA
BHO/Hillside ordinance Cleared 9/30/2021 SAUL GARCIA
BHO/Hillside ordinance Cleared 9/30/2021 SAUL GARCIA
Sewer availability Cleared 9/30/2021 SAUL GARCIA
Permit Cleared 10/1/2021 SAUL GARCIA
Hydrant and Access approval Cleared 10/2/2021 GILBERT URREA
Eng Process Fee Ord 176,300 Cleared 10/13/2021 SAUL GARCIA
Trees in Parkway Cleared 11/17/2021 ADALBERTO VERA
Grading Pre-Inspection Cleared 12/8/2021 DAVID CASTILLO
BHO/Hillside ordinance Cleared 12/13/2021 RAYMOND MUGAMBWA
ZI Cleared 1/25/2022 RICHARD REASER
Excavation more than 5-ft deep Cleared 2/2/2022 CALOSHA APPROVED
Low Impact Development Cleared 4/8/2022 CHRIS VONG
Roof/Waste drainage to street Cleared 4/15/2022 RAYMOND MUGAMBWA

Contact Information

Architect Manion,, Richard M; Lic. No.: C26957 11400 WEST OLYMPIC BLVD SUITE 410      LOS ANGELES, CA 90025
Contractor Utopia Development Inc; Lic. No.: 710612-B 2371 E 51ST STREET      VERNON, CA 90058
Engineer Amoroso,, Gregory Michael; Lic. No.: L8771 24269 PALO VERDE DR      VALENCIA, CA 91354
Engineer Danz,, Joshua Franklin; Lic. No.: C84764 1164 ELDERBERRY CIRCLE      FOLSOM, CA 95630
Engineer Hollingsworth,, Robert Alan; Lic. No.: GE2022 31129 VIA COLINAS SUITE 707      WESTLAKE VILLAGE, CA 91362
Engineer Yamini,, Soly; Lic. No.: C33719 540 WARNER AVE      LOS ANGELES, CA 90024
Geologist Hollingsworth,, Robert Alan; Lic. No.: EG1265 31129 VIA COLINAS SUITE 707      WESTLAKE VILLAGE, CA 91362
Landscape Architect Truskowski,, Robert E; Lic. No.: LA1328 1110 NORTH COAST HIGHWAY      LAGUNA BEACH, CA 92651

Inspector Information

RYAN SALAZAR, (310) 914-3862 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 8/16/2022 Partial Approval CHRISTOPHER WILSON
Footing/Foundation/Slab 9/7/2022 Approved CHRISTOPHER WILSON
Pre-Inspection 9/13/2022 Partial Approval CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 9/22/2022 Partial Approval CHRISTOPHER WILSON
Structural Steel Frame 9/27/2022 Not Ready for Inspection CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 10/5/2022 Partial Approval CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 10/17/2022 Partial Approval CARLOS MATAMOROS
Excavation/Setback/Form/Re-Bar 10/24/2022 Partial Approval CHRISTOPHER WILSON
PLUMBING-Rough 10/24/2022 Corrections Issued CHRISTOPHER WILSON
Sewer 10/24/2022 Not Ready for Inspection CHRISTOPHER WILSON
PLUMBING-Rough 11/7/2022 Not Ready for Inspection CHRISTOPHER WILSON
PLUMBING-Rough 11/9/2022 Partial Approval CHRISTOPHER WILSON
PLUMBING-Rough 11/17/2022 Partial Approval CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 11/22/2022 Partial Approval CARLOS MATAMOROS
Deputy Drilled-In Anchors 12/2/2022 Conditional Approval MICHAEL PELHAM
Deputy Steel/Welding 12/2/2022 Conditional Approval MICHAEL PELHAM
Excavation/Setback/Form/Re-Bar 12/8/2022 Partial Approval CHRISTOPHER WILSON
Structural Steel Frame 12/8/2022 Corrections Issued CHRISTOPHER WILSON
Floor/Roof Diaphrgm/Shear Wall 12/16/2022 Partial Approval CHRISTOPHER WILSON
Structural Steel Frame 12/16/2022 Approved CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 12/20/2022 Approved CHRISTOPHER WILSON
Footing/Foundation/Slab 12/20/2022 Approved CHRISTOPHER WILSON
Pre-Inspection 12/20/2022 Partial Approval CHRISTOPHER WILSON
BUILDING-Rough-Frame 1/12/2023 Not Ready for Inspection GERMAN RODRIGUEZ MENDOZA
Floor/Roof Diaphrgm/Shear Wall 1/12/2023 Partial Approval GERMAN RODRIGUEZ MENDOZA
Green Building Rough 1/12/2023 Not Ready for Inspection GERMAN RODRIGUEZ MENDOZA
Wood Frame 1/12/2023 Not Ready for Inspection GERMAN RODRIGUEZ MENDOZA
BUILDING-Rough-Frame 1/26/2023 Partial Approval CHRISTOPHER WILSON
Green Building Rough 1/26/2023 Partial Approval CHRISTOPHER WILSON
Light Gage Steel Frame 1/26/2023 Partial Approval CHRISTOPHER WILSON
Wood Frame 1/26/2023 Partial Approval CHRISTOPHER WILSON
Excavation/Setback/Form/Re-Bar 2/15/2023 Approved CHRISTOPHER WILSON
Footing/Foundation/Slab 2/15/2023 Partial Approval CHRISTOPHER WILSON
HVAC-Rough 4/19/2023 Corrections Issued GERMAN RODRIGUEZ MENDOZA
PLUMBING-Rough 4/28/2023 Corrections Issued CHRISTOPHER WILSON
Sewer 4/28/2023 Not Ready for Inspection CHRISTOPHER WILSON
PLUMBING-Rough 5/2/2023 Partial Approval CHRISTOPHER WILSON
HVAC-Rough 5/4/2023 Partial Approval CHRISTOPHER WILSON
HVAC-Rough 5/31/2023 Corrections Issued CHRISTOPHER WILSON
HVAC-Rough 6/8/2023 Approved CHRISTOPHER WILSON
ELECTRICAL-Rough 6/21/2023 Not Ready for Inspection CHRISTOPHER WILSON
PLUMBING-Rough 6/21/2023 Approved CHRISTOPHER WILSON
ELECTRICAL-Rough 6/26/2023 Corrections Issued CHRISTOPHER WILSON
Gas Test 6/27/2023 Partial Approval CHRISTOPHER WILSON
ELECTRICAL-Rough 6/30/2023 Partial Approval CHRISTOPHER WILSON
Interior/Exterior Lathing 6/30/2023 Partial Approval CHRISTOPHER WILSON
Gas Test 7/5/2023 Corrections Issued CHRISTOPHER WILSON
Gas Test 7/10/2023 Partial Approval CHRISTOPHER WILSON
BUILDING-Rough-Frame 7/12/2023 Corrections Issued CHRISTOPHER WILSON
BUILDING-Rough-Frame 7/14/2023 Partial Approval CHRISTOPHER WILSON
Drywall Nailing 7/25/2023 Not Ready for Inspection BRENDAN LOONEY
Green Building Rough 7/25/2023 Not Ready for Inspection BRENDAN LOONEY
ELECTRICAL-Rough 7/28/2023 Partial Approval CHRISTOPHER WILSON
Insulation 7/28/2023 Partial Approval CHRISTOPHER WILSON
BUILDING-Rough-Frame 8/1/2023 Corrections Issued CHRISTOPHER WILSON
Drywall Nailing 8/1/2023 Partial Approval CHRISTOPHER WILSON
Green Building Rough 8/1/2023 Approved CHRISTOPHER WILSON
Interior/Exterior Lathing 8/1/2023 Partial Approval CHRISTOPHER WILSON
Shower Pan 8/1/2023 Partial Approval CHRISTOPHER WILSON
BUILDING-Rough-Frame 8/2/2023 Approved CHRISTOPHER WILSON
Insulation 8/8/2023 Partial Approval CHRISTOPHER WILSON
Shower Pan 8/8/2023 Approved CHRISTOPHER WILSON
Drywall Nailing 9/6/2023 Partial Approval CHRISTOPHER WILSON
Interior/Exterior Lathing 9/11/2023 Partial Approval CHRISTOPHER WILSON
Drywall Nailing 9/18/2023 Partial Approval CHRISTOPHER WILSON
Interior/Exterior Lathing 11/28/2023 Approved CHRISTOPHER WILSON
ELECTRICAL-Rough 4/24/2024 Not Ready for Inspection CHRISTOPHER WILSON
Underground Mechanical 4/24/2024 Corrections Issued CHRISTOPHER WILSON
Underground Mechanical 4/26/2024 Corrections Issued CHRISTOPHER WILSON
Underground Mechanical 5/10/2024 Approved CHRISTOPHER WILSON
PLUMBING-Final 5/15/2024 Corrections Issued CHRISTOPHER WILSON
Grounding or Bonding 7/5/2024 Corrections Issued CHRISTOPHER WILSON
Grounding or Bonding 7/8/2024 Corrections Issued CHRISTOPHER WILSON
ELECTRICAL-Final 7/18/2024 Not Ready for Inspection CHRISTOPHER WILSON
Service/Power Release 7/19/2024 Approved CHRISTOPHER WILSON
Gas Test 7/30/2024 Corrections Issued CHRISTOPHER WILSON
PLUMBING-Rough 7/30/2024 Not Ready for Inspection CHRISTOPHER WILSON
SGSOV-Seismic Gas S/O Valve 9/6/2024 SGSOV Approved CHRISTOPHER WILSON
HVAC-Final 9/25/2024 Corrections Issued CHRISTOPHER WILSON
ELECTRICAL-Final 10/11/2024 Corrections Issued CHRISTOPHER WILSON
HVAC-Final 10/11/2024 Corrections Issued CHRISTOPHER WILSON
ELECTRICAL-Final 10/17/2024 Approved CARLOS MATAMOROS
HVAC-Final 10/17/2024 Approved CARLOS MATAMOROS
Drywall Nailing 11/12/2024 Approved CHRISTOPHER WILSON
Final 11/12/2024 Corrections Issued CHRISTOPHER WILSON
Footing/Foundation/Slab 11/12/2024 Approved CHRISTOPHER WILSON
Green Building Final 11/12/2024 Approved CHRISTOPHER WILSON
PLUMBING-Final 11/12/2024 Approved CHRISTOPHER WILSON
Smoke Detectors 11/12/2024 Approved CHRISTOPHER WILSON
Deputy Drilled-In Anchors 11/22/2024 Approved MICHAEL PELHAM
Final 11/22/2024 OK to Issue CofO MICHAEL PELHAM