5229 N HERMOSA AVE 90041
Certificate Information: 5229 N HERMOSA AVE 90041
- Application / Permit
- 21014-20000-06196
- Plan Check / Job No.
- B21VN17247
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ADDITION OF A 19' X 20' REC. ROOM TO THE (E) SINGLE FAMILY DWELLING. ALL WORK PER ENGINEERING.
- Permit Issued
- Issued on 1/24/2022
- Issuing Office
- Current Status
- CofO Issued on 6/14/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/13/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 12/14/2021 | COLIN LOREDO |
| Corrections Issued | 12/17/2021 | COLIN LOREDO |
| Building Plans Picked Up | 12/21/2021 | APPLICANT |
| Plan Check Approved | 1/24/2022 | COLIN LOREDO |
| Issued | 1/24/2022 | APPLICANT |
| CofO in Progress | 6/1/2022 | CRAIG VAUGHAN |
| CofO in Progress | 6/1/2022 | CRAIG VAUGHAN |
| Permit Finaled | 6/14/2022 | DEROLD HAUFF |
| CofO Issued | 6/14/2022 | DEROLD HAUFF |
| Permit Finaled | 6/14/2022 | DEROLD HAUFF |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 12/28/2021 | CELINA MORENO |
| Sewer availability | Cleared | 12/28/2021 | CELINA MORENO |
| Grading Pre-Inspection | Cleared | 12/29/2021 | BRIAN MILLER |
| Eng Process Fee Ord 176,300 | Cleared | 1/4/2022 | CELINA MORENO |
| GPI Written Notices | Cleared | 1/24/2022 | COLIN LOREDO |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Medina,, Armando; Lic. No.: C83911 | 121 N VAIL AVE MONTEBELLO, CA 90640 |
Inspector Information
| RONNIE MEDINA, (213) 469-5852 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 2/16/2022 | Conditional Approval | HAMIK HARTOUNIAN |
| Excavation/Setback/Form/Re-Bar | 2/17/2022 | Approved | CRAIG VAUGHAN |
| Deputy Wood Construction | 3/11/2022 | Conditional Approval | CRAIG VAUGHAN |
| BUILDING-Rough-Frame | 3/14/2022 | Partial Approval | CRAIG VAUGHAN |
| ELECTRICAL-Rough | 3/14/2022 | Approved | CRAIG VAUGHAN |
| Green Building Rough | 3/14/2022 | Approved | CRAIG VAUGHAN |
| HVAC-Rough | 3/14/2022 | Approved | CRAIG VAUGHAN |
| PLUMBING-Rough | 3/14/2022 | Corrections Issued | CRAIG VAUGHAN |
| BUILDING-Rough-Frame | 3/17/2022 | Corrections Issued | SCOTT FINNILA |
| Interior/Exterior Lathing | 3/17/2022 | Partial Approval | HAMIK HARTOUNIAN |
| PLUMBING-Rough | 3/17/2022 | Approved | HAMIK HARTOUNIAN |
| PLUMBING-Rough | 3/17/2022 | Approved | SCOTT FINNILA |
| BUILDING-Rough-Frame | 3/22/2022 | Approved | CRAIG VAUGHAN |
| Wood Frame | 3/22/2022 | Approved | CRAIG VAUGHAN |
| Insulation | 3/29/2022 | Approved | CHARLES BOGHOSKHAN |
| Drywall Nailing | 4/1/2022 | Approved | CRAIG VAUGHAN |
| Final | 5/16/2022 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Footing/Foundation/Slab | 5/16/2022 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Green Building Final | 5/16/2022 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| SGSOV-Seismic Gas S/O Valve | 5/16/2022 | SGSOV Approved | HAMIK HARTOUNIAN |
| Smoke Detectors | 5/16/2022 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Final | 5/24/2022 | Corrections Issued | CRAIG VAUGHAN |
| Footing/Foundation/Slab | 5/24/2022 | Approved | CRAIG VAUGHAN |
| Green Building Final | 5/24/2022 | Approved | CRAIG VAUGHAN |
| Smoke Detectors | 5/24/2022 | Not Ready for Inspection | CRAIG VAUGHAN |
| ELECTRICAL-Final | 5/31/2022 | Approved | CRAIG VAUGHAN |
| Final | 5/31/2022 | OK to Issue CofO | CRAIG VAUGHAN |
| HVAC-Final | 5/31/2022 | Approved | CRAIG VAUGHAN |
| PLUMBING-Final | 5/31/2022 | Approved | CRAIG VAUGHAN |
| Smoke Detectors | 5/31/2022 | Approved | CRAIG VAUGHAN |