1215 W R ST 90744

Certificate Information: 1215 W R ST 90744

Application / Permit
21014-20000-04531
Plan Check / Job No.
B21VN12097
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
ECPC: 19'8" X 31' 11 1/2" IRREGULAR SHAPE ADDITION OF TWO BEDROOMS AND TWO BATHROOMS TO THE (E) SFD. ALL WORK PER ENGINEER. " NFPA- 13D FIRE SPRINKLER IS REQUIRED."
Permit Issued
Issued on 2/3/2022
Issuing Office
Current Status
Issued on 2/3/2022
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 9/23/2021 APPLICANT
Assigned to Plan Check Engineer 9/24/2021 PINANK PATEL
Corrections Issued 9/27/2021 PINANK PATEL
Applicant returned to address corrections 10/21/2021 PINANK PATEL
Applicant returned to address corrections 12/27/2021 PINANK PATEL
Applicant returned to address corrections 1/24/2022 PINANK PATEL
Plan Check Approved 1/31/2022 PINANK PATEL
Issued 2/3/2022 APPLICANT
Building Plans Picked Up 2/10/2022 APPLICANT

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 10/12/2021 JOSE HERNANDEZ
Sewer availability Cleared 10/12/2021 JOSE HERNANDEZ
Roof/Waste drainage to street Cleared 1/31/2022 JOSE HERNANDEZ

Contact Information

Contractor Treeium Inc; Lic. No.: 617148-B 5352 LAUREL CANYON BLVD #200      VALLEY VILLAGE, CA 91607
Engineer Keshishian,, Anthony; Lic. No.: C89551 2654 RISA D      GLENDALE, CA 91208

Inspector Information

EUGENE CASSIDY, (310) 548-2508 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 2/22/2022 Corrections Issued EUGENE CASSIDY
Pre-Inspection 2/22/2022 Not Ready for Inspection EUGENE CASSIDY
Excavation/Setback/Form/Re-Bar 3/16/2022 Corrections Issued EUGENE CASSIDY
Pre-Inspection 3/16/2022 Not Ready for Inspection EUGENE CASSIDY
Excavation/Setback/Form/Re-Bar 5/3/2022 Corrections Issued EUGENE CASSIDY
Footing/Foundation/Slab 5/3/2022 Not Ready for Inspection EUGENE CASSIDY
METHANE-Barrier 5/3/2022 Approved EUGENE CASSIDY
METHANE-Subgrade 5/3/2022 Approved EUGENE CASSIDY
Deputy Wood Construction 5/10/2022 Approved DONALD CRICHLOW
Excavation/Setback/Form/Re-Bar 5/12/2022 Approved EUGENE CASSIDY
Pre-Inspection 5/12/2022 Approved EUGENE CASSIDY
Excavation/Setback/Form/Re-Bar 5/25/2022 Approved EUGENE CASSIDY
Floor/Roof Diaphrgm/Shear Wall 5/25/2022 Corrections Issued EUGENE CASSIDY
Footing/Foundation/Slab 5/25/2022 Approved EUGENE CASSIDY
Excavation/Setback/Form/Re-Bar 6/2/2022 Approved EUGENE CASSIDY
Floor/Roof Diaphrgm/Shear Wall 6/2/2022 Partial Approval EUGENE CASSIDY
PLUMBING-Rough 6/2/2022 Partial Approval EUGENE CASSIDY
Drywall Nailing 6/6/2022 Not Ready for Inspection EUGENE CASSIDY
Insulation 6/6/2022 Partial Approval EUGENE CASSIDY
Floor/Roof Diaphrgm/Shear Wall 6/7/2022 Partial Approval EUGENE CASSIDY
Drywall Nailing 7/15/2022 Not Ready for Inspection EUGENE CASSIDY
Floor/Roof Diaphrgm/Shear Wall 7/15/2022 Partial Approval EUGENE CASSIDY
BUILDING-Rough-Frame 8/22/2022 Corrections Issued EUGENE CASSIDY
ELECTRICAL-Rough 8/22/2022 Not Ready for Inspection EUGENE CASSIDY
Green Building Rough 8/22/2022 Not Ready for Inspection EUGENE CASSIDY
METHANE-Rough 8/22/2022 Approved EUGENE CASSIDY
PLUMBING-Rough 8/22/2022 Approved EUGENE CASSIDY
BUILDING-Rough-Frame 8/26/2022 Not Ready for Inspection EUGENE CASSIDY
ELECTRICAL-Rough 8/26/2022 Corrections Issued EUGENE CASSIDY
Green Building Rough 8/26/2022 Not Ready for Inspection EUGENE CASSIDY
BUILDING-Rough-Frame 9/6/2022 Partial Approval EUGENE CASSIDY
ELECTRICAL-Rough 9/6/2022 Approved EUGENE CASSIDY
Green Building Rough 9/6/2022 Not Ready for Inspection EUGENE CASSIDY
HVAC-Rough 9/6/2022 Approved EUGENE CASSIDY
Pre-Inspection 9/16/2022 Approved EUGENE CASSIDY
BUILDING-Rough-Frame 11/1/2022 Corrections Issued EUGENE CASSIDY
Green Building Rough 11/1/2022 Not Ready for Inspection EUGENE CASSIDY
BUILDING-Rough-Frame 11/9/2022 Approved EUGENE CASSIDY
Green Building Rough 11/9/2022 Approved EUGENE CASSIDY
Insulation 11/9/2022 Approved EUGENE CASSIDY
Interior/Exterior Lathing 11/9/2022 Partial Approval EUGENE CASSIDY
Drywall Nailing 11/14/2022 Approved EUGENE CASSIDY
Final 1/9/2024 Corrections Issued EUGENE CASSIDY
Green Building Final 1/9/2024 Approved EUGENE CASSIDY
SGSOV-Seismic Gas S/O Valve 1/9/2024 SGSOV Approved EUGENE CASSIDY
Smoke Detectors 1/9/2024 Not Ready for Inspection EUGENE CASSIDY