3611 S POTOMAC AVE 90016
Certificate Information: 3611 S POTOMAC AVE 90016
- Application / Permit
- 21014-20000-04328
- Plan Check / Job No.
- B21VN11550
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 14'-1" X 13' AND 19'- 6 1/2" X 8' ADDITIONS TO (E) SINGLE FAMILY DWELLING AND REMODEL TO BEDROOMS, BATHROOMS, LIVING ROOM, AND KITCHEN. ALL WORK PER ENGINEEING.
- Permit Issued
- Issued on 10/20/2021
- Issuing Office
- Current Status
- CofO Issued on 10/17/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/25/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 9/2/2021 | OMAR GARNICA |
| Corrections Issued | 9/4/2021 | OMAR GARNICA |
| Applicant returned to address corrections | 10/12/2021 | OMAR GARNICA |
| Plan Check Approved | 10/20/2021 | OMAR GARNICA |
| Issued | 10/20/2021 | APPLICANT |
| Building Plans Picked Up | 10/21/2021 | APPLICANT |
| CofO in Progress | 9/14/2022 | ANTHONY EGSON |
| Permit Finaled | 10/17/2022 | DEROLD HAUFF |
| CofO Issued | 10/17/2022 | DEROLD HAUFF |
| Permit Finaled | 10/17/2022 | DEROLD HAUFF |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 10/18/2021 | STEVE MELGAR |
| Eng Process Fee Ord 176,300 | Cleared | 10/19/2021 | STEVE MELGAR |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Maalouf,, Sami; Lic. No.: C53210 | 15445 VENTURA BLVD STE 367 SHERMAN OAKS, CA 91403 |
Inspector Information
| LUIS CASTRO, (213) 202-3436 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 10/26/2021 | Corrections Issued | ANTHONY EGSON |
| Floor/Roof Diaphrgm/Shear Wall | 11/5/2021 | Order to Comply Issued | ANTHONY EGSON |
| Footing/Foundation/Slab | 11/5/2021 | Corrections Issued | ANTHONY EGSON |
| Floor/Roof Diaphrgm/Shear Wall | 11/16/2021 | Corrections Issued | ANTHONY EGSON |
| Footing/Foundation/Slab | 11/16/2021 | Corrections Issued | ANTHONY EGSON |
| Special/Order Compliance | 11/16/2021 | Not Ready for Inspection | HORACE FULTZ |
| Insulation | 11/30/2021 | Partial Approval | ANTHONY EGSON |
| Underground Mechanical | 12/3/2021 | Approved | ANTHONY EGSON |
| Deputy Drilled-In Anchors | 12/7/2021 | Conditional Approval | SHAVONNE ESPINOZA |
| Deputy Other (see comments) | 12/7/2021 | Conditional Approval | SHAVONNE ESPINOZA |
| Floor/Roof Diaphrgm/Shear Wall | 12/9/2021 | Approved | ANTHONY EGSON |
| Floor/Roof Diaphrgm/Shear Wall | 1/31/2022 | Approved | ANTHONY EGSON |
| BUILDING-Rough-Frame | 2/9/2022 | Order to Comply Issued | JOSEPH MCGARRY |
| ELECTRICAL-Rough | 2/9/2022 | Approved | JOSEPH MCGARRY |
| Green Building Rough | 2/9/2022 | Approved | JOSEPH MCGARRY |
| HVAC-Rough | 2/9/2022 | Approved | JOSEPH MCGARRY |
| PLUMBING-Rough | 2/9/2022 | Approved | JOSEPH MCGARRY |
| Insulation | 2/25/2022 | Approved | ANTHONY EGSON |
| Interior/Exterior Lathing | 2/25/2022 | Approved | ANTHONY EGSON |
| Drywall Nailing | 3/3/2022 | Approved | HORACE FULTZ |
| Shower Pan | 3/15/2022 | Approved | ANTHONY EGSON |
| Interior/Exterior Lathing | 3/24/2022 | Approved | ANTHONY EGSON |
| BUILDING-Rough-Frame | 7/7/2022 | Approved | ANTHONY EGSON |
| ELECTRICAL-Final | 7/7/2022 | Approved | ANTHONY EGSON |
| Final | 7/7/2022 | Not Ready for Inspection | ANTHONY EGSON |
| Footing/Foundation/Slab | 7/7/2022 | Approved | ANTHONY EGSON |
| Green Building Final | 7/7/2022 | Corrections Issued | ANTHONY EGSON |
| HVAC-Final | 7/7/2022 | Approved | ANTHONY EGSON |
| PLUMBING-Final | 7/7/2022 | Corrections Issued | ANTHONY EGSON |
| SGSOV-Seismic Gas S/O Valve | 7/7/2022 | SGSOV Not Required | ANTHONY EGSON |
| Smoke Detectors | 7/7/2022 | Approved | ANTHONY EGSON |
| Final | 7/15/2022 | OK to Issue CofO | ANTHONY EGSON |
| Green Building Final | 7/15/2022 | Approved | ANTHONY EGSON |
| HVAC-Final | 7/15/2022 | Approved | ANTHONY EGSON |
| PLUMBING-Final | 7/15/2022 | Approved | ANTHONY EGSON |