14003 W LAKESIDE ST 91342

Certificate Information: 14003 W LAKESIDE ST 91342

Application / Permit
21014-20000-03766
Plan Check / Job No.
B21VN09739
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
19'-6" X 16'-10" ADDITION OF TWO BEDROOMS AND ONE BATHROOM TO THE (E) SFD. ALL WORK PER ENGINEER.
Permit Issued
Issued on 1/10/2022
Issuing Office
Current Status
CofO Issued on 7/12/2022
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 7/26/2021 APPLICANT
Assigned to Plan Check Engineer 7/27/2021 PARISA ZAHABI
Corrections Issued 7/27/2021 PARISA ZAHABI
Applicant returned to address corrections 8/19/2021 PARISA ZAHABI
Plan Check Approved 8/30/2021 PARISA ZAHABI
Building Plans Picked Up 9/1/2021 APPLICANT
Issued 1/10/2022 APPLICANT
CofO in Progress 6/10/2022 JOHN HAYES
Permit Finaled 7/12/2022 MICHAEL SMITH
CofO Issued 7/12/2022 MICHAEL SMITH
Permit Finaled 7/12/2022 MICHAEL SMITH

Permit Application Clearance Information

Miscellaneous Cleared 8/3/2021 MIGUEL GAMBOA
Miscellaneous Cleared 8/3/2021 MIGUEL GAMBOA
Roof/Waste drainage to street Cleared 8/3/2021 DAGOVERTO GUERRERO
Sewer availability Cleared 8/9/2021 DAGOVERTO GUERRERO
Eng Process Fee Ord 176,300 Cleared 8/11/2021 DAGOVERTO GUERRERO

Contact Information

Contractor Sharp Builders; Lic. No.: 950190-B 8432 SHARP AVENUE      SUN VALLEY, CA 91352
Engineer Santos,, Michael Fernandez; Lic. No.: C77657 16202 ORION AVE      CHINO, CA 91708

Inspector Information

KEVIN BERBERYAN, (818) 374-9931 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 1/13/2022 Partial Approval JOHN HAYES
Footing/Foundation/Slab 1/18/2022 Approved JOHN HAYES
BUILDING-Rough-Frame 2/4/2022 Partial Approval JOHN HAYES
Floor/Roof Diaphrgm/Shear Wall 2/4/2022 Partial Approval JOHN HAYES
Green Building Rough 2/4/2022 Not Ready for Inspection JOHN HAYES
BUILDING-Rough-Frame 2/14/2022 Corrections Issued JOHN HAYES
ELECTRICAL-Rough 2/14/2022 Not Ready for Inspection JOHN HAYES
Green Building Rough 2/14/2022 Not Ready for Inspection JOHN HAYES
PLUMBING-Rough 2/14/2022 Not Ready for Inspection JOHN HAYES
Shower Pan 2/14/2022 Not Ready for Inspection JOHN HAYES
BUILDING-Rough-Frame 2/24/2022 Partial Approval JOHN HAYES
ELECTRICAL-Rough 2/24/2022 Not Ready for Inspection JOHN HAYES
Green Building Rough 2/24/2022 Not Ready for Inspection JOHN HAYES
HVAC-Rough 2/24/2022 Not Ready for Inspection JOHN HAYES
PLUMBING-Rough 2/24/2022 Not Ready for Inspection JOHN HAYES
Shower Pan 2/24/2022 Not Ready for Inspection JOHN HAYES
Interior/Exterior Lathing 3/3/2022 Partial Approval JOHN HAYES
Rough-Elec/Plmb/HVAC 3/3/2022 Corrections Issued JOHN HAYES
ELECTRICAL-Rough 3/11/2022 Not Ready for Inspection JOHN HAYES
PLUMBING-Rough 3/11/2022 Not Ready for Inspection JOHN HAYES
BUILDING-Rough-Frame 3/29/2022 Approved JOHN HAYES
Green Building Rough 3/29/2022 Approved JOHN HAYES
Rough-Elec/Plmb/HVAC 3/29/2022 Approved JOHN HAYES
Insulation 4/1/2022 Approved JOHN HAYES
Shower Pan 4/1/2022 Approved JOHN HAYES
Drywall Nailing 4/6/2022 Approved JOHN HAYES
Interior/Exterior Lathing 4/6/2022 Approved JOHN HAYES
Final 5/12/2022 Corrections Issued JOHN HAYES
Green Building Final 5/12/2022 Not Ready for Inspection JOHN HAYES
SGSOV-Seismic Gas S/O Valve 5/12/2022 SGSOV Not Ready JOHN HAYES
Smoke Detectors 5/12/2022 Not Ready for Inspection JOHN HAYES
Final 5/26/2022 Corrections Issued JOHN HAYES
Green Building Final 5/26/2022 Not Ready for Inspection JOHN HAYES
SGSOV-Seismic Gas S/O Valve 5/26/2022 SGSOV Not Ready JOHN HAYES
Smoke Detectors 5/26/2022 Not Ready for Inspection JOHN HAYES
Final 6/9/2022 OK to Issue CofO JOHN HAYES
Green Building Final 6/9/2022 Approved JOHN HAYES
SGSOV-Seismic Gas S/O Valve 6/9/2022 SGSOV Approved JOHN HAYES
Smoke Detectors 6/9/2022 Approved JOHN HAYES