7778 N SHADYSPRING PL 91504

Certificate Information: 7778 N SHADYSPRING PL 91504

Application / Permit
21014-20000-03618
Plan Check / Job No.
B21VN09331
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
50' X 18' ADDITION OF A (N) ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33 (c)-(d) AND STORAGE AREA TO (E) DETACHED GARAGE. ALL WORK PER WFPP.
Permit Issued
Issued on 11/24/2021
Issuing Office
Valley
Current Status
CofO Issued on 9/13/2022
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 7/16/2021 APPLICANT
Assigned to Plan Check Engineer 7/23/2021 SERGIO MUNIZ
Corrections Issued 7/24/2021 SERGIO MUNIZ
Applicant returned to address corrections 11/9/2021 SERGIO MUNIZ
Plan Check Approved 11/22/2021 SERGIO MUNIZ
Building Plans Picked Up 11/22/2021 APPLICANT
Issued 11/24/2021 APPLICANT
CofO in Progress 8/16/2022 DAVID ANDERSON
CofO Issued 9/13/2022 MICHAEL SMITH
Permit Finaled 9/13/2022 MICHAEL SMITH

Permit Application Clearance Information

Address approval Cleared 8/4/2021 CARLOS AGUILERA
Eng Process Fee Ord 176,300 Cleared 8/10/2021 CARLOS AGUILERA
Sewer availability Cleared 8/10/2021 CARLOS AGUILERA
Hydrant and Access approval Cleared 8/18/2021 MATTHEW CRAIG
Low Impact Development Cleared 9/24/2021 KHAING AYE
Roof/Waste drainage to street Cleared 9/28/2021 CARLOS AGUILERA
Construction near power lines Cleared 10/25/2021 RIDWAN HARDY
GPI Written Notices Cleared 11/21/2021 BRIAN MILLER
Grading Pre-Inspection Cleared 11/21/2021 BRIAN MILLER

Contact Information

Contractor Owner-Builder       ,

Inspector Information

MATTHEW NELSON, (818) 374-1168 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 1/4/2022 Partial Approval DAVID MATSON
Sewer 1/4/2022 Not Ready for Inspection DAVID MATSON
Excavation/Setback/Form/Re-Bar 1/12/2022 Approved MATTHEW NELSON
Sewer 1/24/2022 Approved CHRISTOPHER DELLEFIELD
Underground Mechanical 1/24/2022 Approved CHRISTOPHER DELLEFIELD
Floor/Roof Diaphrgm/Shear Wall 2/1/2022 Partial Approval MATTHEW NELSON
Green Building Rough 2/1/2022 Not Ready for Inspection MATTHEW NELSON
MERV13>=Rough 2/1/2022 Not Ready for Inspection MATTHEW NELSON
BUILDING-Rough-Frame 2/28/2022 Approved MATTHEW NELSON
ELECTRICAL-Rough 2/28/2022 Approved MATTHEW NELSON
Green Building Rough 2/28/2022 Approved MATTHEW NELSON
HVAC-Rough 2/28/2022 Approved MATTHEW NELSON
MERV13>=Rough 2/28/2022 Approved MATTHEW NELSON
PLUMBING-Rough 2/28/2022 Approved MATTHEW NELSON
Interior/Exterior Lathing 3/10/2022 Conditional Approval CHRISTOPHER DELLEFIELD
Drywall Nailing 3/18/2022 Corrections Issued WILLIAM WREN
Insulation 3/18/2022 Approved WILLIAM WREN
Drywall Nailing 3/23/2022 Approved CHRISTOPHER DELLEFIELD
Interior/Exterior Lathing 3/23/2022 Approved CHRISTOPHER DELLEFIELD
Shower Pan 3/29/2022 Approved ASHLEY THOMPSON
Final 7/29/2022 Corrections Issued DAVID ANDERSON
Footing/Foundation/Slab 7/29/2022 Approved DAVID ANDERSON
Green Building Final 7/29/2022 Corrections Issued DAVID ANDERSON
MERV13>=Final 7/29/2022 Not Ready for Inspection DAVID ANDERSON
SGSOV-Seismic Gas S/O Valve 7/29/2022 SGSOV Approved DAVID ANDERSON
Smoke Detectors 7/29/2022 Approved DAVID ANDERSON
ELECTRICAL-Final 8/4/2022 Corrections Issued DAVID ANDERSON
ELECTRICAL-Final 8/5/2022 Not Ready for Inspection DAVID ANDERSON
Final 8/5/2022 Not Ready for Inspection DAVID ANDERSON
Green Building Final 8/5/2022 Not Ready for Inspection DAVID ANDERSON
MERV13>=Final 8/5/2022 Not Ready for Inspection DAVID ANDERSON
ELECTRICAL-Final 8/9/2022 Approved DAVID ANDERSON
Final 8/15/2022 OK to Issue CofO DAVID ANDERSON
Green Building Final 8/15/2022 Approved DAVID ANDERSON
MERV13>=Final 8/15/2022 Approved DAVID ANDERSON