17916 W ERWIN ST 91316
Certificate Information: 17916 W ERWIN ST 91316
- Application / Permit
- 21014-20000-03254
- Plan Check / Job No.
- B21VN08233
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- PROPOSED 29'-6" X 31' IRREGULAR SHAPED ADDITION AND REMODEL TO (E) SFD. ALL WORK PER ENGINEERING.
- Permit Issued
- Issued on 11/29/2021
- Issuing Office
- Current Status
- Issued on 11/29/2021
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 6/25/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 6/25/2021 | RAPHAEL ROSAS |
| Corrections Issued | 6/26/2021 | RAPHAEL ROSAS |
| Applicant returned to address corrections | 10/28/2021 | RAPHAEL ROSAS |
| Applicant returned to address corrections | 11/17/2021 | RAPHAEL ROSAS |
| Issued | 11/29/2021 | APPLICANT |
| Building Plans Picked Up | 11/30/2021 | APPLICANT |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 8/5/2021 | GABRIEL ROBLES |
| "T" removal | Cleared | 10/5/2021 | STEVEN WECHSLER |
| Miscellaneous | Cleared | 10/5/2021 | STEVEN WECHSLER |
| ZI | Cleared | 10/5/2021 | STEVEN WECHSLER |
| Roof/Waste drainage to street | Cleared | 11/18/2021 | CARLOS AGUILERA |
| Sewer availability | Cleared | 11/20/2021 | CARLOS AGUILERA |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Yenjai,, Seree; Lic. No.: C73151 | 3249 SHADYLAWN DRIVE DUARTE, CA 91010 |
Inspector Information
| JON MCHUGH, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
| IVAN SARABIA, (818) 774-4348 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 12/10/2021 | Approved | SEAN HAUPT |
| Special/Order Compliance | 12/14/2021 | No Access for Inspection | SEAN HAUPT |
| Floor/Roof Diaphrgm/Shear Wall | 12/16/2021 | Partial Approval | SEAN HAUPT |
| Insulation | 12/16/2021 | Not Ready for Inspection | SEAN HAUPT |
| PLUMBING-Rough | 12/16/2021 | Approved | SEAN HAUPT |
| Underground Mechanical | 12/16/2021 | Approved | SEAN HAUPT |
| Wood Frame | 12/16/2021 | Approved | SEAN HAUPT |
| Floor/Roof Diaphrgm/Shear Wall | 1/18/2022 | Corrections Issued | SEAN HAUPT |
| Rough-Elec/Plmb/HVAC | 1/18/2022 | Not Ready for Inspection | SEAN HAUPT |
| Wood Frame | 1/18/2022 | Corrections Issued | SEAN HAUPT |
| BUILDING-Rough-Frame | 1/20/2022 | Approved | SEAN HAUPT |
| Green Building Rough | 1/20/2022 | Not Ready for Inspection | SEAN HAUPT |
| Insulation | 1/20/2022 | Not Ready for Inspection | SEAN HAUPT |
| Insulation | 1/24/2022 | Approved | SEAN HAUPT |
| Interior/Exterior Lathing | 1/24/2022 | Approved | SEAN HAUPT |
| Drywall Nailing | 1/28/2022 | Approved | ROBERT GOLD |
| Interior/Exterior Lathing | 1/28/2022 | Not Ready for Inspection | ROBERT GOLD |
| Shower Pan | 1/28/2022 | Approved | ROBERT GOLD |
| Interior/Exterior Lathing | 1/31/2022 | Approved | JUSTIN HAWLEY |
| Shower Pan | 1/31/2022 | Approved | JUSTIN HAWLEY |
| BUILDING-Rough-Frame | 3/31/2022 | Approved | SEAN HAUPT |
| Final | 3/31/2022 | Corrections Issued | SEAN HAUPT |
| Green Building Final | 3/31/2022 | Not Ready for Inspection | SEAN HAUPT |
| Green Building Rough | 3/31/2022 | Approved | SEAN HAUPT |
| PLUMBING-Final | 3/31/2022 | Corrections Issued | SEAN HAUPT |
| SGSOV-Seismic Gas S/O Valve | 3/31/2022 | SGSOV Not Ready | SEAN HAUPT |
| Smoke Detectors | 3/31/2022 | Approved | SEAN HAUPT |