12654 W COLLINS ST 91607

Certificate Information: 12654 W COLLINS ST 91607

Application / Permit
21014-20000-02240
Plan Check / Job No.
B21VN05506
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
CONVERT (E) 5'-5" X 19'8.5" PORTION OF GARAGE TO SFD AND 13'-8.5" X 20' ADDITION AND REMODEL TO (E) SFD. ALL WORK PER ENGINEERING.
Permit Issued
Issued on 10/12/2021
Issuing Office
Current Status
CofO Issued on 5/3/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 5/4/2021 APPLICANT
Assigned to Plan Check Engineer 5/12/2021 RAPHAEL ROSAS
Corrections Issued 5/12/2021 RAPHAEL ROSAS
Plan Check Approved 10/3/2021 RAPHAEL ROSAS
Building Plans Picked Up 10/6/2021 APPLICANT
Issued 10/12/2021 APPLICANT
CofO in Progress 10/21/2022 ROBERT GOLD
No Progress 1/6/2023 CHRISTOPHER DELLEFIELD
CofO in Progress 5/3/2023 JUAN VALENZUELA
CofO Issued 5/3/2023 MICHAEL SMITH
Permit Finaled 5/3/2023 MICHAEL SMITH

Permit Application Clearance Information

Low Impact Development Cleared 9/18/2021 TA ANH
Roof/Waste drainage to street Cleared 9/20/2021 ABDULLAH SADOZAI
Sewer availability Cleared 9/20/2021 GABRIEL ROBLES
Eng Process Fee Ord 176,300 Cleared 9/21/2021 GABRIEL ROBLES

Contact Information

Contractor All Concepts Construction Inc; Lic. No.: 908070-B 35277 RED ROVER MINE ROAD      ACTON, CA 93510
Engineer Warling,, Jeffrey Paul; Lic. No.: C43743 1792 PEREGRINE CT      SIMI VALLEY, CA 93065

Inspector Information

WAYNE REGESTER, (818) 374-1164 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 11/2/2021 Conditional Approval CHRISTOPHE COCHRAN
Footing/Foundation/Slab 11/8/2021 Approved MATT KELLERMAN
BUILDING-Rough-Frame 11/17/2021 Partial Approval CHRISTOPHE COCHRAN
Drywall Nailing 11/22/2021 Not Ready for Inspection CHRISTOPHE COCHRAN
Floor/Roof Diaphrgm/Shear Wall 11/22/2021 Partial Approval CHRISTOPHE COCHRAN
Footing/Foundation/Slab 12/9/2021 Approved CHRISTOPHE COCHRAN
Green Building Rough 12/9/2021 Approved CHRISTOPHE COCHRAN
Floor/Roof Diaphrgm/Shear Wall 12/27/2021 Partial Approval CHRISTOPHE COCHRAN
ELECTRICAL-Rough 2/8/2022 Approved CHRISTOPHE COCHRAN
HVAC-Rough 2/8/2022 Approved CHRISTOPHE COCHRAN
PLUMBING-Rough 2/8/2022 Not Ready for Inspection CHRISTOPHE COCHRAN
Insulation 2/17/2022 Not Ready for Inspection CHRISTOPHE COCHRAN
BUILDING-Rough-Frame 2/28/2022 Approved CHRISTOPHE COCHRAN
Insulation 2/28/2022 Approved CHRISTOPHE COCHRAN
Drywall Nailing 3/9/2022 Approved CHRISTOPHE COCHRAN
Interior/Exterior Lathing 3/9/2022 Not Ready for Inspection CHRISTOPHE COCHRAN
Interior/Exterior Lathing 3/23/2022 Partial Approval CHRISTOPHE COCHRAN
Interior/Exterior Lathing 5/9/2022 Partial Approval CHRISTOPHE COCHRAN
Final 6/29/2022 Corrections Issued RAFAEL CORTES
Green Building Final 6/29/2022 Not Ready for Inspection RAFAEL CORTES
SGSOV-Seismic Gas S/O Valve 6/29/2022 SGSOV Approved RAFAEL CORTES
Smoke Detectors 6/29/2022 Approved RAFAEL CORTES
Final 7/13/2022 Not Ready for Inspection RAFAEL CORTES
Green Building Final 7/13/2022 Not Ready for Inspection RAFAEL CORTES
Final 10/20/2022 OK to Issue CofO ROBERT GOLD
Green Building Final 10/20/2022 Approved ROBERT GOLD
Pre-Inspection 1/6/2023 Corrections Issued CHRISTOPHER DELLEFIELD
Floor/Roof Diaphrgm/Shear Wall 3/16/2023 Approved KIRK SANDERS