12237 N LOUISE AVE 91344
Certificate Information: 12237 N LOUISE AVE 91344
- Application / Permit
- 21014-20000-02019
- Plan Check / Job No.
- B21VN04895
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- MAJOR REMODEL WITH 1ST & 2ND STORY ADDITIONS TO (E) SFD/GARAGE TO MAKE OVERALL BUILDING DIMENSIONS 57'-6" X 57'6". NFPA 13 D FIRE SPRINKLERS REQUIRED THROUGHOUT.
- Permit Issued
- Issued on 12/13/2022
- Issuing Office
- Valley
- Current Status
- CofO Issued on 5/9/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 5/3/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 6/3/2021 | MARVEL DELACRUZ |
| Corrections Issued | 6/10/2021 | MARVEL DELACRUZ |
| Quality Review Completed | 6/18/2021 | STEVEN KIM |
| Building Plans Picked Up | 6/28/2021 | APPLICANT |
| Applicant returned to address corrections | 6/1/2022 | RAPHAEL ROSAS |
| Plan Check Approved | 12/13/2022 | MARVEL DELACRUZ |
| Issued | 12/13/2022 | APPLICANT |
| CofO in Progress | 5/7/2025 | STEVEN BACK |
| CofO Issued | 5/9/2025 | JOHN JANSON |
| Permit Finaled | 5/9/2025 | JOHN JANSON |
Permit Application Clearance Information
| Distance to fire station | Cleared | 11/18/2021 | KURT CORRAL |
| Hydrant and Access approval | Cleared | 11/18/2021 | KURT CORRAL |
| BHO/Hillside ordinance | Cleared | 4/19/2022 | CARLOS AGUILERA |
| BHO/Hillside ordinance | Cleared | 4/19/2022 | CARLOS AGUILERA |
| BHO/Hillside ordinance | Cleared | 4/19/2022 | CARLOS AGUILERA |
| BHO/Hillside ordinance | Cleared | 4/19/2022 | CARLOS AGUILERA |
| BHO/Hillside ordinance | Cleared | 4/19/2022 | CARLOS AGUILERA |
| Low Impact Development | Cleared | 4/19/2022 | LONDY ALVARADO |
| Eng Process Fee Ord 176,300 | Cleared | 4/20/2022 | CARLOS AGUILERA |
| Grading Pre-Inspection | Cleared | 4/20/2022 | BRIAN MILLER |
| Sewer availability | Cleared | 4/20/2022 | CARLOS AGUILERA |
| Roof/Waste drainage to street | Cleared | 5/10/2022 | CARLOS AGUILERA |
| Green Code | Cleared | 10/4/2022 | MARVEL DELACRUZ |
| GPI Written Notices | Cleared | 12/1/2022 | MARVEL DELACRUZ |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Yenjai,, Seree; Lic. No.: C73151 | 3249 SHADYLAWN DRIVE DUARTE, CA 91010 |
Inspector Information
| JEFFREY PARD, (818) 774-4312 | Office Hours: 7:00-8:00 AM MON-FRI |
| STEVEN BACK, (818) 774-4312 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 4/20/2023 | Conditional Approval | STEVEN BACK |
| Footing/Foundation/Slab | 4/27/2023 | Partial Approval | DAVID SCANTLIN |
| Deputy Reinf. Concrete | 4/28/2023 | Approved | JEFFREY PARD |
| Footing/Foundation/Slab | 5/16/2023 | Not Ready for Inspection | SEAN WIRCH |
| Footing/Foundation/Slab | 5/17/2023 | Approved | JEFFREY PARD |
| Deputy Steel/Welding | 5/25/2023 | Approved | JEFFREY PARD |
| Floor/Roof Diaphrgm/Shear Wall | 6/26/2023 | Partial Approval | DAVID SCANTLIN |
| Floor/Roof Diaphrgm/Shear Wall | 12/11/2023 | Corrections Issued | STEVEN BACK |
| Deputy Wood Construction | 1/23/2024 | Conditional Approval | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 1/26/2024 | Corrections Issued | STEVEN BACK |
| ELECTRICAL-Rough | 4/24/2024 | Approved | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 4/24/2024 | Corrections Issued | STEVEN BACK |
| HVAC-Rough | 4/24/2024 | Corrections Issued | STEVEN BACK |
| PLUMBING-Rough | 4/24/2024 | Approved | STEVEN BACK |
| BUILDING-Rough-Frame | 5/6/2024 | Corrections Issued | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 5/6/2024 | Approved | STEVEN BACK |
| Green Building Rough | 5/6/2024 | Approved | STEVEN BACK |
| HVAC-Rough | 5/6/2024 | Approved | STEVEN BACK |
| Verify Sprinkler Sign Off | 5/6/2024 | Approved | STEVEN BACK |
| BUILDING-Rough-Frame | 5/13/2024 | Approved | STEVEN BACK |
| Interior/Exterior Lathing | 5/13/2024 | Partial Approval | STEVEN BACK |
| Insulation | 5/20/2024 | Approved | DAVID SCANTLIN |
| Drywall Nailing | 5/31/2024 | Approved | CHRIS CHRISTENSEN |
| Interior/Exterior Lathing | 7/3/2024 | Partial Approval | CHRIS CHRISTENSEN |
| Shower Pan | 7/3/2024 | Approved | CHRIS CHRISTENSEN |
| Sewer | 12/17/2024 | Approved | STEVEN BACK |
| Underground Mechanical | 12/17/2024 | Approved | STEVEN BACK |
| Final | 4/21/2025 | Corrections Issued | STEVEN BACK |
| Green Building Final | 4/21/2025 | Approved | STEVEN BACK |
| SGSOV-Seismic Gas S/O Valve | 4/21/2025 | SGSOV Not Ready | STEVEN BACK |
| Smoke Detectors | 4/21/2025 | Approved | STEVEN BACK |
| Final | 5/7/2025 | OK to Issue CofO | STEVEN BACK |
| SGSOV-Seismic Gas S/O Valve | 5/7/2025 | SGSOV Approved | STEVEN BACK |