8115 N GLADE AVE 91304

Certificate Information: 8115 N GLADE AVE 91304

Application / Permit
21014-20000-01620
Plan Check / Job No.
B21VN03879
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
14' X 29' IRR.-SHAPE PATIO COVER ADDITION TO REAR OF (E) SFD. ALL WORK DONE PER WFPP AND LADBS INFORMATION BULLETIN.
Permit Issued
Issued on 6/15/2021
Issuing Office
Current Status
CofO Issued on 12/14/2021
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 4/1/2021 APPLICANT
Assigned to Plan Check Engineer 4/5/2021 GURUNATH NESARAJAH
Corrections Issued 4/5/2021 GURUNATH NESARAJAH
Applicant returned to address corrections 5/21/2021 GURUNATH NESARAJAH
Plan Check Approved 6/4/2021 GURUNATH NESARAJAH
Building Plans Picked Up 6/8/2021 APPLICANT
Issued 6/15/2021 APPLICANT
CofO in Progress 12/13/2021 STEVEN BACK
Permit Finaled 12/14/2021 JOHN JANSON
CofO Issued 12/14/2021 JOHN JANSON
Permit Finaled 12/14/2021 JOHN JANSON

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 5/25/2021 CARLOS AGUILERA
Roof/Waste drainage to street Cleared 5/25/2021 CARLOS AGUILERA
ZA Case Cleared 5/25/2021 DANG NGUYEN

Contact Information

Contractor Owner-Builder       ,

Inspector Information

JEFFREY HARTLINE, (818) 774-4320 Office Hours: 7:00-8:00 AM MON-FRI
CHRIS CHRISTENSEN, (818) 774-4320 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 6/23/2021 Approved DAVID STEPANYAN
Wood Frame 7/23/2021 Corrections Issued DAVID STEPANYAN
Floor/Roof Diaphrgm/Shear Wall 8/13/2021 Approved DAVID STEPANYAN
BUILDING-Rough-Frame 8/27/2021 Approved DAVID STEPANYAN
ELECTRICAL-Rough 8/27/2021 Approved DAVID STEPANYAN
Final 12/13/2021 OK to Issue CofO STEVEN BACK
Smoke Detectors 12/13/2021 Approved STEVEN BACK