1033 E AMOROSO PL 90291
Certificate Information: 1033 E AMOROSO PL 90291
- Application / Permit
- 21014-20000-00914
- Plan Check / Job No.
- B21VN02312
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 10'-3" X 9' AND 12'-6" X 22" ADDITION TO EXISTING SINGLE FAMILY DWELLING; INTERIOR REMODEL; REROOF PORTION OF EXISTING ROOF
- Permit Issued
- Issued on 2/25/2022
- Issuing Office
- Current Status
- CofO Issued on 7/24/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 3/1/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 3/18/2021 | SELLA BENYAMIN |
| Corrections Issued | 3/25/2021 | SELLA BENYAMIN |
| Quality Review Completed | 3/26/2021 | STEVEN KIM |
| Plan Check Approved | 1/13/2022 | SELLA BENYAMIN |
| Issued | 2/25/2022 | APPLICANT |
| Building Plans Picked Up | 3/7/2022 | APPLICANT |
| CofO in Progress | 7/20/2023 | EVAN COOPER |
| Permit Finaled | 7/24/2023 | DANIEL ORRANTE |
| CofO Issued | 7/24/2023 | DANIEL ORRANTE |
| Permit Finaled | 7/24/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| Sewer availability | Cleared | 6/29/2021 | ANTHONY MAINEZ |
| Eng Process Fee Ord 176,300 | Cleared | 6/30/2021 | ANTHONY MAINEZ |
| Low Impact Development | Cleared | 12/6/2021 | LONDY ALVARADO |
| Roof/Waste drainage to street | Cleared | 12/13/2021 | TRACY TATE |
Contact Information
| Contractor | Pacific Design Build Llc; Lic. No.: 1067229-B | 4640 ADMIRALTY WAY STE 500 MARINA DEL REY, CA 90292 |
| Engineer | Lu,, Ining; Lic. No.: S3042 | 47 E LAS FLORES AVENUE ARCADIA, CA 91006 |
Inspector Information
| RUBEN RIVAS, (310) 914-3981 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 3/29/2022 | Not Ready for Inspection | JOHNNY MIRANDA |
| Footing/Foundation/Slab | 3/29/2022 | Not Ready for Inspection | JOHNNY MIRANDA |
| Excavation/Setback/Form/Re-Bar | 4/1/2022 | No Access for Inspection | ANDREW NAVE |
| Deputy Drilled-In Anchors | 4/6/2022 | No Access for Inspection | DAVID FEILER |
| Excavation/Setback/Form/Re-Bar | 4/8/2022 | Approved | DAVID FEILER |
| Footing/Foundation/Slab | 4/8/2022 | Approved | DAVID FEILER |
| ELECTRICAL-Rough | 6/27/2022 | Corrections Issued | DAVID FEILER |
| HVAC-Rough | 6/27/2022 | Corrections Issued | DAVID FEILER |
| PLUMBING-Rough | 6/27/2022 | Corrections Issued | DAVID FEILER |
| ELECTRICAL-Rough | 7/5/2022 | Approved | DAVID FEILER |
| HVAC-Rough | 7/5/2022 | Approved | DAVID FEILER |
| PLUMBING-Rough | 7/5/2022 | Not Ready for Inspection | DAVID FEILER |
| BUILDING-Rough-Frame | 7/12/2022 | Corrections Issued | DAVID FEILER |
| Green Building Rough | 7/12/2022 | Not Ready for Inspection | DAVID FEILER |
| PLUMBING-Rough | 7/12/2022 | Approved | DAVID FEILER |
| Deputy Wood Construction | 7/14/2022 | Conditional Approval | DAVID FEILER |
| BUILDING-Rough-Frame | 9/22/2022 | No Access for Inspection | DAVID FEILER |
| Green Building Rough | 9/22/2022 | No Access for Inspection | DAVID FEILER |
| Wood Frame | 9/22/2022 | No Access for Inspection | DAVID FEILER |
| Pre-Inspection | 9/23/2022 | Not Ready for Inspection | DAVID FEILER |
| Wood Frame | 9/23/2022 | Not Ready for Inspection | DAVID FEILER |
| BUILDING-Rough-Frame | 9/27/2022 | Corrections Issued | DAVID FEILER |
| Floor/Roof Diaphrgm/Shear Wall | 9/27/2022 | Approved | DAVID FEILER |
| Deputy Wood Construction | 9/29/2022 | No Access for Inspection | DAVID FEILER |
| BUILDING-Rough-Frame | 11/2/2022 | Not Ready for Inspection | DAVID FEILER |
| Green Building Rough | 11/2/2022 | Not Ready for Inspection | DAVID FEILER |
| Interior/Exterior Lathing | 11/2/2022 | Not Ready for Inspection | DAVID FEILER |
| BUILDING-Rough-Frame | 11/7/2022 | Partial Approval | DAVID FEILER |
| Green Building Rough | 11/7/2022 | Corrections Issued | DAVID FEILER |
| Interior/Exterior Lathing | 11/7/2022 | Not Ready for Inspection | DAVID FEILER |
| BUILDING-Rough-Frame | 11/8/2022 | Not Ready for Inspection | ANDREW NAVE |
| Green Building Rough | 11/8/2022 | Approved | ANDREW NAVE |
| Interior/Exterior Lathing | 11/8/2022 | Partial Approval | ANDREW NAVE |
| Insulation | 11/14/2022 | Approved | DAVID FEILER |
| Shower Pan | 11/14/2022 | Not Ready for Inspection | DAVID FEILER |
| Interior/Exterior Lathing | 11/16/2022 | Not Ready for Inspection | DAVID FEILER |
| Shower Pan | 11/16/2022 | Approved | DAVID FEILER |
| Drywall Nailing | 11/18/2022 | Approved | DAVID FEILER |
| Interior/Exterior Lathing | 11/18/2022 | Not Ready for Inspection | DAVID FEILER |
| Interior/Exterior Lathing | 11/22/2022 | Approved | HERBERT GIRON |
| BUILDING-Rough-Frame | 11/28/2022 | Corrections Issued | DAVID FEILER |
| ELECTRICAL-Rough | 11/28/2022 | Not Ready for Inspection | DAVID FEILER |
| Green Building Rough | 11/28/2022 | Not Ready for Inspection | DAVID FEILER |
| BUILDING-Rough-Frame | 12/5/2022 | Approved | EVAN COOPER |
| ELECTRICAL-Rough | 12/5/2022 | Approved | EVAN COOPER |
| Green Building Rough | 12/5/2022 | Approved | EVAN COOPER |
| Special/Order Compliance | 12/5/2022 | Partial Inspection | JEREMY TODD |
| Final | 2/3/2023 | Not Ready for Inspection | EVAN COOPER |
| Green Building Final | 2/3/2023 | Not Ready for Inspection | EVAN COOPER |
| SGSOV-Seismic Gas S/O Valve | 2/3/2023 | SGSOV Approved | EVAN COOPER |
| Smoke Detectors | 2/3/2023 | Not Ready for Inspection | EVAN COOPER |
| Final | 2/9/2023 | Corrections Issued | EVAN COOPER |
| Green Building Final | 2/9/2023 | Approved | EVAN COOPER |
| Smoke Detectors | 2/9/2023 | Approved | EVAN COOPER |
| ELECTRICAL-Final | 7/19/2023 | Approved | EVAN COOPER |
| Final | 7/19/2023 | OK to Issue CofO | EVAN COOPER |
| HVAC-Final | 7/19/2023 | Approved | EVAN COOPER |
| PLUMBING-Final | 7/19/2023 | Approved | EVAN COOPER |