11647 W MCCORMICK ST 91601

Certificate Information: 11647 W MCCORMICK ST 91601

Application / Permit
21014-20000-00800
Plan Check / Job No.
B21VN02054
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
NEW 14'-10" x 13'-7" ADDITION TO (E) ONE-STORY SINGLE FAMILY DWELLING, NEW 114 SF DECK IN THE REAR, AND MAJOR REMODEL; ALL WORK PER ENGINEERING DESIGN; AUTOMATIC SPRINKLER SYSTEM IS REQUIRED
Permit Issued
Issued on 5/13/2021
Issuing Office
Current Status
CofO Issued on 10/23/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 2/22/2021 APPLICANT
Assigned to Plan Check Engineer 3/11/2021 SEAN SHAHMIRI
Corrections Issued 3/22/2021 SEAN SHAHMIRI
Quality Review Completed 3/30/2021 OMID HEDAYAT
Applicant returned to address corrections 5/12/2021 SEAN SHAHMIRI
Plan Check Approved 5/12/2021 SEAN SHAHMIRI
Issued 5/13/2021 APPLICANT
CofO in Progress 5/30/2023 JOHN COLEMAN
CofO Issued 10/23/2023 RUBEN SALAS
Permit Finaled 10/23/2023 RUBEN SALAS

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 3/18/2021 GABRIEL ROBLES
Roof/Waste drainage to street Cleared 3/18/2021 GABRIEL ROBLES
Sewer availability Cleared 3/18/2021 GABRIEL ROBLES
Specific Plan Cleared 4/20/2021 CORREY KITCHENS

Contact Information

Contractor Owner-Builder       ,
Engineer Zolfaghari,, Saeed; Lic. No.: C86761 6201 BEE AVE      AGOURA HILLS, CA 91301

Inspector Information

JAVIER RAMOS JR, (818) 374-1163 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 6/14/2021 Approved THOMAS FINNILA
Excavation/Setback/Form/Re-Bar 6/24/2021 Not Ready for Inspection THOMAS FINNILA
Excavation/Setback/Form/Re-Bar 6/29/2021 Corrections Issued THOMAS FINNILA
BUILDING-Rough-Frame 7/16/2021 Partial Approval THOMAS FINNILA
Footing/Foundation/Slab 7/16/2021 Approved THOMAS FINNILA
Green Building Rough 7/16/2021 Partial Approval THOMAS FINNILA
MERV13>=Rough 7/16/2021 Not Ready for Inspection THOMAS FINNILA
Wood Frame 7/20/2021 Partial Approval THOMAS FINNILA
Floor/Roof Diaphrgm/Shear Wall 8/20/2021 Corrections Issued THOMAS FINNILA
Floor/Roof Diaphrgm/Shear Wall 8/30/2021 Partial Approval THOMAS FINNILA
Pre-Inspection 12/3/2021 Approved THOMAS FINNILA
ELECTRICAL-Rough 12/6/2021 Corrections Issued THOMAS FINNILA
HVAC-Rough 12/6/2021 Conditional Approval THOMAS FINNILA
PLUMBING-Rough 12/6/2021 Approved THOMAS FINNILA
ELECTRICAL-Rough 12/28/2021 Approved THOMAS FINNILA
HVAC-Rough 12/28/2021 Approved THOMAS FINNILA
Wood Frame 12/28/2021 Corrections Issued THOMAS FINNILA
Pre-Inspection 1/3/2022 Conditional Approval THOMAS FINNILA
Insulation 1/21/2022 Approved MISAEL ESPARZA
Drywall Nailing 2/10/2022 Conditional Approval KRISTEN CAUSEY
Green Building Rough 2/10/2022 Conditional Approval KRISTEN CAUSEY
Interior/Exterior Lathing 5/9/2022 Partial Approval THOMAS FINNILA
Interior/Exterior Lathing 5/13/2022 Partial Approval THOMAS FINNILA
Gas Test 6/7/2022 Corrections Issued ARAM AVEDISIAN
Underground Mechanical 6/7/2022 Partial Approval ARAM AVEDISIAN
Underground Mechanical 6/8/2022 Corrections Issued THOMAS FINNILA
Deputy Reinf. Concrete 6/10/2022 Conditional Approval MATT KELLERMAN
SGSOV-Seismic Gas S/O Valve 7/8/2022 SGSOV Not Ready MATT KELLERMAN
ELECTRICAL-Final 7/13/2022 Not Ready for Inspection THOMAS FINNILA
PLUMBING-Final 7/13/2022 Not Ready for Inspection THOMAS FINNILA
BUILDING-Rough-Frame 5/15/2023 Approved JACK KARGODORIAN
Drywall Nailing 5/15/2023 Approved JACK KARGODORIAN
Final 5/15/2023 Corrections Issued JACK KARGODORIAN
Green Building Final 5/15/2023 Approved JACK KARGODORIAN
Green Building Rough 5/15/2023 Approved JACK KARGODORIAN
MERV13>=Final 5/15/2023 Approved JACK KARGODORIAN
MERV13>=Rough 5/15/2023 Approved JACK KARGODORIAN
SGSOV-Seismic Gas S/O Valve 5/15/2023 SGSOV Approved JACK KARGODORIAN
Smoke Detectors 5/15/2023 Approved JACK KARGODORIAN
Final 5/25/2023 OK to Issue CofO JOHN COLEMAN
Pre-Inspection 8/14/2023 Approved JACK KARGODORIAN