11445 N ODESSA AVE 91344
Certificate Information: 11445 N ODESSA AVE 91344
- Application / Permit
- 21014-20000-00303
- Plan Check / Job No.
- B21VN00807
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ADDITION TO EX. SFD FOR NEW BEDROOM AND BATHROOM. WORK PER WFPP.
- Permit Issued
- Issued on 6/15/2023
- Issuing Office
- Valley
- Current Status
- Issued on 6/15/2023
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 2/9/2021 | APPLICANT |
| Assigned to Plan Check Engineer | 2/22/2021 | ROSENDO MEDINA |
| Corrections Issued | 2/23/2021 | ROSENDO MEDINA |
| Plan Check Approved | 5/24/2023 | ROSENDO MEDINA |
| Issued | 6/15/2023 | APPLICANT |
| Building Plans Picked Up | 2/25/2024 | APPLICANT |
Permit Application Clearance Information
| Permit | Cleared | 6/3/2021 | GABRIEL ROBLES |
| Sewer availability | Cleared | 6/3/2021 | GABRIEL ROBLES |
| Eng Process Fee Ord 176,300 | Cleared | 6/22/2021 | ROSE MARIE SMITH |
| Grading Pre-Inspection | Cleared | 10/4/2022 | KIRK LINKLATER |
| Trees in Parkway | Cleared | 3/22/2023 | ADALBERTO VERA |
| Roof/Waste drainage to street | Cleared | 5/1/2023 | CARLOS AGUILERA |
Contact Information
| Contractor | Munoz Carlos Enrique; Lic. No.: 908224-B | 2027 PHILLIPPI STREET SAN FERNANDO, CA 91340 |
Inspector Information
| CHRISTOPHER ROJAS, (818) 374-1160 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 6/27/2023 | Partial Approval | JAVIER RAMOS JR |
| Pre-Inspection | 6/27/2023 | Approved | JAVIER RAMOS JR |
| Deputy Wood Construction | 6/30/2023 | Conditional Approval | JAVIER RAMOS JR |
| Footing/Foundation/Slab | 7/3/2023 | Partial Approval | JAVIER RAMOS JR |
| Pre-Inspection | 7/3/2023 | Approved | JAVIER RAMOS JR |
| ELECTRICAL-Rough | 8/22/2023 | Corrections Issued | JAVIER RAMOS JR |
| Floor/Roof Diaphrgm/Shear Wall | 8/22/2023 | Corrections Issued | JAVIER RAMOS JR |
| PLUMBING-Rough | 8/22/2023 | Corrections Issued | JAVIER RAMOS JR |
| Floor/Roof Diaphrgm/Shear Wall | 8/31/2023 | Partial Approval | JACK KARGODORIAN |
| Gas Test | 8/31/2023 | Approved | JACK KARGODORIAN |
| HVAC-Rough | 8/31/2023 | Approved | JACK KARGODORIAN |
| PLUMBING-Rough | 8/31/2023 | Corrections Issued | JACK KARGODORIAN |
| BUILDING-Rough-Frame | 9/25/2023 | Partial Inspection | JAVIER RAMOS JR |
| ELECTRICAL-Rough | 9/25/2023 | Corrections Issued | JAVIER RAMOS JR |
| PLUMBING-Rough | 9/25/2023 | Approved | JAVIER RAMOS JR |
| ELECTRICAL-Rough | 10/5/2023 | Approved | JAVIER RAMOS JR |
| Insulation | 10/5/2023 | Approved | JAVIER RAMOS JR |
| Interior/Exterior Lathing | 10/5/2023 | Partial Approval | JAVIER RAMOS JR |
| Shower Pan | 10/5/2023 | Approved | JAVIER RAMOS JR |
| BUILDING-Rough-Frame | 11/21/2023 | Approved | JAVIER RAMOS JR |
| Drywall Nailing | 11/21/2023 | Approved | JAVIER RAMOS JR |
| Green Building Rough | 11/21/2023 | Approved | JAVIER RAMOS JR |
| ELECTRICAL-Final | 7/1/2024 | Approved | JAVIER RAMOS JR |
| Final | 7/1/2024 | Corrections Issued | JAVIER RAMOS JR |
| HVAC-Final | 7/1/2024 | Corrections Issued | JAVIER RAMOS JR |
| PLUMBING-Final | 7/1/2024 | Approved | JAVIER RAMOS JR |
| SGSOV-Seismic Gas S/O Valve | 7/1/2024 | SGSOV Approved | JAVIER RAMOS JR |
| Smoke Detectors | 7/1/2024 | Approved | JAVIER RAMOS JR |